ORDINARY MEETING AGENDA                                                       19 JANUARY 2017


                    Table 1

               NOISE LIMITS AT A SENSITIVE RECEPTOR

               PERIOD                   Noise level at noise sensitive place measured as the
                                        adjusted maximum sound pressure level (Lamax, adj,T)

               7am – 6pm                Background noise level (LAbg,T) plus 5 dB(A)

               6pm – 10pm               Background noise level plus 5 dB(A)

               10pm – 7am               Inaudible

               NOISE LEVELS AT COMMERCIAL PLACE

               PERIOD                   Noise level at a commercial place measured as the
                                        adjusted maximum sound pressure level (Lamax, adj,T)

               7am – 6pm                Background noise level (LAbg,T) plus 10 dB(A)

               6pm – 10pm               Background noise level plus10 dB(A)

               10pm – 7am               Background noise level plus 8 dB(A)

        82.   When requested by Council, a Noise Impact Assessment Report (NIAR) showing
              monitoring and recording of noise levels must be undertaken to investigate any
              complaint (other than a frivolous or vexatious complaint) caused by noise
              emissions from operations at the premises.
        83.   Such monitoring must be undertaken within a reasonable and practicable
              timeframe nominated by Council and be performed by a suitably qualified person
              in accordance with accepted guidelines and standards. The report is to be
              submitted to Council detailing the results of such monitoring and
              recommendations for any measures to achieve compliance with limits outlined in
              Table 1 of this Decision Notice.
              For the purpose of measuring and certifying relevant noise conditions and
              reporting (e.g. mechanical plant and equipment, a/c units, motors, refrigeration
              equipment, compressors, pumps, rooftop plant and equipment. etc.) a suitably
              qualified person is either:
              a.    a Registered Professional Engineer of Queensland, or
              b.    an environmental consultant with a minimum of three (3) years current
                    experience in the field of acoustics.
              Rainwater/Detention Tanks
        84.   In accordance with the Public Health Act 2005, rainwater tanks (including the
              detention tank) must be constructed with mosquito proof screens (made from
              either brass, copper, aluminium or stainless steel), and constructed with a mesh
              size of no more than 1mm, and must be installed in a way that does not
              accelerate corrosion. Tanks that contain flap valves must be installed so that
              when closed, mosquitoes cannot pass through the valve.
        85.   Where it is intended to use rainwater for drinking purposes, a suitable treatment
              system is required to be installed to disinfect or treat the water to microbiological
              and physical standards as described in the current Australian Drinking Water
              Guidelines to make it fit for drinking purposes.



                                                                                   Page 17 of 25
Log in to download the original file

2017-01-19 Ordinary Meeting Agenda(PDF, 593KB).pdf · 607 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.