DRAWING SIZE - A2
ACTION TANKS
3O000Lt DIVERSION
MASTER WATER TANK
OR EQUALY APPROVED
RP BOUNDARY
P|
Lewsa
Eo ae
mm em ee ee me ee a ee ee ee eee eee ee ee ee
DN40 PUMPED DISCHARGE
FROM POOL, CONNECTION
TO GULLIES IN ACCORD.
AS3500.2.2-1996 CL. 10.9
General Notes :
1, Hydraulic services shown are diagramatic only. Refer to architectural
drawings for locations of fixtures.
2. All Sanitary Hydraulics and Water Reticulation within the allotment
boundary to be in accordance with AS3SO0.
3. All work shall comply with the requirements of authorities having LEGEND
prisdiction, after obtaining oll necessary permits ond approvals. B Bath
4. The contractor is to confirm the position of oll existing services as co Clean-Out
indicated on these and associated plons prior to the commencing of op Rainwater Down-Pipe
work, Eu Expansion Joint
5. Stormwater drainage pipes to 2259 shall be Class SW uPVC HEAVY FP Frog Flop
(U.N.0.) pipe. Over 225¢ Concrete Rubber Ring Joint (RRJ) Class 3. All FWG Floor Waste Gully
pipes U.N.O. to be laid at a minimum grade of 1 in 100 U.N.O, Joins are = HE Hose Cock
to be constructed in accordonce with the manufacturers requirements. HCB House Connection Branch
6. Sewers 100mm diam. uPVC DWV (U.N.O.) and laid ot 0 minimum HR 36m Fire Hose Reel
grade of 1 in 60. HWU = Hot Water Unit
7. Water supply pipework below ground is to be : Ic inspection Chomber
63mm diam. or less ~ High Density Type 50 tL lovert Level
Class 12 Polyethylene 10 Inspection Opening
Copper. oo nv . a ur Laundry Tub
9. Water services ore not permitted in ground stabs and all joins and NRV — Non=Return Valve
connections shall be made above the slob. ORG — Overflow Relief Gully
PLY Pressure Limiting Valve
10. Fire Hydrants are to be instolled are to be installed in accordance
with AS2419.1. Hose Reels are to be installed in accordance with AS24413 Stop Cock
11. Clean-outs, Inspection openings and Closing caps situated in SHR crower
vehicular or pedestrian pavements ore to be fitted with either bross or x ace Level
casi-iron covers. 1G Test Gote
12. Alf in-ground volves shall be in accordence in approved concrete v Vent
path boxes, ; ; . VB Vonity Basin
13. All waste pipes ond water services penetroting slabs to be wrapped ve Vent Cowl
in on approved flexible joint joint wropping. WC Water Closet
14. The term "SERWICE' refers to the minimum internal pipe diameter
unless noted otherwise.
We Washing Machine
pls ER hae
BVA VANVANVAN
HWU ON SAFE HWU ON SAFE
TRAY SO WASTE TRAY 50 WASTE
TO GRATED TO GRATED
DRAIN
RCB
AB
<a
pc ered sh, se ore
— -
LILLIE LIP PPI IIIA RT IIL OL
SUSPEND S/W PIPES FROM SLAB
SOFFIT, DROP BELOW RCB’s
"RP BOUNDARY
SITE PLAN ~ STORMWATER & WATER SUPPLY
SCALE 1: 100
Ziel |
CARICA SECT = A= A
DETALS
As per plon
Flow
As per plon
. MANAGEMENT PLAN
Slotted Agg pipe ~ Ensure the inflow into
150 min clearance on ieepraved Heal ond sill guord. Sobr
7 Hh
to base. As per plan 20mm cleon ope et, ‘stopped in geotobric cloth os
aggregate fully — - The pit should be bockflushed on o regulor
(KN encased in (3 months) to remove ony sits or simifior
=) geofabric. materials.
~ The pit should only be used for the disposal of
slarmwotes.
STORMWATER SOAKER PIT DETAIL
the pit is protected with
6.
Revision
A
| I
Description
Soaker pit added, details amended
24,08.06
STORMWATER NON-WORSENING ASSESMENT
WITH UNIT NUMBERS CLEARLY
COCKS
FITTED WH NON RETURN VALVES MARKED.
LOCATION AS PER ARCHITECT ~S
PLUMBED TO WATER TANKS .
ACTION TANKS
3000Lt DIVERSION :
MASTER WATER TANK = i
OR EQUALY APPROVED | :
NEW 32dn WATER
SERVICE BRANCH FROM
COUNCIL MAIN, BY
N.S.C.
12,0m(L) x 1.0m{W) x 1.0m(D)
ISTORMWATER SOAKAGE PIT TO
{DETAIL
\ 1-43.02
ZAATAAANTA
I
weve
i 4(No.) 685x450x408 slot Matrix Drainogé
| Cells wrapped in geofobric, sefer to detail.
GRATED DRAIN
io
1a
c
See ee ee eee ee ee ed
RPD
Lot 287 on RP48111
21 Ferguson street
Sunshine Beach
Site area 536m2
Atlantis MATRIX drainage
cells as specified, wropped
in geofabric
STORMWATER
OUTFLOW
Provide slotted pipe
through MATRIX cells
Sei ped ct op ae ATLANTIS DRAINAGE CELL SOAKER PIT DETAL
rat
E
— Water Meter.
Cat
aoe
UPVC Sewer, size grade and invert
level as noted
—--—-W—--- - External Poly Woter Service, size os noted a he -
e-.
—()
basis
riser locations
—CW¥— - Internal Cold Woter service . Sanitary Stack
~——HW-—-- — - Internal Hot Water service
2/25mm METERS WITH DUAL CHECK
VALVES IN INDIVIDUAL PATH BOXES
— Stormwater pipe, size, grade and invert
levels as noted
Cold and Hot Woter riser
~ Fixture Unit loading.
KERB Pre-Development 25% Impervious Area
ADAPTOR Post Development 80% impervious
Q(100) 5 Minute Storm require 1200It storage.
| 2000! Provided Vio water storage tanks ond
1 Atlontis drrainage cells Driveway runoff disposed
_ of on-site
1 tJ
| lis
1 a
ie}
=z
oS
wn
=>
cS
oc
Li
Le
\
}
13
SSeS oe — KERB vB
ADAPTOR rt
+ 1
3
|
{
\
N SK
I
NI
i PLUMB 10
; WATER TANK
4 INTERNAL WATER SCHEMATIC
NOT TO SCALE
STORMWATER
INFLOW
| 8 CONSTRUCTION
G (ae comsurrina ENGINEERS
9;
Structural - civil - geotechnical
ABN 40 098 487 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634
Title: HYDRAULICS SERVICES
Project 21 Ferguson Street
SUNSHINE BEACH QLD 4567
Date: June 2007 Drg No. 16322-H2
ond size.
number ond Vent size |
3s
5
3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2081 - Response to Information Request Part 2 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.0 MB (small file)
- File type
No other editions are linked here.