56.   Prior to the commencement of any use or sealing of Plan of Survey, whichever occurs
      first, an acoustic screen must be constructed around the IGA rooftop mechanical plant
      to a height of 3.0 metres above the roof level plant deck, as shown on Figure 4 and
      described in Section 4.6 of the Second Joint Report of Experts in Noise (30 May 2018)
      for Planning and Environment Court Appeal 4066 of 2017.
57.   Prior to the commencement of use of the Visitor accommodation Type 4 dwelling units
      an acoustic barrier along the common boundary of the development site with the
      Peregian Beach Hotel must be constructed. The barrier shall be constructed of materials
      to achieve a minimum surface density 12.5 kg/m2 and a height 2.5 metres above the
      hotel pavement level along the boundary of the site and adjacent to the hotel drive-
      through lane and carparking areas, as shown on Figure 4 and described in Section 4.8
      of the Second Joint Report of Experts in Noise (30 May 2018) for Planning and
      Environment Court Appeal 4066 of 2017.
58.   Written certification is required from a suitably qualified person confirming that sound
      pressure levels from all mechanical plant and equipment within the development site
      comply with the following when measured at the façade of any habitable room or formal
      outdoor area of the Visitor accommodation Type 4 motel building or the Visitor
      accommodation Type 4 dwelling units. Noise levels to be measured as LAeq adj 15min
      where adjustments refer to tonality or impulsivity, in accordance with the most recent
      edition of the Queensland Noise Measurement Manual:
      (a)   Air-conditioning and Refrigeration
            (i)     7am to 10pm: Maximum level allowable = background + 5dB(A)
            (ii)    10pm to 7am: Maximum level allowable = background + 3dB(A)
      (b)   Pumps
            (i)     7am to 7pm: Maximum level allowable = background + 5dB(A)
            (ii)    7pm to 10pm: Maximum level allowable = background + 3dB(A)
            (iii)   10pm to 7am: No audible noise.
      The certification must be submitted to Council prior to commencement of the use, which
      certifies that operational noise from any fixed plant and equipment complies with the
      requirements of this Decision Notice.
59.   Written certification is required from a suitably qualified person confirming that sound
      pressure levels from all mechanical plant and equipment from the existing IGA shopping
      centre comply with the following when measured at the boundary of the newly created
      lot. Noise levels to be measured as LAeq adj 15min where adjustments refer to tonality
      or impulsivity, in accordance with the most recent edition of the Queensland Noise
      Measurement Manual:
      (a)   Air-conditioning and Refrigeration
            (i)     7am to 10pm: Maximum level allowable = background + 5dB(A)
            (ii)    10pm to 7am: Maximum level allowable = background + 3dB(A)
      (b)   Pumps
            (i)     7am to 7pm: Maximum level allowable = background + 5dB(A)
            (ii)    7pm to 10pm: Maximum level allowable = background + 3dB(A)
            (iii)   10pm to 7am: No audible noise.
      The certification must be submitted to Council, which certifies that operational noise from
      any fixed plant and equipment complies with the requirements of this Decision Notice.
      The certification must be provided prior to sealing of the plan of survey or
      commencement of use of the Visitor accommodation Type 4 motel building, whichever
      occurs first.




                                         Page 16 of 46

Used in these records

About this file

File size
5.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Final Judgment - Court Order Approval MCU16_0153 REC16_0041.pdf · 5.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.