Original source · versioned page text
Appendix E - Noosaville Locality Code - MCU19-0030
Appendix E Noosaville Locality Code
Development Permit for Material Change of Use for Type 4 Conventional (3 units) at 217 -219 Gympie Terrace Noosaville
described as Lot 1 on RP66483 and Lot 1 on RP70165
Column 1 Column 2 Column 3
Specific Outcomes Probable Solutions (if code Compliance
assessable)
the overall built form. A range of building
materials are also used to provide visual
relief.
h) help protect the natural character and visual
amenity of the Noosa River system and other
watercourses.
- The reduced third level rear setback is not
visible from the Noosa River and does not
impact on the amenity of this area
Site cover, gross floor area and plot ratio
10 The site cover, gross floor area and plot ratio of No solution provided Applicants designer indicates that proposal
buildings and other roofed structures— complies with requirements
a) results in a building scale that is compatible with
surrounding development;
b) does not present an appearance of bulk to
adjacent properties, roads or other areas in the
vicinity of the site;
c) maximises the retention of existing vegetation
and allows for additional soft landscaping between
buildings;
d) allows for adequate area at ground level for
outdoor recreation, entertainment, clothes drying
and other site facilities; and
e) facilitates onsite stormwater management and
vehicular access.
O14 For the Visitor Mixed Use Zone, the Applicants designer indicates that proposal
maximum gross floor area equals the allowable complies with requirements
population in persons multiplied by 40m2 ,
provided that the gross floor area does not exceed
13,600m2
Flooding and drainage
O17 Buildings and other works are designed and S17.1 For new buildings or structures S17.1 Complies - habitable rooms are above
sited to— or additions of more than 50m2 gross prescribed minimum floor levels.
a) provide flood free access to premises and flood floor area to an existing building or
free habitable areas; structure, floor levels for habitable
b) allow only minor, short term and infrequent rooms are not less than the specified
flooding of non-habitable areas; minimum floor levels;
c) ensure carparking areas can be adequately AND
drained; S17.2 Where Council infrastructure is S17.2 Applicant will comply with relevant
d) ensure drainage does not adversely impact available— requirements.
upon other premises; and a) any drainage (including buildings
e) ensure filling or excavation does not adversely and yards) flows to that infrastructure;
impact upon other premises by— and
i. causing ponding on the site or nearby land; b) the infrastructure has the capacity
ii. increasing flooding, which adversely affects the to accept any additional loading;
safety or use of any land upstream and AND
downstream; and S17.3 For Residential Uses— S17.3 Proposal generally complies with the
iii. adversely affecting the flow of water in any a) where slab on ground construction probable solution with filling generally located
overland flow path. is used, filling does not extend more around building footprint.
than 1m beyond the building footprint
and access to car parking areas,
measured from the outer walls of the .
building ; or
b) the design consists of a suspended
floor
construction;
AND
S17.4 Car parking and maneuvering 17.4 Complies – refer appendix C
areas are constructed at a level that
permits the parking area to drain from
the site by gravity means, without the
need for mechanical pumping;
AND
Page 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.