5.3.2 Sources of Contaminants
Gross Pollutants
Gross pollutants include litter, grit and heavier sediments which can be mobilised from within or from
neighbouring sites.
Potential Causes
Unsecured refuse areas.
Un-landscaped areas prone to stormwater scour.
Insufficient drainage for surface runoff from within the site.
Wind Bourne transportation.
Mitigating Measures
Well established refuse areas with ample storage bins. Fenced off where deemed
necessary.
Provision of ample litter bins across the commercial footprints of the site. Particularly in
any outdoor dining or areas of congregation.
Promotion of stormwater surface runoff through landscaped areas or similar sediment
buffering strips/traps.
Provide stormwater pits outside paved areas that receive runoff from areas prone to gross
pollutants with surrounding buffering measures, such as stone pitching.
Provide gross pollutant inserts into stormwater pits within paved areas that receive runoff
from areas prone to gross pollutants.
Hydrocarbon Runoff:
Hydrocarbons can be mobilised and transported in stormwater runoff from the site. This can contaminate
stormwater runoff compromising Water Quality Objectives.
SCG Consulting Engineers Page 11 SCG Ref: 31131(SWMP).RevA
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SCG 31131(SWM).RevA.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.