Appendix C
Assessment Against the Planning Scheme – Sustainable Building Design Code
application can be conditioned accordingly if
considered necessary by Council
PO6
Vegetation is incorporated into No acceptable outcome provided Complies – proposal plans by Quod are included in
the building design to create Appendix A
shade and cooling around
buildings.
Design Table 9.4.6.3 Criteria for assessment (part)
Performance Outcomes Acceptable Outcomes Compliance
Design
Site characteristics
PO7
Development and building siting is No acceptable outcome provided Can comply – proposal plans by Quod are included
responsive to Noosa Shire’s sub- in Appendix A and engineering plans have been
tropical climate and the site’s prepared by Arcos to demonstrate the ability to
characteristics including comply and are included in Appendix B.
topography, orientation, existing
vegetation and prevailing winds
Building design
PO8 AO8.1 Complies – proposal plans by Quod are included in
Development - Development provides a detailed assessment Appendix A and engineering plans have been
(a) orientates buildings and including supporting documents, demonstrating prepared by Arcos to demonstrate the ability to
windows to make the most of the means by which the design meets PO8. comply and are included in Appendix B.
prevailing winds, natural
ventilation and cross breezes; AO8.2
(b) maximises shade to east and Development demonstrates a measured
west walls; equivalent to a 5-star Green Star rating.
(c) contains an open and
permeable built form that Editor’s note—The publications QDesign and
connects indoor and outdoor QCompanion, prepared by the State of
spaces in an integrated Queensland, provide climate responsive design
design; principles for development in south east
(d) retains existing vegetation Queensland. Council encourages building and
and natural shading where landscape designers to incorporate best practice
possible; outcomes described in these publications to help
(e) incorporates passive building development comply with PO8.
design to reduce the need for
auxiliary heating and cooling;
(f) uses low toxic internal and
external building materials;
(g) uses natural light rather than
artificial light, and may include
skylights, atriums and light
wells;
(h) contains a minimum of two
openings per habitable room;
(i) provides a minimum floor to
ceiling height of 2.7 metres;
and
(j) enables efficient operation
and use of the building.
Editor's Note: Refer to
Figure 9.4.6.4.