SUPERSEDED Reference Document Bushfire Hazard Assessment & Management Plan v 2 June 2024 MCU24 0084 (1)
Bushfire Hazard Assessment & Management Plan v2 NCES REF: J001313 Lot 4 on RP160124 — 658 Louis Bazzo Dr, Ringtail Creek QLD 4565 5 BUSHFIRE MANAGEMENT MEASURES 5.1 General The following section describes bushfire management measures to be incorporated into the proposed development to reduce the risk of bushfire impacts to people and property. Implementation of the identified measures is not implied nor intended to advocate that building occupants remain on the site during a bushfire event, nor that people and property will be protected from bushfire impacts. The measures are intended to reduce the potential severity of bushfire impact to the development and not prevent bushfire impact. The bushfire mitigation measures have been derived from: e Department of State Development, Manufacturing, Infrastructure and Planning’s State Planning Policy — State interest guidance material — Natural hazards, risk and resilience — Bushfire (December 2019) (referenced herein as SPP (Bushfire) 2019); and e¢ Queensland Fire and Emergency Services. (2019). Planning for Bushfire Resilient Communities. 5.2 Asset Protection Zones Asset Protection Zones (APZ) provide a defensive tool to assist in the reduction of potential bushfire impact to people and property situated in bushfire prone areas. For illustrative purposes, Plate 7 depicts the concept of an APZ surrounding a dwelling in a bushfire prone area. Building envelope Inner Protection Area Outer Protection Area Bushland horizontal considerations APZ Plate 7 — Asset Protection Zones The proposed development footprint (wedding marquee and access) has been confirmed to be located within a bushfire hazard area. The risk assessment undertaken in Section 4 identifies the proposed plan of development satisfies the minimum separation distances required to achieve <29kW/m? radiant heat flux exposure to the wedding marquee. Therefore, no changes to the arrangement or position the building is required. It is noted the marquee is expected to be constructed of a canvass like material which offers limited to negligible resistance against direct flame, radiant heat and ember attack. The modelled radiant heat flux exposure acting on the marquee was determined to be 8.02 kW/m * and therefore patrons would be expected to be exposed to pain within 10 — 20 seconds of direct exposure (i.e., outside of the marquee) to a fire front positioned on the edge of SU9b to the north. The minimum <29kW/m? radiant heat flux exposure separation distance between the wedding marquee and the adjacent hazardous vegetation; Sub unit 9b, is to comprise an Asset Protection Zone. Maintenance of landscaping conditions within the APZ is recommended to satisfy Assessment Benchmark 5 of the SPP Bushfire 2019 and the low threat vegetation criteria prescribed in @ © 2020 23 Document Set ID: 23422887 Version: 3, Version Date: 14/01/2025
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewSearchable page text hides email addresses. Original files are unchanged and may show email addresses.