190629 AGLA Essence David Low Way (215), Peregian Beach issue C
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
PROPOSED ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
Landscape Design Development Package
QLD 4122
T 07 3420 0006
M 0405 389 243
E [email protected]
Prepared GENERAL NOTES:
1. Read all landscape drawings and specifications and clarify
any discrepancies with the Project Manager prior to
By For
undertaking works.
2. All work practices shall comply with the Occupational
Health and Safety Act 2004 and all relevant regulations and
codes of practice.
3. The location of the site compound and area for stockpiling
of materials is to be agreed on site and authorized by the
Project Manager prior to the commencement of works.
4. The site is to be secured for the full duration of works at the
Contractor’s expense.
5. The Contractors must check all dimensions and levels on
site. The proposed works must match into existing site
levels where they interface with existing conditions.
6. The Contractor is to locate and confirm all existing services
and service covers, whether shown on the drawing or not,
prior to the commencement of works. The Contractor shall
contact Dial Before You Dig to obtain any relevant service
information prior to the commencement of works.
7. The Contractor is responsible for retaining, protecting and
repairing any damage to all existing services, service
covers etc. The Contractor shall advise the Project
Manager of any required alternations.
8. Confirm all pit levels and resolve any discrepancies with the
Project Manager prior to undertaking the works.
9. All levels are to be approved on site by the Project Manager
at setout prior to undertaking the works.
10. All surface levels nominated on the plans are finished
surface levels. The Contractor must include excavation,
SITE LOCATION PLAN SCHEDULES
trimming and grading to appropriate sub-grade levels to
achieve specified depth and adequate drainage of softfall
mulch.
DRAWING SCHEDULE 11. Sub-grade in softfall mulch zones to have minimum of 1:50
fall towards agricultural drains. Typically provide falls
DWG NO DRAWING TITLE ISSUE across hard surfaces towards gardens beds.
Minimum fall in direction of travel – 1:90
0 COVER SHEET C
David Low Way
Maximum fall in direction of travel – 1:20
1 LANDSCAPE WORKS NOTES C Maximum crossfall – 1:40
2 PLANTING SCHEDULE AND IMAGES C
3 OVERALL LANDSCAPE PLAN C
4 PROPOSED FENCES PLAN C
5 EXISTING TREES PLAN C
6 SURFACE FINISHES PLAN 1 C
7 SURFACE FINISHES PLAN 2 C
8 SURFACE FINISHES PLAN 3 C
9 SURFACE FINISHES PLAN 4 C
10 SURFACE FINISHES PLAN 5 C
11 PLANTING PLAN 1 C
12 PLANTING PLAN 2 C
13 PLANTING PLAN 3 C
14 PLANTING PLAN 4 C
15 PLANTING PLAN 5 C
16 DETAILS C
17 DETAILS C
C 28/06/19 FOR TENDER
B 28/06/19 FOR REVIEW
A 26/06/19 FOR REVIEW AND COORDINATION
ISSUE DATE REASON
DRAWING REFERENCE SCHEDULE THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
CONSULTANT TYPE DRAWING FILE NAME DATE RECEIVED RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
MORGAN CONSULTING ENGINEERS CIVIL DRAWING 19-06-25 - 18164 - MCE CIVIL BASE.DWG 25/06/19
RED DOOR ARCHITECTURE ARCHITECTURAL DRAWING 180082-WD-A-100-4 - SITE PLAN - GROUND FLOOR DETAIL.DWG 25/06/19
180082-WD-C-100-1 - FLOOR PLANS (KAMALA).DWG 03/06/19
180082-WD-D-100-1 - FLOOR PLANS (LILY).DWG
180082-WD-E-100-1 - FLOOR PLANS (MARRAM).DWG
N 180082-WD-F-100-1 - FLOOR PLANS (SALTBUSH 1).DWG
180082-WD-G-100-1 - FLOOR PLANS (SALTBUSH 2).DWG
180082-WD-H-100-1 - FLOOR PLANS (WALLUM).DWG ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH
COVER SHEET
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 0 C AL/CP AG/NC
NOT FOR CONSTRUCTION
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.
Full text of sections 2 to 5 (of 21)
Section 2
GENERAL NOTES
STRUCTURE AND BENCH SEATING
A. ARCHITECTURAL WORKS INFORMATION ORGANIC MULCHING - BULK PLANTING AREAS
Refer to Architect's drawings for all information contained within these documents related to and nominated as GENERALLY: Design and construct shelter structure with incporated seat in the location as shown on the
Architectural Works. This includes all hardscape items such as paving, outdoor structures / shelters, walls and GENERALLY: Proposed mulch must comply with Australian Standards AS4454-2003. drawings. The images and landscape drawings show the extent and design intent and the final finish should be
coherent with similar elements on site or as discussed with the landscape architect.
fencing. Architectural Works information contained within these documents are indicative only and not for ANDREW GOLD LANDSCAPE ARCHITECTURE
construction or certification purposes. MATERIAL: Spread 1" Hoop Bark to a minimum depth of 100mm entirely over planting bed areas as indicated
on the drawings. The construction methodology, timber sizes, finishing, fixings, wind loading, footings and final design will be PO BOX 5220
B. CIVIL WORKS INFORMATION undertaken by an engineer/ builder to the landscape architects approval. MT GRAVATT EAST
SUPPLIER: Centenary Landscape Supplies Ph (07) 3373 4999 or equal approved. QLD 4122
Refer to Civil Engineer's drawings for all information contained within these documents related to and
nominated as Civil Works. Civil Works information contained within these documents are indicative only and T 07 3420 0006
not for construction or certification purposes. INORGANIC MULCHING - AS INDICATED TIMBER GARDEN EDGE M 0405 389 243
E [email protected]
C. STRUCTURAL WORKS INFORMATION GENERALLY: Install inorganic mulch to a minimum of 75mm entirely over planting areas as indicated on the GENERALLY: Install to the locations as indicated on the drawings.
Refer to Structural Engineer's drawings for all information contained within these documents related to and drawings. Weed mat to be installed in all areas of inorganic mulch.
nominated as Structural Works. This includes retaining walls. Structural Works information contained within MATERIAL: Sawn hardwood of Durability Class 1 as defined in Appendix D of AS 1604 or CCA treated
these documents are indicative only and not for construction or certification purposes. MATERIAL: Inorganic mulch to be Tenterfield Pearl 20-40mm subject to sample. softwood.
SIZE: 3000 x 100 x 15mm nominal edgings, 50mm square pegs, 350mm long.
ORGANIC MULCH - 1 INCH HOOP BARK INORGANIC MULCH - 'TENTERFIELD PEARL' DECORATIVE BOULDERS
D. ELECTRICAL WORKS INFORMATION SUPPLIER: Centenary Landscape Supplies Ph (07) 3373 4999 or equal approved. INSTALLATION: Set edgings flush with adjoining surfaces to define planting, grass areas, pathway edges, etc.
Refer to Electrical Engineer's drawings for all information contained within these documents related to and Fix to pegs with galvanized nails, two per fixing. Drive pegs into the ground at 1200-1750mm centres on the
nominated as Electrical Works. Electrical Works information contained within these documents are indicative SANDSTONE STEPPERS turf side of the edging and on both sides of joints between boards with peg tops 15mm below top of edging.
and not for construction or certification purposes. CURVING: Where the timber edge is to be curved, space the pegs to hold it to a uniform curve.
GENERALLY: Use natural stone, which is uniform quality in each grade, sound and free from defects liable to
E. HYDRAULIC WORKS INFORMATION affect its strength. BIO-RETENTION BASIN
Refer to Hydraulic Engineer's drawings for all information contained within these documents related to and
nominated as Hydraulic Works. Hydraulic Works information contained within these documents are indicative SIZE: Random steppers to average approx. 400mm but varying in size/ shape for visual interest with gap of Refer to Engineering drawings for bio-retention details. Prior to planting, ensure installation of erosion control
only and not for construction or certification purposes. approx. 150 – 200mm between to allow for planting. matting (ie: Jutmaster Fine by Geofabric Australasia), secured as per manufacturer's recommendations.
SIZE: Regular steppers to be 300 x 1500mm min 20mm thickness or equal approved IRRIGATION
LANDSCAPE SPECIFICATION NOTES
SUPPLIER: Sandstone World Ph 0431 285 425 or equal approved. Planting plan has been designed to survive without an automatic irrigation system. Water additives and water
LEVELS-GENERAL NOTES
retention elements, along with hardy water-wise plants will ensure an irrigation system is not imperative to the
Finish organic mulch surfaces 25 - 40mm below adjacent paving surfaces and / or edging. Finish lawn surfaces
LAYING: Subgrade to be fully compacted before mortar bed is laid. Subgrade shall be compacted 95% of long-term maturation and survival of the proposed plants. If approved, install an automatic, fixed position, low
flush with adjacent paving surfaces and / or edging. Ensure adequate falls in finished surface levels away from
medium dry density. Mortar to comply with AS 3700 and match sandstone colour as new. Stone should vary in pressure sprinkler irrigation system to all landscaped areas shown on the drawings internal to the site only, to
buildings to drainage collection points (eg, field inlets, etc).
size and shape for interest and naturalistic look. Noosa Shire Council approval. The irrigation shall meet the following performance requirements and as per the
manufacturers and/or installers specifications:
SUBSOIL DRAINAGE - GENERAL NOTES
CONCRETE AND PAVING • Summer target application of 32mm
Ensure adequate subsoil drainage elsewhere by installing suitable agricultural drainage systems where
• Fully automatic and metered
necessary, and especially in areas subjected to site excavation works including retaining walls.
GENERALLY: Install exposed aggregate and coloured concrete footpaths, driveways and roadways in the • Recycled water use (from rainwater tanks)
locations and to the extents as shown on the drawings. Refer drawings for the locations and extents of the • Commercial quality fittings and fixtures
PLANTS below types. • Mainlines
• Dripline system under mulch SANDSTONE REGULAR STEPPERS SANDSTONE RANDOM STEPPERS
• NATSPEC shall apply to trees where Council requires this certification. Type 1 Driveway: Boral exposed aggregate to match ‘Black night’ mix or equal approved based on supplied • RPZ backflow prevent device
• Plants are to be good quality nursery stock from a NIASA Accredited nursery sample. Level of exposure to be determined following sample.
• They shall be fundamentally free of pest and diseases. All design and documentation, materials supplied and work carried out should be in accordance with the
• After installation they shall be thoroughly watered. Type 2 Entry: Portland grey standard concrete trowel finish. Approval based on supplied sample. Not float current relevant Australian Standards and best practice.
edges. Trowel finish to be even across whole pour section.
TURF PLANT ESTABLISHMENT / CONTINUING MAINTENANCE
Type 3 Footpath: CCS Full depth coloured concrete sand colour or equal approved based on supplied sample.
SUBGRADE PREPARATION: Allow a 12 WEEK Plant Establishment Period from Practical Completion to the satisfaction of the Landscape
Turfed areas shall be prepared initially by removing all deleterious material Type 4 Footpath: Portland grey standard concrete trowel finish. Approval based on supplied sample. Not float Architect.
Cultivate subgrade surface by thoroughly ripping to a minimum depth of 150mm before spreading topsoil edges. Trowel finish to be even across whole pour section. • Maintain adequate watering regime
unless otherwise directed (ie: no cultivation under trees to be retained) • Remove weed growth from all mass planting beds and turfed areas
Type 5 Roadway: CCS Full depth coloured concrete ‘Black 44’ or equal approved based on supplied sample. • Fertilise (as per the notes above)
SOIL: Depth and construction detail of roadway to engineer’s detail. • Weed control (as per the notes above)
Spread turf underlay topsoil to a minimum depth of 100mm unless otherwise directed. Proposed topsoil must • Prune planting, control pest and disease management (as per the notes above) to maintain healthy growth
comply with Australian Standards AS4419-2003 and described as 'Soil blend'. Type 6: Open jointed pavers located within the lots to be 400 x 400 x 40mm paver to match Boral Exposed • Replenish mulch material where necessary
aggregate ‘Coral Coast’ or equal approved based on supplied sample . • Replace dead / dying plant material
TURF: • Reinstate stakes, ties and marker stakes where necessary
To be fundamentally free from weeds and disease or other deleterious substances. Supplier: Exposed aggregate mixes to be Boral Ph 1300 305 980 and coloured concrete pigment to be CCS • Reinstate erosion control matting and other erosion control measures as necessary
• Turf to be Sir Grange (Zeon Zoysia) for all areas within the project designated as 'turf' (Concrete colour systems) Ph 1800 077 744
Continue maintenance works beyond Plant Establishment Period as required.
Supplier: Refer Lawn Solutions website for local growers https://lawnsolutionsaustralia.com.au/turf-suppliers/ or Joints: Construct joints in the patterning as shown on the drawings. Approximate locations of joints shown.
call 1300 883 711. Adjust accordingly to suit engineer’s requirement of frequency and types. MANAGEMENT PLAN/S:
INSTALLATION: DECORATIVE BOULDERS The turfed areas shall be throughly watered on the day of turf installation and then as follows at the equivalent CONCRETE PAVING TYPE 1 DRIVEWAY CONCRETE PAVING TYPE 3 FOOTPATH
Turf shall be close turfed with staggered cross-joints and laid in straight lines, running perpendicular to the of 5l/m², including natural rainfall, or as required to maintain active healthy growth.
direction of slope (and / or parallel to contours). GENERALLY: Place and secure decorative boulders in the locations as indicated on the drawings. Boulders to
Proposed topdressing soil to comply with Australian Standards AS4419-2003 and as described as be placed in a naturalistic and artistic arrangement. Weeks 1-3: Twice a week
'Topdressing'. Weeks 3-12: Once a week or as necessary
All joints shall be filled with an approved topdress light soil or sand and the turf shall be lightly rolled. MATERIALS: Boulders to range in size and vary between 400 x 400, 600 x 600 and 900 x 900 depending on
Finished levels shall be 3mm below surrounding surface levels to allow for future top dressing. Allowance the locations and availability. Source boulders to match with sandstone and gravel materials. If no irrigation, apply the above rates to the mass planting beds. Watering to use rainwater tanks if possible.
should be made for shrinkage and settling.
Turf shall be adequately watered once installed, refer Management Plan/s. GRAVEL TO FOOTPATH SPECIAL NOTE
Ensure protection from trampling.
GENERALLY: Install feature gravel to a minimum of 75mm in the locations as indicated on the drawings. Accord particular diligence to the following prime items:
FERTILISER:
Fertiliser to be applied to the turf at the rates and period of time from installation as recommended by the MATERIAL: Gravel to be Tenterfield Pearl 20-40mm subject to sample. TOPSOIL QUALITY and SUBGRADE PREPARATION as specified.
supplier. If no starter Fertiliser supplied by the supplier, we recommend:
Dynamic Lifter Turf Starter: SUPPLIER: Centenary Landscape Supplies Ph (07) 3373 4999 or equal approved. PLANT QUANTITY: Use only consistently well nurtured nursery stock from an approved supplier. Check with
http://www.yates.com.au/products/fertilising/organic-based/dynamic-lifter-turf-starter/ Landscape Architect where species substitutions must be made.
#tbCQXOZuFJZ01z1B.97 LIGHT BOLLARDS
Lawn Builder™ Seed & Turf Starter Slow Release Lawn Fertiliser: MAINTENANCE: Ensure a continuing maintenance program, including weed/disease, fertilising, watering (but
https://www.scottsaustralia.com.au/scotts-brands/lawn-builder/lawn-builder-slow-release- GENERALLY: Bollard lights to be installed under the electrical contract. If they are installed prior to landscape beware of over-watering) and replacement of ailing plant material.
lawn-fertilisers/lawn-builder-seed-turf-starter-slow-release-lawn-fertiliser/ works, ensure they are protected and maintained during works or rectified with like for like if damaged during
works. GUARANTEE
SOIL WETTING AGENT: Failure to adequately address these items, best practice and relevant Australian Standards WILL result in a
We recommend the application of a soil wetting agent wetting agent (ie: non biodegradable detergent not Refer engineer’s drawings for specification and locations as required. sub-standard landscape outcome. CONCRETE PAVING TYPE 2 ENTRY CONCRETE PAVING TYPE 5 ROADWAY CONCRETE PAVING TYPE 6
crystals) to stop hydrophobia if not already in the starter fertiliser supplied with the turf, at the rates
recommended by the manufacturer:
AND TYPE 4 FOOTPATH
FENCING
• Scotts Hydraflow Wetta Soil
• Searle’s Penetraide GENERALLY: Install fencing, screens, gates and associated locks and fixings in the locations as shown on the
• Plant of Health Soils Soaker drawings. The construction, finishing, fixings, wind loading, footings and final design will be undertaken by an
engineer/ builder. The images and landscape drawings show the extent and design intent and the final finish
WEEDS, PESTS DISEASE MANAGEMENT should be coherent with similar elements on site or as discussed with the landscape architect.
Weeds are required to be removed by physical or chemical (Glyphosate or other herbicides) means. If chemical
means, as per the manufacturer recommendations. Refer to the following reference for guideline on weeds, FENCE TYPE A1: 1500mm or 1800mm high fence (in outdoor shower locations) with 50 x 50mm timber
pest and disease management battens (or composite wood as approved) spaced at 50mm or 100mm spacings as indicated on the drawings.
REFERENCE: Colour finish to match house colour that it is located next to. Confirm with Architect on site.
http://thelawnguide.com.au C 28/06/19 FOR TENDER
B 28/06/19 FOR REVIEW
FENCE TYPE A2: 1500mm fence with 50 x 50mm battens at 50mm spacings fixed atop retaining wall. Colour
PLANTING BEDS A 26/06/19 FOR REVIEW AND COORDINATION
finish to match house colour that it is located next to. Confirm with Architect on site.
SUBGRADE PREPARATION: FENCE TYPE B Pool Fence: By others, refer Architects Drawings ISSUE DATE REASON
Cultivate subgrade surface by thoroughly ripping to a minimum depth of 150mm before spreading topsoil.
FENCE TYPE C Proposed Fire Protection Fence: By others, refer Architects Drawings THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE AT
TOPSOIL: THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
Spread topsoil to a minimum depth of 300mm unless otherwise directed. Proposed topsoil must comply with FENCE TYPE D1 Boundary: 1800mm high fence with 100 x 100mm posts and 100 x 10mm timber capping and INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
Australian Standards AS4419-2003 and described as 'Soil blend'. plinth. 100 x 20mm battens to be angled to obscure views through. RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
Provide certification of soil types delivered to site, as per AS4419-2003. ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
FENCE TYPE D2 Boundary Fence Acoustic: By others, refer Architects Drawings
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
FERTILIZER:
DIMENSIONS ARE TO BE VERIFIED ON SITE.
A slow or controlled release fertiliser organic or inorganic to be incorporated generally into the imported (or FENCE TYPE E Bin Enclosure: 1500 - 1800mm high fence/ gate with 50 x 50mm battens at 50mm spacings. FENCE TYPE A1 FENCE TYPE D1 FENCE AND GATE TYPE E FENCE AND GATE TYPE E
excavated / site topsoil). We recommend the following: Height of fence/ gate to be 1800mm for front access and 1500mm high for bin enclosures.
Inorganic Slow or Controlled Release fertilisers:
• Osmocote ENTRY FEATURE
• Nutricote
• Macrocote GENERALLY: Construct a major and two minor signage/ features in the locations as shown on the drawings.
• E-Scape PRO by eCo-Enviroment See indicative images to show materials, design intent and general proportions.
Organic slow release: All required fixings, footings, and construction methodology to engineer's / builder's confirmation and
• Dynamic Lifter
• Organic Link by Plant of Health
Landscape Architect's approval. Final locations, extent and positioning to Landscape Architect's approval and
may require the construction of a plinth to ensure visibility and appropriate finished levels.
ESSENCE OF PEREGIAN BEACH
WETTING AGENT:
215 DAVID LOW WAY, PEREGIAN BEACH
MATERIALS: Stone cladding from Eco Outdoor 'Cracken Back' Ph1300 131413. Project logo, lettering font and
A wetting agent and / or soil ameliorant including a wetting agent is required to all mass planting beds: sizing to be confirmed by project marketing / branding consultant.
• Scotts Hydraflow Wetta Soil
• Searle’s Penetraide Plant of Health Soils Soaker
• Multipro by eCo-Enviroment
LANDSCAPE WORK NOTES
PLANTING:
As indicated on plan.
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 1 C CP/NB AG/NC
STRUCTURE AND BENCH SEATING SHELTER STRUCTURE
NOT FOR CONSTRUCTION
Section 3
PLANTING SCHEDULE
TREES
The spacing of plants shown on plan have been derived as a compromise between growth rate, anticipated size, and the ability to provide a good vegetative cover within a reasonable space of time. Quantities indicated have been based on the spacing of individual plants appropriate to the
available area for the particular species used; where this available area increases (or decreases) through the course of construction, quantities may also need to increase (or decrease) to maintain the plant spacings indicated on plan.
CODE SPECIES COMMON NAME SIZE** QUANTITY SPACING HEIGHT* WIDTH*
TREES ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
Ba Backhousia citriodora Lemon Scented Myrtle 100L 4 as shown 8 4 MT GRAVATT EAST
QLD 4122
Ce Casuarina equisetifolia Australian Pine Tree 45L 22 as shown 8 4
Ca Cupaniopsis anacardioides Tuckeroo 100L 17 as shown 15 8 T 07 3420 0006
M 0405 389 243
Ht Hibiscus tiliaceus Cottonwood 100L 3 as shown 8 6 E [email protected]
HR Hibiscus tiliaceus Rubra Red Cottonwood 100L 17 as shown 8 5
Hf Howea forsteriana Kentia Palm 100L 13 as shown 10 6
Pt Pandanus tectorius Screw Pine 200L 9 as shown 5 5
Tl Tristaniopsis laurina Luscious Water Gum 100L 51 as shown 10 5
Backhousia citriodora Casuarina equisetifolia Cupaniopsis anacardioides Hibiscus tiliaceus Hibiscus tiliaceus 'Rubra'
Lemon Scented Myrtle Australian Pine Tree Tuckeroo Cottonwood Red Cottonwood
SCREEN PLANTING
ACM hem Acmena hemilampra (Syzygium hemilampra) Broad Leaved Lillypilly 45L 3 2.5 8 3
MET tom Metrosideros thomasii Christmas Bush 300mm 31 2.5 4-6 5
SYZ BB Syzygium australe Baby Boomer Lillypilly 200mm 189 1.2 1.5 1.5
SHRUBS
ADE ser Adenanthos sericeus Woolly Bush 140mm 113 1.2 1-5 1 - 1.5
BAE vir Baeckea virgata Dwarf Twiggy Heath Myrtle Dwarf 200mm 126 0.4 0.3 0.5
BAN spi Banksia spinulosa Stumpy Gold Stumpy Gold 140mm 71 0.9 0.5 1 - 1.5
CAR gra Carissa grandiflora Desert Star Desert Star 200mm 288 0.7 1 1
CAS gla Casuarina glauca Green Wave Casuarina Green Wave 140mm 92 1 1-2 1-2
COR alb Correa alba Compact Form Compact White Correa 140mm 26 1.2 0.3 1-2
HEL pet Helichrysum petiolare Hi Ho Silver Licorice Plant 200mm 25 1.2 1 1.5
Howea forsteriana Pandanus tectorius Tristaniopsis laurina Luscious
KAL SS Kalanchoe bracteata Silver Spoons Silver Teaspoons 200mm 43 0.8 1.2 1
Kentia Palm Screw Pine Water Gum
LOM hys Lomandra hystrix Mat Rush 140mm 258 1 1.8 1.5
LOM lon Lomandra longifolia Mat Rush 140mm 7 0.8 1.2 1.2
WES AB Westringia Aussie Box Aussie Box 200mm 397 0.7 0.9 0.8
SCREENING SHRUBS SHRUBS GROUNDCOVERS
GROUNDCOVERS
BAN ser Banksia serrata Pygmy Possum Pygmy Possum 140mm 23 1.8 0.3 2.5 - 3
CAR gla Carpobrotus glaucescens Aussie Rambler Pigface 140mm 35 1.5 0.2 2
CAR ros Carpobrotus rossii White Hot Karkalla 140mm 78 0.9 0.2 - 0.4 0.5 - 1
CAS CI Casuarina glauca Cousin It Prostrate Casuarina 140mm 30 1 0.3 1.5
LOM ver Lomandra Verday Dwarf Lomandra 140mm 473 0.5 0.5 0.6
MYO par Myoporum parvifolium Creeping Boobialla 140mm 66 1.2 0.3 [email protected] ccs
MYO par Myoporum parvifolium Creeping Boobialla 140mm 68 1.0 0.3 1.5
SCA aem Scaevola aemula Aussie Crawl Fan Flower 140mm 57 0.8 0.4 - 0.5 0.5 - 1
SEN ser Senecio serpens Blue Chalksticks 200mm 42 0.5 0.25 0.6
VIO hed Viola hederacea Native Violet 140mm 97 1 0.15 2 Acmena hemilampra Metrosideros thomasii Adenanthos sericeus Baeckea virgata Dwarf Banksia serrata Pygmy Possum Carpobrotus glaucescens Aussie Rambler
WES BCC Westringia bulli Coastal Creeper Prostrate Native Rosemary 175mm 188 1.5 0.2 2 Broad Leaved Lillypilly Christmas Bush Woolly Bush Twiggy Heath Myrtle Dwarf Pygmy Possum Pigface
@ 1m ccs
WES BCC Westringia bulli Coastal Creeper Prostrate Native Rosemary 175mm 40 1.5 0.2 2
GRASSES
FIN nod Ficinia nodosa Knobby Club Rush 140mm 43 0.6 1 0.8
LOM LL Lomandra Little Lime Little Lime Mat Rush 140mm 606 0.4 0.5 0.5
FEATURE PLANT
ASP ant Asplenium antiquum Birds Nest Fern 200mm 41 as shown 0.9 1.5 Syzygium australe Baby Boomer Banksia spinulosa Stumpy Gold Carissa grandiflora Desert Star Carpobrotus rossii White Hot Casuarina glauca Cousin It
CRI ped Crinum pedunculatum Swamp Lily 200mm 11 1.5 2 2 Lillypilly Stumpy Gold Desert Star Karkalla Prostrate Casuarina
BIORETENTION PLANTING TYPE 1
Carex appressa Tall Sedge Tube 204 6 per m²
Ficinia nodosa Knobby Club Rush Tube 204 6 per m²
Juncus usitatus Common Rush Tube 204 6 per m² GRASSES
Lomandra longifolia Mat Rush Tube 204 6 per m²
Total: 816
BIORETENTION PLANTING TYPE 2
Casuarina glauca Green Wave Correa alba Compact Form Lomandra Verday Myoporum parvifolium
Casuarina Green Wave Compact White Correa Dwarf Lomandra Creeping Boobialla C 28/06/19 FOR TENDER
Ficinia nodosa Knobby Club Rush Tube 146 6 per m² B 28/06/19 FOR REVIEW
Juncus usitatus Common Rush Tube 146 6 per m² A 26/06/19 FOR REVIEW AND COORDINATION
Myoporum parvifolium Creeping Boobialla 140mm 146 6 per m²
Total: 438 ISSUE DATE REASON
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
Ficinia nodosa Lomandra Little Lime INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
Knobby Club Rush Little Lime Mat Rush INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
*HEIGHT AND WIDTH: MINIMUM STOCK SIZES ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
Heights and widths as shown are at full maturation, indicative only and dependent on The recommended minimum plant size relative to the container size is as follows. Should the stem calliper of DIMENSIONS ARE TO BE VERIFIED ON SITE.
environmental and microclimatic factors height of the tree relative to the container size be less than the figures shown, the tree should be rejected.
** PLANT CONTAINER SIZE: Root ball volume Height (above container) Calliper (at 300mm) Clean trunk height
Helichrysum petiolare Hi Ho Silver Kalanchoe bracteata Silver Spoons Scaevola aemula Aussie Crawl Senecio serpens
400L 400 Litre container stock min Min. height at time of planting: 3m 45 litre 1.9 - 2.3 metres 30mm - 35mm 1200mm FEATURE PLANT Licorice Plant Silver Teaspoons Fan Flower Blue Chalksticks
200L 200 Litre container stock min Min. height at time of planting: 3m 75 litre 2.2 - 2.4 metres 40mm - 45mm 1400mm
100L 100 Litre container stock min Min. height at time of planting: 2.5m 100 litre 2.4 metres 50mm 1500mm
45L 45 Litre container stock min Min. height at time of planting: 1.8m 200 litre 3.6 metres 60mm 1500mm
25L 25 Litre container stock min Min. height at time of planting: 1m 300 litre 4.2 metres 70mm 1500mm ESSENCE OF PEREGIAN BEACH
300mm 300mm dia minimum pot size 400 litre 5.5 metres 70mm 1500mm 215 DAVID LOW WAY, PEREGIAN BEACH
200mm 200mm dia minimum pot size Palm trees NA NA 5 metres clear
140mm 140mm dia minimum pot size trunk
Tube 50x50x125mm deep tubestock
PLANTING SCHEDULE & IMAGES
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
Asplenium antiquum
Birds Nest Fern
Crinum pedunculatum
Swamp Lily
Lomandra hystrix
Mat Rush
Westringia Aussie Box
Aussie Box
Viola hederacea
Native Violet
Westringia bulli Coastal Creeper
Prostrate Native Rosemary
19.021 2 C CP/NB AG/NC
NOT FOR CONSTRUCTION
Section 4
2m CONCRETE FOOTPATH
Refer Specification Notes
RUFOUS STREET
3 .0
3 .0
3.0
RUFOUS LANE 900 DIA 900 DIA
ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
TE
TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE QLD 4122
TE TE TE TE TE TE
TE
TE
900 DIA
T 07 3420 0006
TE
TE
POOL RECREATIONAL BUILDING AND SHELTER 11 WALLUM 14 WALLUM
M 0405 389 243
TE
10 KAMALA 13 WALLUM 16 WALLUM E [email protected]
Refer Architectural drawings
TE
TE
TE
TE
TE
TE
TE
12 MARRAM 15 MARRAM
TE
TE
TE
TE
TE
POOL LEGEND
TE
TE
TE
TE
9 LILY
TE
TE
TE
PROPERTY BOUNDARY
TE
TE
TE
As taken from Survey drawings
TE
TE
BIO-RETENTION BASIN
TE
TE
TE
TE
Refer Civil Engineering drawings RETAINING WALL
TE
TE
Refer Engineering drawings
TE
TE TE TE
MINOR ENTRY SIGNAGE / FEATURE PROPOSED CONTOURS
Refer images for indicative concept As taken from Civil Engineering drawings
6.0
5.5
5.0
4.5
6.5
EXISTING / PROPOSED SEWER
As taken from Survey / Engineering drawings
TE TE
PROPOSED RETAINING WALL
TE
EXISTING / PROPOSED STORMWATER
TE TE
As taken from Survey / Engineering drawings
TE
Refer Civil Engineering drawings
TE
4.5
PEREGIAN BEACH
TE
TE
TE
17 SALTBRUSH 1 HOTEL EXISTING TREES
TE
TE
8 LILY As taken from Survey plans
TE
TE
TE
TE
TE
TE
TE
6 MARRAM
6.5
EXISTING TREES - REMOVED
TE
TE
TE TE
As taken from Survey plans
TE
TE
7 KAMALA
TE
TE
5 KAMALA
TE
TE
TE
TE
TE
TE
TE TE TE TE TE TE TE
TE
SANDSTONE REGULAR STEPPERS
TE TE TE
Refer Specification Notes
TE
TE
POOL RECREATIONAL BUILDING 18 SALTBRUSH 2
TE
TE TE TE
TE TE
TE
Refer Architectural drawings
TE
TE
4 KAMALA SANDSTONE RANDOM STEPPERS
TE
TE
TE
PROPOSED HARDSTAND 1 KAMALA Refer Specification Notes
TE
TE
Refer Architectural drawings 2 MARRAM
TE TE TE
TE
3 MARRAM
8.0
TE
TE
6.5
TE
PROPOSED TIMBER GARDEN EDGE
TE
TE
Refer Specification Notes and Detail
TE
TE
PROPOSED POOL FEATURE STRUCTURE
TE
TE
Refer Architectural drawings POOL 19 SALTBRUSH 1
TE
BUILDING / ROOF OVER
TE
TE
Refer Architectural drawings
TE
TE
TE
TE TE TE
PROPOSED TURFED AREAS
Refer Specification Notes
6.0
TE
TE
PROPOSED MULCHED PLANTING AREAS
TE
STORMWATER DETENTION TANK
TE
20 SALTBRUSH 2 Refer Specification Notes
UNDER AND PLANTING / TURF OVER
TE
Refer Engineering drawings
5.5
5.0
TE TE
PROPOSED GRAVEL PLANTING AREAS
Refer Specification Notes
BIN WASHDOWN &
GARDEN EQUIPMENT STORE
TE
900 DIA
PROPOSED / EXISTING EASEMENT
Refer Achitectural drawings
900 DIA
EASEMENT
PROPOSED HOTEL
TE
PROPOSED BIO-RETENTION BASIN
COUNCIL
Refer Specification Notes and
TE
RESERVE
Proposed Planting Schedule
SEWER EASEMENT
Redirected sewer
EXISTING SPECIALTY SHOPS
EXISTING IGA
MINOR ENTRY SIGNAGE / FEATURE
2m CONCRETE FOOTPATH
TE
Refer images for indicative concept
Refer Civil Engineering drawings
TE
DAVID LOW WAY
TE
PROPOSED ACCESS GATE
Provide new access gate to match existing
NOTE:
EMERGENCY EGRESS ROAD For surface finishes, refer separate plans
For fences, gates and screens, refer separate plans
TE
TE
EASEMENT
MASONRY BLOCK SCREEN FENCE
To bin store, refer Architectural drawings C 28/06/19 FOR TENDER
TE
B 28/06/19 FOR REVIEW
A 26/06/19 FOR REVIEW AND COORDINATION
TE
ISSUE DATE REASON
ENERGEX PMT SITE LOCATION
TE
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
Refer Architectural drawings AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
PROPOSED RETAINING WALL PEREGIAN VILLAGE MARKETS
TE
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
Refer Civil Engineering drawings RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
TE
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
TE
GRAPHIC SCALE (m) 1:300 @ A1
0 1 5 10 15
BUSHFIRE SETBACK ZONE
ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH
OVERALL LANDSCAPE PLAN
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 3 C AL/CP AG/NC
10.0
5.0
6.0
8.0
9.0
7.0
ENERGEX HV / LV CABLE AND CONDUIT PIT MINOR ENTRY SIGNAGE / FEATURE
Refer Architectural drawings Refer images for indicative concept
NOT FOR CONSTRUCTION
Section 5
2m CONCRETE FOOTPATH
Refer Specification Notes
RUFOUS STREET
3 .0
3 .0
3.0
RUFOUS LANE ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
TE
TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE TE QLD 4122
TE TE TE TE TE TE
TE
TE
T 07 3420 0006
TE
POOL RECREATIONAL BUILDING AND SHELTER
TE
M 0405 389 243
11 WALLUM 14 WALLUM
TE
Refer Architectural drawings 10 KAMALA 13 WALLUM 16 WALLUM E [email protected]
TE
TE
TE
TE
TE
TE
TE
12 MARRAM 15 MARRAM
TE
TE
TE
TE
TE
POOL LEGEND
TE
TE
TE
TE
9 LILY
TE
TE
TE
PROPERTY BOUNDARY
TE
TE
TE
As taken from Survey drawings
TE
TE
BIO-RETENTION BASIN
TE
TE
TE
TE
Refer Civil Engineering drawings RETAINING WALL
TE
TE
Refer Engineering drawings
TE
TE TE TE
PROPOSED CONTOURS
As taken from Civil Engineering drawings
6.0
5.5
5.0
4.5
6.5
EXISTING / PROPOSED SEWER
As taken from Survey / Engineering drawings
TE TE
PROPOSED RETAINING WALL
TE
EXISTING / PROPOSED STORMWATER
TE TE
As taken from Survey / Engineering drawings
TE
Refer Civil Engineering drawings
TE
4.5
PEREGIAN BEACH
TE
TE
TE
17 SALTBRUSH 1 HOTEL EXISTING TREES
TE
TE
8 LILY As taken from Survey plans
TE
TE
TE
TE
TE
TE
TE
6 MARRAM
6.5
SANDSTONE REGULAR STEPPERS
TE
TE
TE TE
Refer Specification Notes
TE
TE
7 KAMALA
TE
TE
5 KAMALA
TE
TE
TE
TE
TE
TE
TE TE TE TE TE TE
TE TE TE
TE
TE
SANDSTONE RANDOM STEPPERS
TE
Refer Specification Notes
TE
POOL RECREATIONAL BUILDING 18 SALTBRUSH 2
TE
TE TE TE
TE TE
TE
Refer Architectural drawings
TE
TE
4 KAMALA PROPOSED TIMBER GARDEN EDGE
TE
TE
TE TE
PROPOSED HARDSTAND 1 KAMALA Refer Specification Notes and Detail
TE
TE
Refer Architectural drawings 2 MARRAM
TE TE TE
TE
3 MARRAM
8.0
TE
TE
6.5
TE
BUILDING / ROOF OVER
TE
Refer Architectural drawings
TE
TE
PROPOSED POOL FEATURE STRUCTURE
TE
TE
Refer Architectural drawings POOL 19 SALTBRUSH 1
TE
FENCE TYPE A1 (100mm spacing)
TE
TE
Refer Specification Notes and Detail
TE
TE
TE
TE TE TE
FENCE TYPE A1 (50mm spacing)
Refer Specification Notes and Detail
6.0
TE
TE
FENCE TYPE A1 (1800mm high)
TE
STORMWATER DETENTION TANK
TE
20 SALTBRUSH 2 Refer Specification Notes and Detail
UNDER AND PLANTING / TURF OVER
TE
Refer Engineering drawings
5.5
5.0
TE TE
FENCE TYPE A2
Refer Specification Notes and Detail
BIN WASHDOWN &
GARDEN EQUIPMENT STORE
TE
FENCE TYPE B POOL FENCE
By others, refer Architectural drawings
EASEMENT
PROPOSED HOTEL
TE
FENCE TYPE C FIRE PROTECTION FENCE
COUNCIL
By others, refer Architectural drawings
TE
RESERVE
FENCE TYPE D1 BOUNDARY FENCE
Refer Specification Notes and Detail
SEWER EASEMENT
Redirected sewer
EXISTING SPECIALTY SHOPS FENCE TYPE D2 BOUNDARY FENCE ACOUSTIC
By others, refer Architectural drawings
EXISTING IGA
FENCE TYPE E BIN ENCLOSURE /
FRONT ACCESS
2m CONCRETE FOOTPATH
TE
Refer Specification Notes and Detail
Refer Civil Engineering drawings
TE
DAVID LOW WAY
TE
PROPOSED ACCESS GATE
Provide new access gate to match existing
NOTE:
EMERGENCY EGRESS ROAD For surface finishes, refer separate plans
TE
TE
EASEMENT
MASONRY BLOCK SCREEN FENCE
To bin store, refer Architectural drawings C 28/06/19 FOR TENDER
TE
B 28/06/19 FOR REVIEW
A 26/06/19 FOR REVIEW AND COORDINATION
TE
ISSUE DATE REASON
TE
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
PROPOSED RETAINING WALL PEREGIAN VILLAGE MARKETS
TE
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
Refer Civil Engineering drawings RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
TE
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
TE
GRAPHIC SCALE (m) 1:300 @ A1
0 1 5 10 15
BUSHFIRE SETBACK ZONE
ESSENCE OF PEREGIAN BEACH
215 DAVID LOW WAY, PEREGIAN BEACH
PROPOSED FENCES PLAN
JOB No. SHEET No. ISSUE DRAWN BY CHECKED BY
19.021 4 C AL/CP AG/NC
10.0
5.0
6.0
8.0
9.0
7.0
NOT FOR CONSTRUCTION
The text continues on section 6.