DRAWING SIZE 7 A2 A Soaker pit added, details amended 24.08.06

C

 

 

 

[ Cells wrapped in geofobric, refer to detail, i
STORMWATER NON—WORSENING ASSESMENT
wa Feet ——auens oer ene . i. . = Pre-Development 25% Impervious Area
vee oe Ye, Pare Testes t ADAPTOR Post Development 80% impervious
™: VALVES IN INDIVIDUAL PATH BOXES Q(100) 5 Minute Storm require 1200It storage.

WITH UNIT NUMBERS CLEARLY
MARKED.

     
  

 

i
| 2000it Provided Vio water storoge tanks and

\ Atlantis drrainage cells Driveway runoff disposed
| of on-site
}

1

v7
47

   

HOSE COCKS
FITTED WITH NON RETURN VALVES

 
   
 
 
 
  
  
  

     
  
  
 
  

     
 
 

 

   

    
 

   
      
  

 

 

 

 
    

 

 

       
 

LOCATION AS PER ARCHITECT N: 5 _
PLUMBED TO WATER TANKS SI Han
\ td
I
ACTION. TANKS p=
3000Lt DIVERSION = NEW 32dn WATER wm
i HWU ON SAFE HWU ON SAFE MASTER WATER TANK i ! SERVICE BRANCH FROM
TRAY SO WASTE TRAY 50 WASTE OR EQUALY APPROVED | COUNCIL MAIN, BY =
i { ' SO
i 10 GRATED : é TO GRATED i NS.C. Pas
; ie Hg i PI og DRAIN 4 x
i u \ TANK am ae ee a Ge cape hl me oe ee ee Worn ann ZLLZLZLZLILI ZZ ZT 7, | ©
r {
i oy Ee lH t oc
i p | mm me ee te nee rer cat me gt eee ee ee wee oe ce QA QS nn ne ee ee ee
i : _ sens os ZT TT TPT TT Yeon ig 1 nntntertmranened #2.Qm(L) x 1.Gm(W) x 1.0m(D) LJ
i: i) —— 1 | i: once Up = !STORMWATER SOAKAGE PIT 10 to
i : i i : i i $ SA, 908 UPVC (Grated Droin) DETAIL
; f 1 9 / 3000. \ L jDETAL.
i : | V4 1 A WATER | lo 430° SN
i AT it AN RSS IS eee — nee 2,
! , Al 1 =a TANK O/ SASS RE OR vB
i ‘a | | Et LLDPE PLZZ LL AI LEN PELE 1 4
z 1 - | !
2 \ i i rt Az 4(No.) 685x450x408 Atlontis Matrix Drainage :
3} ie I Fy Cells wrapped in geofabric, sefer to detail. \
e I eC :
! As { i
pit Be |
ak j } f FE
| AA ee omer mares ric OP OR JE | -
KO : WILLE Z IDL ILL LOL LOL Le LELTLLILZ LALA LLL LIP TITTTT, r SK
! ' Pont =
hw SUSPEND S/W PIPES FROM SLAB is J
i SOFFIT, DROP BELOW RCB's ig |
me me ae ce ee ae ee eee me eee ee nee ee ee ae ea ee ee ee me a GOS Sa seen Se ca a em ne oe ce ve se ee ne le ce gene ee ceva gc ge ese se se cee gn sep ee pe ye ope eee eves i PLUMB 10
RP BOUNDARY WATER TANK

 

   

  

DN40 PUMPED DISCHARGE
FROM POOL, CONNECTION
TO GULLIES IN ACCORD.

AS3900.2.2-1996 CL. 10.9

RPD
SITE PLAN ~ STORMWATER & WATER SUPPLY Lot 287 on RP4B IN 4 INTERNAL WATER SCHEMATIC

21 Ferguson street
SCALE 1: 100 Sunshine Beach NOT TO SCALE
Site area 536m2

 

 

    
   

General Notes :

1. Hydraulic services shown are diagramatic only. Refer to architectural

 

drawings for locotions of fixtures. . .
2. All Sanitary Hydraulics and Woter Reticulation within the allotment Aventis Seed eee
boundary to be in accordance with AS3500. ¢ : ih , wrapp
3. All work shalt comply with the requirements of authorities having LEGEND in geotabric
risdiction, after obtaining all necessory permits ond approvals. 8 Bath
4. The contractor is to confirm the position of all existing services os co Clean-Out STORMWATER STORMWATER
indicated on these and associated plans prior to the commencing of op Rainwater Down-Pipe OUTFLOW peewee een ene nen en nnn ene nee ene ~ INFLOW
work. tJ Expansion Joint f 1
5. Stormwater drainage pipes to 2259 shall be Class SW uPVC HEAVY FP Frog Flap i }
{U.N.0.) pipe. Over 2250 Concrete Rubber Ring Joint (RRU) Class 3. Alt FWG Floor Waste Gully i i
pipes U.N.O. to be laid at a minimum grade of 1 in 100 U.N.O, Joins are = HC Hose Cock i Jt
4o be constructed in accordonce with the manufacturers requirements. HCB House Connection Branch RR RRR ER mmm RRS SS mn ioreienanenenearetel
6. Sewers 100mm diam. uPVC OW (U.N..) and laid at 0 minimum se en we Hose Reel Provide slotted pipe
grade of 1 in 60. jot water Uni
7. Water supply pipework below ground is to be ; I Inspection [homer Surtace Slotted horizontal through MATRIX cells
. a ‘ invert Level
Bim dam. or less ~ High Density Type 50 i ening Bund Gopped Concrete encased 299 er et ____ ATLANTIS DRAINAGE CELL SOAKER PIT DETAIL _—

    
  

     

        

 

   

      
 
  

 

Is Inspection Shaft
UT Laundry Tub

NRV — Non-Return Volve
ORG Overflow Relief Cully
PLY Pressure Limiting Valve

  
 
 

8. All above ground ond internal water supply pipework to be Type 8
Copper.
9. Water services are not permitted in ground slabs ond all joins and
connections shall be made above the slab.
10. Fire Hydronts ore to be installed are to be installed in accordance

 
  
  
    
  
 

 
  
    
 
           

Led
As per pion

 
   
    
   
 

   
 
  
  
  
  
 
    
     
   
  
  
   

  

(a/A/> CONSULTING ENGINEERS
SCG strwetural - civil - geotechnical

    
 

 

 

  
    
  

      

    
        
     

 

           
  
    
    

     

 

    
      
  
  
  
  

  
  
     

 

 
  
   
  
 

 

 
   
  
   
 

    
   
 

    
 

  
  

 

. , . : SC Stop Cock
with AS2419.1. Hose Reels are to be installed in accordance with AS2441.
11. Clean-outs, Inspection openings and Closing cops situoted in an crower Level s Tet SECTION ~ A ~ A ABN 40 098 481 899
reticular eesti povements are to be fitted with either brass or 5K Sink Flow }: sccm 18 DUKE STREET SUNSHINE BEACH QLD.4567
12. AH in-ground volves shall be in accordance in approved concrete 1 Test Gote Slotted Agg pipe 2 = Ensure’ the inflow into the pit is protected with KEY Ca — Water Meter. Ph (07) 5447 5544 Fax (07) 5447 2634
path boxes v Vent 150 min clearance ‘ on peers | fea ond ai gut «coh
be at . . : vB Vanity Basin to base. ‘Sper plan 20mm clean specified e wrapped in geofobric cloth os ~ UPVC Sewer, size grade and invert cue «= Stormwater pipe, size, grade and invert ta
13, All waste fines ond ater services penetrating slobs to be wrapped ve Vent Cow! aggregate lly i pi shold be bocklushed on o segdr bass level as noted levels as noted Title: HYDRAULICS SERVICES
in Of approved Hexil e joint jor oping. . a we Water Closet (A encased in {3 months) to cemove ony sills or simifier ++ W—----—- — External Poly Water Service, size as noted Cy he - Cold and Hot Water riser ~
14. The term SERVICE refers to the minimum interno! pipe diameter Wat Washing Machine \-/ geofabric. “— should nly be used for the at riser locations and size. Project 21 Ferguson Street
unless noted otherwise. stocewater. —CH— - Internal Cold Water service @- ~ Sanitory Stack number and Vent size x SUNSHINE BEACH QLD 4587
5
STORMWATER SOAKER PIT DETAIL —HW— —- internal Hot Water service —®) — Fixture Unit loading. : Date: June 2007 Drg No. 16322-H2 | *& |

       

Used in these records

About this file

File size
2.0 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2081 - Response to Information Request Part 2 [As Published].pdf · 2.0 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.