Attachment 3 -C_ Planning Scheme Assessment
Appendix C
Assessment Against the Planning Scheme – Medium Density Residential Zone Code
finishes and may incorporate solid translucent
screens, shutters, perforated panels or trellises
which have a maximum of 50% openings.
Editor's note—refer to figure AP3-1B
PO21 AO21.1
Mechanical plant, vehicle Communal outdoor recreational facilities Not applicable – non communal swimming pool as
manoeuvring, utilities and including swimming pools, spas and sports private individual pools are for each dwelling in the
communal outdoor courts are: proposed dual occupancy use.
recreation uses:
a. do not have an adverse a) setback at least 12 metres from the
effect on the amenity boundary of land in a residential zone
enjoyed by users of and screened by a 5 metre wide buffer
adjacent or nearby densely planted with trees and shrubs
premises through including species from 1 metre to 8
emission of noise, light, metres in height; or
fumes or smoke; and b) located internally to the arrangement
b. do not cause of buildings on the site; and
unreasonable c) not used between the hours
disturbance to local of 9:00pm and 6:30am the following
fauna through light or day.
smoke emissions.
AO21.2
For a lit sports court: Not applicable – no a lit court being proposed
a) the court is located at least 60 metres
from the external wall of an existing or
approved dwelling on adjoining or
nearby premises (as measured from
the centre line of the court); and
b) the vertical illumination resulting from
direct, reflected or other incidental light
emanating from the site does not
exceed 8 lux when measured at any
point 1.5 metres outside the boundary
and at any level from ground
level upward; and
c) any floodlighting is restricted to the
types that give no upward component
of light were mounted horizontally (i.e.
a full cut off luminaire).
AO21.3
Mechanical plant is-
Proposal able to comply.
a) located at least 2 metres from the side
or rear property boundaries;
b) where located at ground level,
screened by fencing 1.5 metres in
height or dense vegetation of at least
1.5 metres in width incorporating
grouped trees and shrubs with a
maximum separation distance of 1
metre measured from the centre of the
plant;
c) where located above ground level,
enclosed or screened such that it is
not visible from the street frontage nor
adjoining properties; and
d) visually integrated into the line and
plane of the building and roof design
and does not project beyond the
height or width of the building when
viewed from the street and adjoining
properties.