Att6 - Noise Impact Assessment

of 25

Page text shows just the words. Original shows the document exactly as it was published.

Christian Youth Council
Environmental Noise Level Impact Assessment for Proposed Extensions to CYC Youth Camp,
48 Kabi Road, Cootharaba                                                                              Page 13 of 22




R4 – Closest Residence to West

At the closest residence to the west on the southern side of Kabi Road the above noise sources will
be:

    •    vehicles (10 to 15 kph speed):
             o passenger:
                     ▪ driving:               40 – 33 (350m distance) – 7 (ground) = 0 dB(A) LAeq,adj,T;
                     ▪ door close:            50 – 36 (500m distance) – 8 (ground) = 6 dB(A) LAeq,adj,T;
                     ▪ engine start:          50 – 36 – 8 = 6 dB(A) LAeq,adj,T;
              o   bus idling, driving off and arriving at parking bay, including air brakes:
                                             65 – 37 (560m distance) – 8 (ground) = 20 dB(A) LAeq,adj,T;
              o MRV truck driving and unloading, including air brakes:
                                             67 – 37 (560m distance) – 8 (ground) = 22 dB(A) LAeq,adj,T;
              o waste collection vehicle driving, emptying waste receptacles and departing:
                                             68 – 37 (560m distance) – 8 (ground) = 23 dB(A) LAeq,adj,T;
    •    children/youth playing:
              o 10 children/youth:           61 – 38 (600m distance) – 8 (ground) = 15 dB(A) LAeq,adj,T;
              o 50 children/youth:           68 – 38 – 8 = 22 dB(A) LAeq,adj,T;
              o 100 children/youth:          71 – 38 – 8 = 25 dB(A) LAeq,adj,T;
    •    basketball match, including umpires whistle and yelling and screaming and cheering:
                                             65 – 38 (600m distance) – 8 (ground) = 19 dB(A) LAeq,adj,T;
    •    large air-conditioning unit:        54 + 5 (3 units for office and dining) – 37 (570m distance) – 8
                                             (ground) = 14 dB(A) LAeq,adj,T;
    •    kitchen exhaust fan:                50 – 38 (600m distance) – 8 (ground) = 4 dB(A) LAeq,adj,T;
    •    Village 1 air-conditioning:         54 + 7 (5 units, one per dormitory) – 39 (730m distance) – 9
                                             (ground) = 13 dB(A) LAeq,adj,T.

All of the above source noise levels, calculated to the closest residence to the north-west, individually
comply with the daytime, evening and night-time noise limits, with no additional noise control
measures in place.

For the daytime the relevant combined source noise levels would be 0 + 6 + 6 + 20 + 23 + 25 + 19 +
14 + 4 + 13 = 29 dB(A) LAeq,adj,T, which is worst case and complies with the daytime noise limit.

For the evening the relevant combined source noise levels would be 0 + 6 + 6 + 20 + 19 + 14 + 4 + 13
= 24 dB(A) LAeq,adj,T, which is worst case and complies with the evening noise limit.

It is not anticipated that there would be any night-time noise sources other than air-conditioning, which
the combined effect of Village 1 complies with the night-time steady state noise limit of 23 dB(A) LA90,T.




David Moore & Associates Pty Ltd                                  Our reference: R22072.docx/D3681/Rev.0/25.08.2022
Log in to download the original file

Att6 - Noise Impact Assessment.pdf · 2.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.