15. Copies of the approved plans (incorporating any modifications required due to conditions
contained herein) duly signed by the consultant Registered Professional Engineer of
Queensland (RPEQ) shall be provided to Council’s Construction Technical Officer at the “pre
start” meeting.
16. The filling of the site and construction of the proposed building and fencing shall not create
additional ponding of stormwater on any adjoining property.
17. Roof and surface runoff connection to Council’s kerb and channel shall be as shown on Spice
Consulting’s Drawing No. 686-01, A. Kerb adaptors shall be used in the kerb.
18. A 1.5 metre wide concrete footpath shall be constructed across the full frontage of the
development. The alignment shall be determined on site with Council’s Construction Technical
Officer. The footpath shall have a slip resistant surface. The expansion joints in any
bikeway/footpath shall be “saw cut”, not trowel jointed.
19. The vehicular access driveway serving the development shall be constructed with a maximum
width of 4.5m.
20. The driveway and any associated fencing or vegetation shall comply with the minimum sight
line requirements as defined in AS2890.1, sec 3.2.4.
21. Council’s Construction Technical Officer (ph 0410 512 505) shall be given seven (7) days’
notice of intention to commence works to arrange a “pre start” meeting prior to the
commencement of works.
22. The principal contractor must have all the appropriate insurance and public liability
documentation to carry out the works. The principal contractor is also responsible to ensure
that any sub contractors also have the appropriate insurance and public liability
documentation.
23. Prior to the “pre start” meeting, the principal contractor must be provided with a copy
of Council’s signed approved drawings and conditions by the applicant.
24. The Consulting Engineers for the project shall be currently Registered Professional Engineers
of Queensland (RPEQ). The consulting engineers are responsible for arranging all
inspections with Council’s Construction Technical Officer or nominated staff. Council’s
Construction Technical Officer shall provide an inspection form for signing off by the Engineer
at appropriate stages of construction, during on-site meetings. Construction Technical Officer
will also sign the form at each stage when requested conditions have been satisfied.
25. Prior to works commencing, Council is to be advised of the Engineer (RPEQ) supervising the
project. (This person will be the contact for the project).
26. Council standards shall apply to these works unless otherwise modified herein.
27. The person acting on this permit shall ensure that its consultants and contractors take all
reasonable care during the construction of the engineering works to ensure that Council
property, road pavements or facilities (such as underground drainage, water supply,
sewerage, footpaths, kerbing, landscaping, street furniture, etc.) are protected against any
damage or interference whatsoever.
If any Council property or facilities should be damaged by the Applicant or any of its
Consultants or Contractors through any cause whatsoever in the course of, directly or
indirectly, carrying out the engineering works, the Applicant and/or its Contractors shall
forthwith notify the Manager Land Development and shall forthwith rectify the damage to that
property or facility at its cost and to the satisfaction of the Manager Land Development.
All rectification works are to be completed prior to the commencement of the use or,
alternatively, the Applicant may request Council to carry out the rectification work at the
Applicant’s cost, such cost being paid by the Applicant to Council prior to the commencement
of the use.
3 of 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Negotiated Decision Notice - 010.2008.00000066.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 62 KB (small file)
- File type
No other editions are linked here.