Skip to the record
Accept no imitations.

Council archive · source document

Letter - 6 Wyandra · MCU22/0058

of 3

Text shows just the words. Original shows the document exactly as it was published.

2.     Provide amended plans that include RL levels showing the maximum building
       height and identify natural ground level.
Response:
Pursuant to the revised plan set, RLs have been provided to the highest sections of the
building demonstrating compliance with maximum building height of 8.0m relative to NGL.
3.     Provide an amended stormwater management plan to demonstrate how
       stormwater will be collected and controlled. The amended stormwater
       management plan must be prepared by a suitably qualified person (RPEQ –
       Registered Professional Engineer of Queensland) and include, but not be
       limited to:
       a. a longitudinal section indicating the surface and invert levels, grades and
          lengths.
Response:
Please refer to the updated Storm Water Management Plan prepared by Recor.
4.     Provide an amended dimensioned driveway plan to demonstrate the location
       and angle of the vehicle driveways, crossovers and extent of transition. Note
       that Council is unlikely to support private retaining structures within the road
       reserve. The amended driveway plan must be prepared by a suitably qualified
       person (RPEQ – Registered Professional Engineer of Queensland) and
       include, but not be limited to:
       a. an amended design that is generally in accordance with RS-049 and RS-
          050;
       b. dimensions of the proposed driveways;
       c. levels and grades of the edges of the proposed driveways;
       d. longitudinal sections for each proposed driveway extending from the
          centreline of the formation in Safari & Wyandra Street to the proposed
          garage level; and
       e. the full extent of the transition to the adjoining areas of the verge
       Note: should the proposed driveway crossover be the only suitable location,
       provide sufficient detail to demonstrate that the safety of the existing
       conditions will not be compromised.
Response:
The civil package has been amended to provide driveway longitudinal section which
confirms finished and existing surface levels. Retaining structures would not be provided
within Council’s road reserve.
5.     Provide an amended earthworks plan to clarify if any works will be conducted
       within the road reserve to ease the verge between the road reserve and
       earthworks within the site. Note that Council is unlikely to support private
       retaining structures within the road reserve. The amended plan must be
       certified by a suitably qualified persons (RPEQ – Registered Professional
       Engineer of Queensland) and include, but not be limited to:
       a. demonstrate the full extent of any works of the transition to the adjoining
          areas of the verge
Response:
Please refer to the updated Bulk Earthworks Plan prepared by Recor. Earthworks Section,
A-A & C-C indicate minor works to facilitate new residential driveway. No retaining
structure are proposed within the road reserve.

---------------------------------------------------------------------------------------------------------------------
                                                                                                      Page 2 of 3

Used in these records

About this file

File size
308 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Letter - 6 Wyandra.pdf · 308 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.