Planning Scheme Policy
commenced 3 Febniary 2006

1.15

4.16

Figure 5

1.19
1.20

1.21

1.22

1.23

1.24

Water reticulation systems shall be fitted with a mechanical backflow prevention device.

Any electrical reticulation system carrying electricity in excess of 24 volts is not to extend
beyond the revetment wall.

Boat ramps (see Figure 5)

   
 

150mm. max above

if
fp of ws y 200 mm, max. above
~. clavel of beach.
— Z

The levels of a boat ramp surface at the revetment wall shall be not more than 150mm
above the top of the wall, not more than 500mm below the top of the wal! and not more than
200mm above the existing beach.

The ramp shall not extend into a canal more than 9m from the revetment wall.
The ramp shall be constructed at a uniform grade and shall be no steeper than 1 in 5 (20%).
The outer end of the ramp shall be no more than 100mm above the level of the beach.

No part of the ramp is to extend closer than 1m to the prolongation of the side boundaries of
the property.

Shelter Structures for North Shore Jetties

Council may agree to light roofed timber shelter structures associated with jetties on the
North Shore. The purpose of the structure is to cover boats in circumstances where all
weather motor vehicle access is not available to the site. This section of the policy does not
apply to sites that may be readily accessed by motor vehicles.

A cantilevered structure off the jetty is preferred but Council may agree to separate
foundations in the waterway. (Approval is more likely for a cantilevered structure as it is
unlikely to involve foundations in the Fish Habitat Reserve Area).

Any shelter structure must comply with the following—

a) There must be a general head clearance of 2.4m between the jetty surface and the
underside of the roof structure;

b) The roof structure must not exceed 3m in height above the jetty surface level;

c) The roofed area must not exceed dimensions of 6m by 3m. The length of the structure
is to be generally perpendicular to the riverbank. Lattice is permitted to be attached to
the structure but not a solid wall;

4
PSP04 Domestic Marine Uses outside Noosa Waters Estate

Used in these records

About this file

File size
3.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_1704 - Operational Works - Prescribed Tidal Works - Transport Type 5 - Domestic Marine (Not Properly Made) [As Published].pdf · 3.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.