Skip to the record
Noosa’s premier civic archive.

Original source · versioned page text

2019-12-11 SM Agenda - Item 1 - Attachment 7 - Final New Noosa Plan - Part 8-10 Schedule Appendix - Clean version

of 439

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (23.3 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
1  Channels are included in the pipelines and channels layer SPP IMS but are not differentiated from pipelines. Where an applicant
identifies the bulk water supply infrastructure is a channel rather than a pipe, applicants should contact the utility provider to discuss
appropriate separation distances.
2 Refers to any type of development involving blasting <500 kg charge mass per delay, use of explosives, piling, and other
vibratory/compaction machinery (over 20t centrifugal force) during construction and/or operation. For blasting over 500 kg, applicants are
to contact the asset owner as a greater separation zone may apply.
3 It is recommended that blasting provisions be included in an extractive industry code (or similar).
4 For dam structures and weirs, applicants should contact the utility provider to determine the toe of the dam/weir.
5 Dam/weir height is to be taken at the maximum section of the dam/weir (from dam/weir crest to dam/weir toe).



Table 8.2.9.4          Criteria for assessable development ­ Gas pipeline and Major Electricity Infrastructure

Performance outcomes                                                    Acceptable outcomes

Gas pipeline corridor and buffer area
PO1                                                                     AO1.1
Development, including uses and works are constructed and               Buildings and structures are setback a minimum of 40 metres
operated to avoid:                                                      from a gas pipeline corridor.
(a)     compromising the viability of the gas pipeline corridor; or
                                                                        AO1.2
(b)     damaging or adversely affecting the existing or future
                                                                        The use does not involve the storage of flammable, explosive or
        operation of a gas pipeline within the gas pipeline corridor.
                                                                        other hazardous materials within 200 metres of the gas pipeline
                                                                        corridor.
                                                                        OR

                                                                        AO1.3
                                                                        Written conformation of the pipeline license holder of Petroleum
                                                                        Pipeline License 32 that the setback distance and design of the
                                                                        development does not impact the future use of the gas pipeline.

                                                                        Editor's note­ should a lesser setback distance be proposed, it is
                                                                        recommended that the applicant consult with the relevant gas
                                                                        pipeline manager prior to the lodgement of a development
                                                                        application to determine how compliance with the performance
                                                                        outcome can be achieved.




Performance outcomes                                                    Acceptable outcomes

Major Electricity Infrastructure
PO2
Development does not increase risk to community health or               No acceptable outcome provided
safety, or the operation and reliability of major electricity
infrastructure
PO3                                                                     AO3.1
Development involving a sensitive land use is sufficiently              With the exception of class 10 buildings, buildings associated
separated from major electricity infrastructure and substations to      with a sensitive land use maintain a setback of at least:
minimise the likelihood of nuisance or complaint.                       (a)   50 metres from a transmission substation;
                                                                        (b)   10 metres from any other substation; and
                                                                        (c)   30 metres from a transmission line easement.

                                                                        AO3.2
                                                                        Buildings are not located within an easement for a distribution
                                                                        line.




    **FINAL DRAFT ­ Post Consultation 2019**
                                                                                                                               Page 49 of 51
Log in to download the original file

2019-12-11 SM Agenda - Item 1 - Attachment 7 - Final New Noosa Plan - Part 8-10 Schedule Appendix - Clean version(PDF, 22MB).pdf · 23.3 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.