       (a)   whether the waste will be putrescible or dry waste;
       (b)   whether the waste will be recyclable waste; and
       (c)   whether the waste will be heavy or light.

(4)    Waste Generation Rates ­ Refer to SC6.10 ­ Appendix 1 which provides a guide to likely waste generation for various uses.
(5)    Minimum Service Levels – Table SC6.10.5.1 indicates minimum service levels for uses. Council may seek to vary the
       requirements having regard to the size, location and level of occupancy of the use.
(6)    Specialised Waste Storage Bins – SC6.10 ­ Appendix 2 describes two types of specialised waste storage bins available through
       Council’s contractor.
(7)    Size and location of Waste Storage Areas –
       (a)   The following matters will be considered in determining an appropriate size for waste storage areas:
             (i)     Types of waste and storage required:
                     • bins for putrescible waste;
                     • bins for recyclables;
                     • drums for waste cooking oils;
                     • bales for cardboard;
                     • bags or bins for green waste; and
                     • any other specialised waste storage bins needed, eg: medical waste; and
             (ii)    Sufficient space between waste storage bins to allow for maneuvering and washing of bins, where appropriate
                     noting that the bin store must be large enough for the bins to sit next to each other, not behind each other.

       (b)   Adequate lighting needs to be provided to allow the usage of the bin store after dark
       (c)   Internal waste rooms should be well ventilated and have a smooth easily cleanable floor
       (d)   Suitable drainage, with water discharging into a sewer drain, must be installed to allow the washing of bins and a tap with
             hose connection available.
       (e)   Waste storage areas can be roofed or unroofed.
       (f)   Waste storage areas contain bunded and non­bunded areas depending on their size and he type of waste to be stored.
             Where bunded areas are required:
             (i)     waste oil containers must be stored within bunded areas; and
             (ii)    bins must be washed within the bunded area.

                     Advisory Note: Washing bins within bunded areas ­ 240 litre bins should be tipped on their side and washed out to the bunded drain. Bulk bins
                     should be wheeled over the bunded area and washed out by removing the plug from the base of the bin.


(8)    Screening of Waste Storage Areas ­ Waste storage areas are required to be screened and can be attractively designed to
       minimise their visual impact on the streetscape and surrounding areas. Examples exist within our shire of such storage areas.
       Figure SC6.10.1 indicates a storage area designed as a feature wall, with 240 litre bins stored behind the wall and access via
       wooden panel doors.
(9)    Indoor Waste Storage –
       (a)   Waste and waste storage bins must not be placed:
             (i)     where they may impede safe use of any exit, exit corridor, doorway or stairway;
             (ii)    under stairways; or
             (iii)   near any existing or potential heat source.

       (b)   Waste storage bins must be made of non­combustible materials.
       (c)   Indoor waste storage areas must:
             (i)     be well ventilated;
             (ii)    be well lit; and
             (iii)   have “hazardous waste” and “no smoking” signs installed.

       (d)   Figure SC6.10.2 provides an example of an indoor waste storage area.

(10)   Design Standards for Vehicle Access – Within the development site:
       (a)   design specifications must be sufficient to carry a wheel load of 7 tonnes per axle; and
       (b)   turning circles are designed in accordance with AUSTROADS: design single unit truck/bus (12.5 metres) template; and

  **FINAL DRAFT ­ Post Consultation 2019**
                                                                                                                                                         Page 3 of 10
Log in to download the original file

2019-12-11 SM Agenda - Item 1 - Attachment 7 - Final New Noosa Plan - Part 8-10 Schedule Appendix - Clean version(PDF, 22MB).pdf · 23.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.