Original source · versioned page text
Change to Jetty OPW18-0150 - Planning Report
Attached to the e-mail Change Operational Works Application - OPW18/0150.01 - 21 Wesley Court Noosa Heads.
O8 Large jetties, pontoons and S8.1 No solution provided Not applicable
wharves that are capable of The proposal relates to a
serving other uses, such as for minor modification to a
private recreational purposes, private jetty.
are not permitted.
14.165 Design, Construction and Safety – Jetties, Wharves and Pontoons
S9.1 The maximum width of a jetty, Complies
jetty head or associated walkway is No alteration to the
1.5m, except for at Noosa North existing approved jetty
Shore; structure is proposed. The
AND walkway wide will remain
as existing.
S9.2 For jetties on the Noosa North Not applicable
Shore, the maximum width of the jetty
head is 2m; AND
S9.3 The maximum length of a jetty
head is not more than 7m;
AND
S9.4 A pontoon head has a maximum Complies
width of 3m and a maximum length of No alteration to the
5m; (Refer Figure 14-31) existing approved jetty
structure is proposed.
O9 Prescribed tidal works are
Two small floating jetty
designed and constructed for
fenders are proposed
the sole purpose of providing
and attached to the
access to vessels and are sited
existing jetty. These
and designed to avoid—
fenders are to enable the
a) cluttering of watercourses;
safe and secure mooring
b) excessive traffic volumes
and access to a
within foreshore areas and
vessel/watercraft.
adjoining lands; c) conflicts with
uses on the foreshore and
S9.5 For “Y” and “T” shaped jetty Complies
adjoining lands; and
heads— a) a maximum area 10.5m2 The area of the existing
d) unacceptable risks to
excluding any walkway is provided; jetty will not be altered as
personal and public safety
and b) a walkway with a minimum a result of the proposed
length of 3m is provided (Refer Figure floating fenders and dry
14-32); storage pontoon.
S9.6 Gangways and walkways serving Complies
jetties and pontoons have at least No alteration to the rail is
one rigid handrail fitted and meet the proposed.
following—
a) For detached houses – a minimum
width of 750mm and a maximum
width of 1.5m;
b) For other residential uses –
i. the gangway for single berth
pontoons has a minimum width of
900mm;
ii. the gangway for multiple berth
pontoons has a minimum width of
RG Strategic Town Planning Report – Other Change Application 15