APPROVED PLAN DESIGN INTENT OF PROPOSED WORKS: provide improved visitor and staff amenity to external areas - upgrade existing non compliant and stair and NOTES
51901.25.01 15 JULY 2025 access in courtyard 1. Remove defective and unsightly roof in level 1 courtyard 1 and balcony. Remove defective planter boxes in courtyard 1, and 2 Delta Panel colorbond surf mist
RF New roof corrugate to both sides. depth suitable
replace with upgraded planter boxes. Reduce areas of metal roof and increase batten and shaded poly carbonate pergola structures to courtyards 1 and to spans as described
4 3 2 1 prepare and paint all external walls
2. Provide shaded seating areas in both courtyards. Provide improved visitor access to courtyards 1 and 2. paint all existing
and exposed flashings, etc - 2 coats
external walls
external grade paint - white TBS
upgrade all soft scape area - external
to building footprint. remove all weeds
replace existing doors and unhealthy plants, provide new
ld landscape works
sleected native ground cover to all
areas, provide new 300 deep weed free
Exit top soil and 100 deep hoop pine mulch.
dp rf r removed 116m2
sh sh sh sh sh sh sh sh sh sh sh
rf n roof new 75m2
pgn pergola new 93m2
sc1
ld r landscape removed 39m2
ldn landscape new 23m2
sh
5 5
New stair, concrete with tile treads and
p2 cj sh
facia, frameless glass balustrade - facia
fixed , stainless steel handrails. Exit
cj
pl1 works subject to Minor change
timber
application shown blue dashed
1800
Timber seat, (spotted seats
Timber seat.
gum) Aluminium frame.
Exit
p1 pl2 150 rendered block seat
planter, drain to SW
d1 sh
new planter new planter
Timber seat, (spotted seat
cj timber gum) Aluminium frame. seat Exit
sign Exit
tgsi seats sh
COURTYARD 1
COURTYARD 2 dp sign
dp1 p1
kb kb kb ld kb
p2
ld 62 ld p1 p1 63 p1 s
ld rd
44 s
dp dp
Loading bay rd
New sunscreens ref detail
45 DD23
48 49 50 51 52 53 54 55 56 57 58 59 60 61
46
4 3 2 1 1
47
existing public footpath
0 2000mm 5000mm 10000mm
FLEXURE Pty Ltd USE FIGURED DIMENSIONS. ISSUE AMMENDMENT Title
CLIENT
THE BODY CORPORATE OF NOOSA CENTRAL DO NOT SCALE FROM THE date details
PLAN G NEW
DRAWINGS. CONFIRM ALL Date 16 June 2025
GRANT CALDER ARCHITECTURE AND URBAN DESIGN DIMENSIONS ON SITE PRIOR
TO CONSTRUCTION OR
FABRICATION. IT REMAINS Scale
PROJECT NOOSA CENTRAL STAGE 2, 6 Bottlebrush Avenue Noosa Junction - THE CONTRACTORS
RESPONSIBILITY TO ENSURE Drawn Grant Calder
21 Bursaria Street Peregian Beach
ph: 0488 084 184 ALTERATIONS AND IMPROVEMENTS - TENDER SET COMPLIANCE WITH ALL
RELEVANT CODES AND
email - [email protected] REGULATIONS IS Checked Grant Calder
Registered Architect- BOAQ 3112 MAINTAINED AT ALL TIMES.
Drawing No GC 138 TD 06 Issue - 0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.