Att6 - Noise Impact Assessment
Christian Youth Council
Environmental Noise Level Impact Assessment for Proposed Extensions to CYC Youth Camp,
48 Kabi Road, Cootharaba Page 14 of 22
R5 – Closest Residence to West
At the closest residence to the west on the northern side of Kabi Road the above noise sources will
be:
• vehicles (10 to 15 kph speed):
o passenger:
▪ driving: 40 – 33 (350m distance) – 7 (ground) = 0 dB(A) LAeq,adj,T;
▪ door close: 50 – 36 (500m distance) – 8 (ground) = 6 dB(A) LAeq,adj,T;
▪ engine start: 50 – 36 – 8 = 6 dB(A) LAeq,adj,T;
o bus idling, driving off and arriving at parking bay, including air brakes:
65 – 36 (530m distance) – 8 (ground) = 21 dB(A) LAeq,adj,T;
o MRV truck driving and unloading, including air brakes:
67 – 36 (530m distance) – 8 (ground) = 23 dB(A) LAeq,adj,T;
o waste collection vehicle driving, emptying waste receptacles and departing:
68 – 36 (530m distance) – 8 (ground) = 24 dB(A) LAeq,adj,T;
• children/youth playing:
o 10 children/youth: 61 – 37 (570m distance) – 8 (ground) = 16 dB(A) LAeq,adj,T;
o 50 children/youth: 68 – 37 – 8 = 23 dB(A) LAeq,adj,T;
o 100 children/youth: 71 – 37 – 8 = 26 dB(A) LAeq,adj,T;
• basketball match, including umpires whistle and yelling and screaming and cheering:
65 – 37 (570m distance) – 8 (ground) = 20 dB(A) LAeq,adj,T;
• large air-conditioning unit: 54 + 5 (3 units for office and dining) – 37 (550m distance) – 8
(ground) = 14 dB(A) LAeq,adj,T;
• kitchen exhaust fan: 50 – 37 (550m distance) – 8 (ground) = 5 dB(A) LAeq,adj,T;
• Village 1 air-conditioning: 54 + 7 (5 units, one per dormitory) – 39 (700m distance) – 9
(ground) = 13 dB(A) LAeq,adj,T.
All of the above source noise levels, calculated to the closest residence to the north-west, individually
comply with the daytime, evening and night-time noise limits, with no additional noise control
measures in place.
For the daytime the relevant combined source noise levels would be 0 + 6 + 6 + 21 + 24 + 26 + 20 +
14 + 5 + 13 = 30 dB(A) LAeq,adj,T, which is worst case and complies with the daytime noise limit.
For the evening the relevant combined source noise levels would be 0 + 6 + 6 + 21 + 20 + 14 + 5 + 13
= 25 dB(A) LAeq,adj,T, which is worst case and complies with the evening noise limit.
It is not anticipated that there would be any night-time noise sources other than air-conditioning, which
the combined effect of Village 1 complies with the night-time steady state noise limit of 23 dB(A) LA90,T.
NOISE CONTROL
To ensure compliance with the noise limits for the complete 24-hour day at all of the closest
residences to following restrictions need to be implemented:
1. bus access to the site to be limited to daytime and evening only – 0700 to 2200 hours;
2. delivery vehicles must only access the site during the daytime – 0700 to 1800 hours;
3. waste collection vehicles must only access the site during the daytime – 0700 to 1800 hours.
Compliance with the above will result in compliance with the noise limits for the complete 24-hour day.
David Moore & Associates Pty Ltd Our reference: R22072.docx/D3681/Rev.0/25.08.2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.