GENERAL NOTES
VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING WORK. DO NOT SCALE FROM DRAWING.
COPYRIGHT
THE COPYRIGHT OF THESE DOCUMENTS AND ALL WORKS EXECUTED FROM THESE DOCUMENTS
SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR ON CREATION VEST IN THE ARCHITECT.
THESE DOCUMENTS MAY ONLY BE USED TO PRODUCE THE PROJECT FOR THE CLIENT AND IN THE
LOCATION DESCRIBE HEREON
8 CONSULTANT ISSUE 02.05.25
7 CONSULTANT ISSUE 30.04.25
6 MINOR UPDATES 24.04.25
5 STRUCT UPDATES 09.04.25
4 UPDATED BASEMENT, STRUCTURE 11.03.25
3 GENERAL UPDATES 30.01.25
2 CONSULTANT COORDINATION 16.01.25
1 2 2 1
40.03 40.02 40.02 REV DESCRIPTION DATE
40.03
1 2 3 4 5 6 7 REVISION SCHEDULE
LEGEND
CODE DESCRIPTION
AFG-SD1 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 4-PANEL XXXO
AFG-SD2 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 3-PANEL XXO
BAL-02 BALUSTRADE TYPE 2
BLK-200 190mm CORE-FILLED BLOCKWORK
CNC-PF CONCRETE - PAINT FINISH
7292 3380 8500 7160 11435 6000 4690 7000 COL-A
COL-B
CONCRETE COLUMN - PAINT FINISH
STEEL COLUMN
VB VANITY BASIN
WC TOILET SUITE
26945
2000 SIDE BOUNDARY FENCE
HT
4
2005
75
RL 2.700 + + RL 1.300
R9
8 7 6 5 4 3 2 1
2005
740 5050
POOL RL 0.800 +
BAL-02
A BAL-02
A
DOOR LEGEND
890
ENTRY BBQ SK BAR
PLANTER
PAVING HT COL-A COL-A LEVEL OR UNIT NUMBER
550 2425 ***
3000
3000
DOOR NUMBER D**
RL 2.300 RL 2.100 + GATE HOSE TAP HT BAL-02
200
GATE BAL-02 GATE
WINDOW/GLAZING LEGEND
9
564
COL-A W** L**
COL-A
LIVING
R2
GATE WINDOW NUMBER LEVEL NUMBER
FT-01
COL-B
2 FFL 2.725 WALL TYPES
AFG-SD2
AFG-SD2
40.01
11210
PARTITION STUD WALL WITH LININGS AS NOTED,
SEWER LINE
REFER ARCH. SCHEDULES
7000
BAL-02
CONCRETE/PRECAST WALL/PANEL. FINISHES AS
POOL TERRACE
FRONT COURT NOTED, REFER ARCH. SCHEDULE
BLK-200
COL-A EX-FT-01 RL 1.300
LANDSCAPING
COL-B FFL 2.650 CONCRETE/PRECAST WALLPANEL WITH LINING.
FFL 2.725 DINING FINISHES AS NOTED, REFER TO ARCH. SCHEDULE
KEY TMF-01 CONCRETE BLOCK WALL WITH LINING.
2024
1800 FRONT BOUNDARY COL-B FINISHES AS NOTED, REFER ARCH. SCHEDULE
DROP BLK-200 BAL-02
FENCE AND GATE FFL 2.700
COL-B
REAR TERRACE CONCRETE BLOCK WALL. FINISHES AS NOTED, REFER
200
COL-B EX-FT-01 ARCH. SCHEDULE
HT SHR
1000
SK ALUMINIUM FRAMED GLAZING SUITE. REFER TO
SHR COL-B FFL 2.700 ELEVATIONS AND DETAILS.
WT-20
WC
HALL
ROBE
2500
KITCHEN
1100
RL 2.700 TMF-01
WT-20
2265
790 BLK-200 ENS 4 ENS 5 TMF-01
SERVICE PENETRATION ZONE
ROBE
FT-01 COL-B
B WC FT-01 B
60095 600
1 1
VB VB
BLK-200
2 2
200
1600
3
BLK-200 4
3
LIFT CNC-PF
WT-20 BLK-200 GENERAL NOTES:
4
5
5
6
SCULLERY 1. REFER TO ARCHITECTURAL & INTERIOR FINISHES SCHEDULES FOR
WT-12
965
7 6
4400
OUTDOOR ROOM FAMILY STAIR FT-01 SYSTEMS, LININGS & FINISHES.
BLK-200
8 7 COL-A
EX-FT-01 TMF-01 FT-01 BLK-200 2. ALL WET AREAS TO HAVE WET AREA PLASTERBOARD OR EQUAL.
AFG-SD1
9
1 8
3500
DRIVEWAY BED 4 BED 5
60095 600
10
9 VB BLK-200 SK BAL-02 GATE 3. FALLS TO SCREED TO BE PROVIDED TO WET AREAS TO COMPLY WITH
40.01 14 7 COBBLESTONE 4 CPT-01 CPT-01 10 PDR WC WT-20 AS1428.1 GRADES FOR BATHROOM AND SHOWER FLOORS.
FT-01 BLK-200
UPPERMOST FFL NOTED ONLY.
3645
11 LT
12 13 14 15 16 17 18
4. ALL WALLS AND PARTITIONS TO ALLOW FOR STRUCTURAL
LAUNDRY DEFLECTION AND STRUCTURAL MOVEMENT.
965
BLK-200 BLK-200
FT-01 MH PLANTER 5. REFER TO NCC REPORT & ACOUSTIC REPORT FOR ACOUSTIC
100
C RL 2.560
COL-B COL-B COL-B HT BAL-02
C REQUIREMENTS. ACOUSTIC LINING TO ALL TIMBER FLOORS.
280 600
HT WM BAR SK BBQ HT 6. REFER TO NCC REPORT & ESD REPORT FOR THERMAL
BLK-200
200
REQUIREMENTS.
2500
0
SIDE COURT DRY COURT
2500
8 7 6 5 4 3 2 1 7. FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
WITH AS2419 AND AS2441.
1500
1500
RL 2.700 + + RL 1.300
8. VERIFY ALL DIMENSIONS/SETOUTS ON SITE PRIOR TO
HT CONSTRUCTION.
9. REFER TO CONSULTANT DRAWINGS FOR SERVICES LOCATIONS AND
2000 SIDE BOUNDARY FENCE
SIZES. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION.
200 3995 200 3995 200 2010 200 2770 2890 200 3795 3540 200 1100 200 1400 200 1100 125 2200 200 2450 125 1100 200 3190 10. REFER TO ELEVATIONS FOR FURTHER FINISHES AND PANEL SETOUT
INFORMATION.
11. ALL STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED, REFER
STRUCTURAL ENGINEERS DETAILS
12. OVERFLOW LOCATIONS TO BE COORDINATED WITH HYDRAULIC
ENGINEER, OVERFLOW REQUIRED BY THE HYDRAULIC ENGINEER TO
BE COORDINATED WITH THE ARCHITECT.
13. REFER TO ELEVATIONS FOR FACADE SCREEN SET-OUT.
14. ALL EXPOSED CONCRETE WALLS/COLUMNS TO BE CLASS 2 FINISH.
ANY BACK OF HOUSE CONCRETE WALLS/COLUMNS TO BE CLASS 3
FINISH.
15. DISCONTINUOUS CONSTRUCTION AS REQUIRED TO COMPLY WITH NCC
REQUIREMENTS.
16. ROOF VENTILATION REQUIRMENTS BY OTHERS. CONTRACTOR TO
VERIFY PRIOR TO CONSTRUCTION.
1 2 3 4 5 6 7
bureau^proberts PTY LTD
ABN 53 073 087 993 ACN 073 087 993
LEVEL 14, 100 CREEK STREET, BRISBANE QLD 4000, GPO Box 3204 QLD 4001
P: 07 3221 0672 F: 07 3221 0683 EMAIL : [email protected] www.bureauproberts.com.au
CLIENT:
SEYMOUR GROUP
PROJECT:
NOOSA RESIDENCE
ADDRESS:
7 NOOSA PARADE
DRAWN See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.