Council archive · source document
Appendix D - Code Assessment · RAL19/0011
O12 Buildings and other works are designed additions of more than 50m2 gross floor
and sited to— area to an existing building or structure, The proposed development is for a boundary realignment only.
a) provide flood free access to premises and floor levels for habitable rooms are—
flood free habitable areas; a) for areas where minimum floor levels are
b) allow only minor, short term and infrequent available—not less than the specified level;
flooding of non-habitable areas; b) for areas where flood modelling is
c) ensure carparking areas can be adequately available—a minimum of 500mm above the
drained; modelled flood level; and
d) ensure drainage does not adversely impact c) for areas where flood modelling is not
upon other premises; and available, a minimum of 500mm above the
e) ensure filling or excavation does not highest known flood level;
adversely impact upon other premises by—
i. causing ponding of water on the site or AND
nearby land; S12.2 Where Council infrastructure is
ii. increasing flooding, which adversely affects available—
the safety or use of any land upstream and a) any drainage (from buildings and land)
downstream; and flows to that infrastructure; and
iii. adversely affecting the flow of water in any b) the infrastructure has the capacity to
overland flow path. accept any additional loading;
AND
S12.3 Car parking and maneuvering areas
are constructed at a level that permits the
parking area to drain from the site by
gravity means, without the need for
mechanical pumping; or
S12.4 Basements for residential uses have
flood immunity above the Q100 where
alternative means to mechanical pumping
are used to achieve such immunity; or
S12.5 Basements for non-residential uses
have flood immunity above the Q100 that
may be achieved by means of mechanical
pumping where the mechanical feature is
installed with adequate holding tanks and
an alternative back up power source.
Sloping sites S13.1 Buildings are of split level design that Not applicable.
O13 On sloping sites, buildings and structures step down the slope or have a suspended
are designed to maximise the use of natural floor construction; (See Figure 8.1 below) The proposed development is for a boundary realignment only.
slope and minimise the need for cut and fill. AND
S13.2 Cut or fill is less than 2m in depth;
AND
S13.3 The distance between the ground
and the lowest part of the floor of the