Appendix D - Bushfire Risk Assessment and Management Plan

of 40
                         Ecological Natural Area Management

West bushfire attack
This modelled fire burns up-slope through Eucalyptus spp, Corymbia intermedia open forest to
attack from the west.
    • This attack uses fuel loads specified for VHC 9.1 Moist to dry eucalypt open forests on
       coastal lowlands of 17.5 t/ha surface fuel & 24.2 t/ha total fuel ,
    • Separation of the house from the hazard as required for an appropriate Asset Protection
       Zone and to assess radiant heat loads,
    • Slope in the vegetation = 1.60
    • Site slope = 1.60
    • Fire run = 40m leading to a reduction of the bushfire rate of spread to 0.40 of the full quasi-
       steady state rate of spread
    • Radiant heat shield height of 2m and the assessment uses radiant heat loads of greater
       than 40kW/m2 as the distance for BAL FZ as allowed in NSW RFS Planning for Bushfire
       Protection to take account of the shield and
    • FFDI = 53
North east bushfire attack
This modelled fire burns up-slope through Eucalyptus spp, Corymbia intermedia open forest to
attack from the north west.
    • This attack uses fuel loads specified for VHC 9.1 Moist to dry eucalypt open forests on
       coastal lowlands of 17.5 t/ha surface fuel & 24.2 t/ha total fuel ,
    • Separation of the house from the hazard as required for an appropriate Asset Protection
       Zone and to assess radiant heat loads,
    • Slope in the vegetation = 1.30
    • Site slope = 1.30
    • Fire run = 80m leading to a reduction of the bushfire rate of spread to 0.50 of the full quasi-
       steady state rate of spread
    • FFDI = 53
East bushfire attack from the treed parkland
This modelled fire burns up-slope through the treed parkland to attack from the north west.
   • This attack uses fuel loads specified for VHC 39.2 Low to moderate tree cover in built-up
      areas of 8 t/ha surface fuel & 8 t/ha total fuel ,
   • Separation of the house from the hazard as required for an appropriate Asset Protection
      Zone and to assess radiant heat loads,
   • Slope in the vegetation = 0.50
   • Site slope = 9.50
   • Fire run = 40m leading to a reduction of the bushfire rate of spread to 0.40 of the full quasi-
      steady state rate of spread
   • FFDI = 53
East bushfire attack from Notophyll Vine Forest
This modelled fire burns up-slope through the Notophyll Vine Forest to attack from the north west.
   • This attack uses fuel loads specified for VHC 3.1 Notophyll vine forest of 4.5 t/ha surface
      fuel & 4.5 t/ha total fuel ,
   • Separation of the house from the hazard as required for an appropriate Asset Protection
      Zone and to assess radiant heat loads,


Bushfire Risk Assmnt & Mngt Plan for a “Community housing” development at 55 Carpenters Rd, Cooroy   February 2022

                                                              23

Log in to download the original (Appendix D - Bushfire Risk Assessment and Management Plan.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.