Council archive · source document
Appendix E - Architectural Plans · MCU25/0053
Plans and drawings: the text below has words only, no drawings.
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
GENERAL NOTES
VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING WORK. DO NOT SCALE FROM DRAWING.
COPYRIGHT
THE COPYRIGHT OF THESE DOCUMENTS AND ALL WORKS EXECUTED FROM THESE DOCUMENTS
SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR ON CREATION VEST IN THE ARCHITECT.
THESE DOCUMENTS MAY ONLY BE USED TO PRODUCE THE PROJECT FOR THE CLIENT AND IN THE
LOCATION DESCRIBE HEREON
9 CONSULTANT ISSUE 02.05.25
8 CONSULTANT ISSUE 30.04.25
7 MINOR UPDATES 24.04.25
6 BOAT STORE REM OVAL 16.04.25
5 STRUCT UPDATES 09.04.25
4 UPDATED BASEMENT, STRUCTURE 11.03.25
3 GENERAL UPDATES 30.01.25
1 2 2 1
40.03 40.02 40.02 REV DESCRIPTION DATE
40.03
1 2 3 4 5 6 7 REVISION SCHEDULE
LEGEND
CODE DESCRIPTION
AP ACCESS PANEL
BAL-02 BALUSTRADE TYPE 2
BLK-200 190mm CORE-FILLED BLOCKWORK
CNC-PF CONCRETE - PAINT FINISH
COL-A CONCRETE COLUMN - PAINT FINISH
7292 3380 8500 7160 11435 6000 4690 7000 GLW-01
GRD-01
GLASS WALL
PIL CONCRETE PILING
SPA SPA BATH
TFL 01
VB VANITY BASIN
WC TOILET SUITE
2230 600 550200 3600 200 19895 200 7300 3000 200550 600 2040 6250 600150
200
2005
2005
+ RL 1.300
POOL
3155
3355
PIL BAL-02
A A
200550 600
DOOR LEGEND
VOID CNC-PF POOL WINDOW VOID LEVEL OR UNIT NUMBER
200
***
3000
DOOR NUMBER D**
BLK-200 BLK-200
550
2000
STORMWATER PUMP SAUNA
2360
POOL EQUIP FT-01
GATE
WINDOW/GLAZING LEGEND
STATION UNDER CNC-BF SERVICE
CNC-BF
W** L**
200
COL-A
4715
WINDOW NUMBER LEVEL NUMBER
PLANT HT BLK-200 HT
BLK-200 CNC-BF SEWER LINE CLEARANCE ZONE
HOSE TAP SPA MIN. 1200 CLEAR 450 COVER WALL TYPES
2
40.01
11210
PARTITION STUD WALL WITH LININGS AS NOTED,
3660
AP STORAGE SPA REFER ARCH. SCHEDULES
BLK-200 CNC-PF CONCRETE/PRECAST WALL/PANEL. FINISHES AS
200
1500 5600 300 8400 300 2800 1185 3010
SEWER LINE
VOID
SPA NOTED, REFER ARCH. SCHEDULE
5500
5500
TYP
TFL 01
BLK-200
CONCRETE/PRECAST WALLPANEL WITH LINING.
18215
BIN
1995
200
FINISHES AS NOTED, REFER TO ARCH. SCHEDULE
CNC-BF
COL-A COL-A COL-A SHR CONCRETE BLOCK WALL WITH LINING.
FINISHES AS NOTED, REFER ARCH. SCHEDULE
VOID
FT-01 RL 1.200
200
1990
VB WC
BLK-200 1 2 3 4 5 6 PIL CONCRETE BLOCK WALL. FINISHES AS NOTED, REFER
18110
GLW-01 ARCH. SCHEDULE
ALUMINIUM FRAMED GLAZING SUITE. REFER TO
2690
GARDEN ELEVATIONS AND DETAILS.
60 1940
CNC-BF
SERVICE PENETRATION ZONE
B B
140 60
200
GARAGE 1
140
2
CNC-PF VB
BLK-200
2000
3
GENERAL NOTES:
6200
RL -0.700 +
AP 4 LIFT PDR
5 WC CELLAR 1. REFER TO ARCHITECTURAL & INTERIOR FINISHES SCHEDULES FOR
6
FT-01
4400
7
SYSTEMS, LININGS & FINISHES.
4 8
4260
GRD-01 GLW-01 CNC-PF WT-21 2. ALL WET AREAS TO HAVE WET AREA PLASTERBOARD OR EQUAL.
1 SEWER PUMP 8
GATE 3. FALLS TO SCREED TO BE PROVIDED TO WET AREAS TO COMPLY WITH
40.01
DRIVEWAY STATION UNDER 9
10 AS1428.1 GRADES FOR BATHROOM AND SHOWER FLOORS.
COBBLESTONE 11 UPPERMOST FFL NOTED ONLY.
2950
12 13 14 15 16 17 18
4. ALL WALLS AND PARTITIONS TO ALLOW FOR STRUCTURAL
200
BLK-200 HT DEFLECTION AND STRUCTURAL MOVEMENT.
MH 5. REFER TO NCC REPORT & ACOUSTIC REPORT FOR ACOUSTIC
C C
450 550
VOID REQUIREMENTS. ACOUSTIC LINING TO ALL TIMBER FLOORS.
450 550
BAL-02
450
6. REFER TO NCC REPORT & ESD REPORT FOR THERMAL
200
REQUIREMENTS.
2500
PIL 7. FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
+ RL 1.300 WITH AS2419 AND AS2441.
1500
1500
1500
8. VERIFY ALL DIMENSIONS/SETOUTS ON SITE PRIOR TO
BLK-200 CONSTRUCTION.
9. REFER TO CONSULTANT DRAWINGS FOR SERVICES LOCATIONS AND
SIZES. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION.
4928 3980 200 3600 200 20085 110 1100 1800 1515 110 5675 200550150450 2040 4800 200 2000 10. REFER TO ELEVATIONS FOR FURTHER FINISHES AND PANEL SETOUT
INFORMATION.
11. ALL STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED, REFER
STRUCTURAL ENGINEERS DETAILS
12. OVERFLOW LOCATIONS TO BE COORDINATED WITH HYDRAULIC
ENGINEER, OVERFLOW REQUIRED BY THE HYDRAULIC ENGINEER TO
BE COORDINATED WITH THE ARCHITECT.
13. REFER TO ELEVATIONS FOR FACADE SCREEN SET-OUT.
14. ALL EXPOSED CONCRETE WALLS/COLUMNS TO BE CLASS 2 FINISH.
ANY BACK OF HOUSE CONCRETE WALLS/COLUMNS TO BE CLASS 3
FINISH.
15. DISCONTINUOUS CONSTRUCTION AS REQUIRED TO COMPLY WITH NCC
REQUIREMENTS.
16. ROOF VENTILATION REQUIRMENTS BY OTHERS. CONTRACTOR TO
VERIFY PRIOR TO CONSTRUCTION.
1 2 3 4 5 6 7
bureau^proberts PTY LTD
ABN 53 073 087 993 ACN 073 087 993
LEVEL 14, 100 CREEK STREET, BRISBANE QLD 4000, GPO Box 3204 QLD 4001
P: 07 3221 0672 F: 07 3221 0683 EMAIL : [email protected] www.bureauproberts.com.au
CLIENT:
SEYMOUR GROUP
PROJECT:
NOOSA RESIDENCE
ADDRESS:
7 NOOSA PARADE
DRAWN BY: NORTH:
TH
CHECK BY:
JC
PROJECT
ARCHITECT JC
DESIGN
ARCHITECT AB
SCALE:
5 1 : 100 [A1]
DRAWING TITLE:
G.A. BASEMENT PLAN
CAD FILE REF: DATE:
C: \_Revit Local\24048_7 Noosa Parade_B.A_JasonC9U8GC. rvt
02.05.25
PROJECT NO: PHASE: DRAWING NUMBER: REVISION:
24048 B.A. AR 21.01 9
2/05/2025 4:56:41 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.