PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA                                       10 MAY 2016


30.   All retaining walls must be designed and constructed in accordance with the planning
      scheme and must be certified by an RPEQ where exceeding 1.0m in height. All retaining
      walls that are publicly accessible and exceed 1.0m in height must be fitted with a
      commercial grade safety fence.
      Damage to Services and Assets
31.   Any damage caused to existing services and assets as a result of the development works
      must be repaired at no cost to the asset owner at the following times:
      31.1 where the damage would cause a hazard to pedestrian or vehicle safety,
           immediately; or
      31.2 where otherwise, upon completion of the works associated with the development.
      Any repair work which proposes to alter the alignment or level of existing services and
      assets must first be referred to the relevant service authority for approval.

RECONFIGURING A LOT CONDITIONS (REC15/0024)

Approved Plans
1.    Development undertaken in accordance with this approval must generally comply with the
      approved plans of development. The approved plans are listed in the following table unless
      otherwise amended by these conditions.
       Plan No.             Rev.   Plan/Document Name                               Date
       -                    B      Proposed Reconfiguration 33 & 35 Grant Street,   -
                                   Noosa Heads
2.    All lot numbering on the subdivision plan to be submitted to Council for compliance
      assessment must remain as shown on the Approved Plans.
Water & Sewer Connections
3.    An underground connection to reticulated water and sewerage must be provided to each lot
      in accordance with the standards and requirements of Northern SEQ Distributor–Retailer
      Authority (Unitywater).
4.    A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority
      (Unitywater) must be submitted to Council that certifies an underground connection to
      reticulated water and sewerage has been provided to each lot.
Community Management Statement
5.    Any proposed Community Management Statement required for the development pursuant
      to the Body Corporate and Community Management Act 1997 must be submitted to
      Council for endorsement at the same time as submission of the subdivision plan to Council
      for compliance assessment.
Electricity and Telecommunication Services
6.    Certification must be submitted to Council from all relevant service providers which certifies
      that the development has met the requirements of this Decision Notice and all applicable
      legislation at the time of construction.
Easements
7.    Reciprocal easements for access must be created with the lots. The easements must be of
      sufficient dimensions to encompass the paths of vehicles accessing the spaces,
      manoeuvring on site and exiting the site in a forward gear in a total of 3 movements.
8.    Reciprocal easements for support (or similar) must be created with the lots. The easements
      must be of sufficient dimensions to encompass the whole of the common dividing wall
      together with any necessary foundations.

                                                                                     Page 34 of 96
Log in to download the original file

2016-05-10 Planning & Environment Committee Agenda(PDF, 11MB).pdf · 11.4 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.