Skip to the record
The gold standard in government transparency.

Original source · versioned page text

Development Application part 2 OF 2 All of CD, Information in notes - MCU12/0216

of 389

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (36.8 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 205, section 1. The text section number identifies this passage in the reader.

CSR Building Products Limited                                                                                                   Page 21
West Ridge Quarry
Site Based Management Plan


                                            Can provide some degree of turbidity control while the Buffer Zone remains unsaturated.
Sediment Fence –            SF - W          Type 1 sediment trap.
woven fabric                                Suitable for all soil types.
                                            Long duration construction sites likely to experience several storm events.


3.1.4        Monitoring
      The Site Manager shall carry out monthly surveillance of on-site water storages and treatment systems.
      Site inspection of water storages and treatment systems shall be carried out by the Site Manager where practicable
      prior to anticipated runoff-producing rainfall and immediately following the event.
      The inspections should consider:
      -    condition of banks and batters;
      -    condition of inlet and outlet zones, including structure integrity, possible clogging, excessive sediment deposition
           or erosion;
      -    pollutant levels within any treatment devices; and
      -    weed infestation.

      Prior to a release event from the quarry pit voids, the Site Manager shall arrange water samples to be collected for
      laboratory analysis at the monitoring frequency and locations provided in Table 13 – Water Monitoring Frequency
      and Locations.

                                         Table 13 – Water Monitoring Frequency and Locations
        Parameter                            Location           Monitoring Frequency
        Turbidity                            1, 2 and 3
        Suspended Solids                     1, 2 and 3
                                                                Prior to discharge
        pH                                   1, 2 and 3
        Visual Oil & Grease                  1, 2 and 3

      The Site Manager may engage the services of a suitably qualified and experienced person to conduct the water
      quality sampling and review monitoring results to provide advice in relation to the water quality management if a
      complaint is received or if requested by the administrating authority.
      Any surface water sampling will be undertaken in accordance with The Department of Environment and Heritage
      Protection (EHP) Monitoring and Sampling Manual, September 2009 or subsequent editions.

3.1.5        Audit and Review
      The effectiveness of the stormwater, erosion and sediment control management strategies will be reviewed
      periodically and at least once every three years.

3.1.6        Reporting and Responsibility
      Complaints or incidents regarding stormwater are to be reported to the Site Manager as soon as practicable and
      recorded on the complaint register.
      The Site Manager shall maintain a record of surveillance monitoring of on-site water storages and treatment systems,
      of any corrective actions taken and complaints or incidents reported.
      Records including results of any monitoring program undertaken on-site and complaint or incidents will be kept for a
      minimum of five years for inspection by relevant statutory authorities.

3.1.7        Identification of Incident or Failure to Comply
      Significant soil erosion evident within disturbed areas following rainfall events.




December 2012 / file ref. 1271_610_001                                                                               GROUNDWORK p l u s
Log in to download the original file

Development Application part 2 OF 2 All of CD, Information in notes - MCU12_0216.pdf · 36.8 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.