Original source · versioned page text
Appendix D - Bushfire Risk Assessment and Management Plan
Ecological Natural Area Management
• Slope in the vegetation = 1.30
• Site slope = 1.30
• Fire run = 80m leading to a reduction of the bushfire rate of spread to 0.50 of the full quasi-
steady state rate of spread
• FFDI = 53
6.5 Map of the assessed Bushfire Attack Levels
This map of the assessed Bushfire Attack Levels for lots in the development shows that:
• All houses in the development can be built in the green areas which have a bushfire
construction requirement of BAL 12.5,
• Areas in the centre of the development have a radiant heat load less than 10kW/m2 and are
safe areas but”
• The escape route is through a BAL 19 area.
Figure 14: Map of the assessed Bushfire Attack Levels for lots in the development. All houses in the
development can be built in the green areas which have a bushfire construction requirement of BAL Areas in
the centre of the development have a radiant heat load less than 10kW/m2 and are safe areas.
6.6 Assessment of the minimum Asset Protection Zone
The minimum Asset Protection Zone that allows radiant heat loads less than 10kW/m2 and are
safe areas as required by Bushfire Resilient Communities
Bushfire Risk Assmnt & Mngt Plan for a “Community housing” development at 55 Carpenters Rd, Cooroy February 2022