Skip to the record
The definitive source for everything Noosa Council.

Original source · versioned page text

Application Report

of 157

Page text shows just the words. Original shows the document exactly as it was published.

RECONFIGURATION OF A LOT (1 INTO 5 LOTS)
83 BUTLER STREET, TEWANTIN



 PERFORMANCE OUTCOMES                      ACCEPTABLE OUTCOMES                                PROPOSAL                                       COMPLIANCE
                                           a) a joint application with the adjoining
                                              owner is made; and
                                           b) jetties are constructed as follows—
                                           c) the jetty is shared between two unit
                                              owners;
                                           d) the jetty straddles the common
                                              boundary of the two units;
                                           e) jetty heads and pontoons are not
                                              constructed; and
                                           f)   fencing between the two properties is
                                                setback a minimum 1 metre from the
                                                revetment wall to allow for efficient
                                                access to the jetty by both owners.
                                           AO19.8                                             AO19.8                                         ☐Compliant
                                           Walkways serving jetties have at least one         The proposal does not provide tidal works or   ☒N/A
                                           rigid handrail fitted and the walkway is a         works in a watercourse.                        ☐Performance Solution
                                           minimum width of 750 millimetres and a
                                           maximum width of 1.5 metres where—
                                           a) the walking surface of the jetty is
                                                constructed level with the top of the
                                                revetment wall;
                                           b) water reticulation systems are fitted
                                                with a mechanical backflow prevention
                                                device; and
                                           c) electrical reticulation systems carrying
                                                electricity in excess of 24 volts are not
                                                to extend beyond the revetment wall.
                                           AO19.9                                             AO19.9                                         ☐Compliant
                                           Any lower level platform, or siding, along                                                        ☒N/A
                                           the jetty walkway has a maximum width of


                                                      BRISBANE: P +617 3361 9999 I 57 Manilla Street, EAST BRISBANE Q 4169
                                                  NORTHERN NSW: P +61 2 6637 9110 I Building 1, 1 Porter Street, BYRON BAY N 2481
                                                               E: [email protected] W: www.tpalliance.com.au
Log in to download the original file

Application Report.pdf · 2.0 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.