Council archive · source document
Development Application Part 2 of 2 Report/ Plans - MCU12/0047
Plans and drawings: the text below has words only, no drawings.
Very large file (43.4 MB): may take a few minutes to open.
Original PDF page 28, section 1. The text section number identifies this passage in the reader.
Specific Outcomes Probable solutions Proposal
traffic areas No public toilets are proposed.
AND
029 Public toilets are designed and 529.2 Features that may legitimise Complies
constructed to- loitering, such as seating or public The proposed seating is not within 20m
a) ensure the safety of all people using telephones are not located within 20m of public toilet entrances.
them; and of toilet entrances;
b) take advantage of informal AND
surveillance from adjoining uses and
activities, discouraging non-legitimate 529.3 Entrances to public toilets are Not Applicable
uses. visible from the street, footpath and No public toilets are proposed.
other activity areas on the site or
adjoining sites.
030 Premises have accessibility to 530.1 Safe and convenient pathway Complies
pu blic tra nsport. access is provided from the site to link Safe and convenient pathway access is
to existing pathway networks that achieved from the site to existing
services public transport facilities; pathway networks adjoining the site.
OR
530.2 Direct pathway access is Complies
provided to the public transport facility if Pathway access around the site
the facility is contained on site or within frontages will be maintained.
SOm from the property boundary.
031 Business Uses are designed and 531.1 Safe and convenient cycle access Complies
constructed to encourage users of the to and from the site from the existing Safe and convenient cycle access is
development to access the site by road and bicycle network, and safe provided from the existing road and
means of footor bicycle through bicycle movement within the site is bicycle network.
provision of appropriate end-of trip provided;
facilities including bicycle parking and AND
shower/change rooms.
531.2 Secure and convenient parking Not Applicable
space for bicycles is provided on site in The proposed works result in a
accordance with AS2890.3 Bicycle reduction of existing commercial use on
Parking Facilities and Figure 14-1 the site. No new bicycle parking is
Minimum Requirements for Bicycle required.
Parking;
AND
531.3 Where at least S bicycle parking Not Applicable
spaces are required in accordance with No end of trip facilities are required.
Figure 14-1 Minimum Requirements for
Bicycle Parking, end-of-trip cycle
facilities are provided at the following
rate:
a) 1 locker per 2 bicycle parking
spaces; and
b) 1 shower cubicle with ancillary
change rooms per 10 bicycle spaces
or pa rt thereof;
AND
531.4 Bicycle parking spaces and cyclist Not Applicable
facilities are designed in accordance with No bike facilities are required.
AUSTROADS Guide to Traffic
Engineering Practice, Part 14 -
Bicycles,
Section 10;
AND
531.5 On-site pedestrian facilities such Complies
as seating and shade structures are A seat and awning is provided at the
provided in developments for the shop frontage.
convenience of persons walking to the
site.
5ite facilities
032 Waste storage areas, external 32.1 Waste storage areas, external Complies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 Report/ Plans - MCU12/0047Related documentApplication case desk ↗
About this file
- File size
- 43.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.