Original source · versioned page text
Bushfire Hazard Assessment
Very large file: it may take a few minutes
The original of this document is very large (32.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Bushfire Hazard Assessment 14 Serenity Close, Noosa Heads modelled inputs for potential fuel load (Map 7), maximum landscape slope (Map 8) and fire weather severity/FFDI (Map 9), respectively. PFI was calculated in accordance with Leonard et al. (2014a): 𝑃𝑃𝐹𝐹𝐼𝐼 = 0.62 𝑊𝑊 2 𝐹𝐹𝐹𝐹𝐹𝐹𝐹𝐹𝑒𝑒 (0.069𝜃𝜃) (Equation 1) Where: 𝑃𝑃𝑃𝑃𝑃𝑃 = Potential Fireline Intensity (kW/m); 𝑊𝑊 = Potential fuel load (tonnes/ha); 𝐹𝐹𝐹𝐹𝐹𝐹𝐹𝐹 = Fire weather severity/FFDI; and, 𝜃𝜃 = Maximum slope (degrees). Resulting PFI was then classified into one of three (3) potential bushfire hazard classes, as outlined in Table 1. TABLE 1: POTENTIAL BUSHFIRE INTENSITY CLASSES (SOURCE: LEONARD ET AL. 2014). Potential Bushfire Intensity Potential Fireline Intensity Very High 40,000+ kW/m High 20,000 – 40,000 kW/m Medium 4,000 – 20,000 kW/m 6.2.3 RADIANT HEAT FLUX Where modelling results indicated that the proposed development was located within a bushfire prone area and/or potential impact buffer, radiant heat flux and associated Bushfire Attack Level (BAL) was calculated according to the View Factor Method described in AS 3959:2018 (Standards Australia 2018). Separation distances for achieving the various BAL levels were calculated using the SPP Bushfire Asset Protection Zone Width Calculator (Queensland Fire and Emergency Services 2019), including inputs based on: ● Distance(s) between the closest edge of the proposed building and the edge of areas of potential fireline intensity, with radiant heat flux calculated consistent with the height of the adjacent vegetation, maximum flame angle and modelled flame lengths. ● Fuel loads derived from the post-development map of vegetation hazard classes and site-based survey (Map 7 and Appendix 2). ● Effective and site slope under the classified vegetation were calculated from the landscape slope map (Map 8). ● An FFDI of 48 based on the 5% AEP event as per Leonard et al. (2014) (Refer to Map 9). ● Flame width based on maximum front width perpendicular to the development footprint. Supplementary Method 2 input parameters and adopted values are listed in Table 2. 19 | 38
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.