Bushfire Hazard Assessment & Management Plan v2 NCES REF: J001313 Lot 4 on RP160124 — 658 Louis Bazzo Dr, Ringtail Creek QLD 4565 section 2.2.3.2 of AS 3959:2018 or later iterations thereof. A further detailed description of APZ landscaping requirements is detailed in Section 5.6 Landscaping and Regrowth. 5.3 Water Supply The availability of a reliable water supply for firefighting purposes is a vital tool in the defence of bushfire impact. Reticulated water supply is currently not available within the site nor proposed to be connected to the site. The proposed wedding marquee will therefore require provision of a readily accessible on-site emergency static water supply in accordance with Assessment Benchmark 4 of the SPP Bushfire 2019, which references the QFES 2019 Bushfire Resilient Communities document for information regarding appropriate static water supply. Section 9.1 of Bushfire Resilient Communities’ states: An appropriate static water supply (in bushfire prone areas where reticulated supply is not provided) to support effective emergency services response includes a water tank that is available solely for firefighting purposes and can be accessed by firefighting appliances. The water tank is to be provided within 10 metres of each building (other than a class 10 building), which: a) is either below ground level or of non-flammable construction; b) has a take-off connection at a level that allows the following dedicated, static water supply to be left available for access by firefighters: i.10,000 litres for residential buildings; It is therefore recommended that a dedicated 10,000 litres for firefighting purposes is made available to the proposed wedding marquee. Plate 8 outlines an example of a reserve water supply in a standard tank. Domestic Water Domestic water outlet Fire fighting outlet Plate 8 - Example Static Water Supply tank design for firefighting purposes (Source: Kingspan Group 2021) In addition, it is recommended that the water supply is installed in accordance with: 1. Fire Hydrant and Vehicle Access Guidelines for residential, commercial and industrial lots, Queensland Fire and Emergency Services, 2015, unless otherwise specified by the relevant water entity; and 2. The Road Planning and Design Manual 2nd edition, Department of Transport and Main Roads, 2013. Note: when relevant, the superseding versions will apply. @ see © 2024 24 neem Sanayont Document Set ID: 23422887 Version: 3, Version Date: 14/01/2025
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewSearchable page text hides email addresses. Original files are unchanged and may show email addresses.