Council archive · source document
08/0170 - Response to Information Request [As Published] · 132008.170
ALD 8 EGRET STREET PERIGIAN BEACH FOR ALTUM CONSTRUCTIONS QLD GENERAL NOTES Water Supply and Scnitary Drainage has been designed and shail be constructed in accordance with the Q'Id Standard Sewerage Law, Q'td Standard Water Supply Low, the National Plumbing and Drainage Code AS 3500., all relevant Australian Standards, and the requirements of the Local Authority. These Drawings are diagrammatic only and shall be read in conjunction with all relevant Architectural and other consultants drawings and specifications and other written instructions that may be issued during the course of the contract. Any discrepancies shall be referred to the supervising officer for decision before proceeding with the work, Contractor shall verify all fixture iocations, invert levels, surface levels, and cover to pipes are correct and obtainable prior to commencement of the work. The exact location of existing, ond proposed services, shall be verified with the relevant Authority, or other trades as applicable. Fire stop collars to be used on all plastic pipework penetrating fire resistant construction. SANITARY DRAINAGE Underground pipework shali be 100 dia. PVC DWV, min grade 1:60 U.N.O. Suspended Pipework shall be PVC class DWV. Trade waste pipework to grease trap suspended shall be "Coesprene” or HDPE. Underground shal! be vitreous clay or HDPE. Trade waste pipework to oil separator shall be HDPE, or Vitreous clay with “Nitrile” rubber rings. CLeanouts or inspection openings brought to surface in paved or concrete areas, or within buildings to have brass caps. STORMWATER DRAINAGE Underground pipework shall be 100 dia PVC class SW min grade 1:100 U.N.O. Downpipes shall be 100 Dia PVC class SW. Rainwater outlets (RWO) and planter outlets (PO) shall be "Gatic Wade” or simitar, with membrane clamp where required. WATER SUPPLY Pipework shall be according to AS4020 for example ABS (acrylonitrite stytrene), PP (Poly propylene) or PE (Polyethylene) or copper UNO, Water supply pipework shall be 20 dia UNO. Exception: one fitting only may be 15 dia. max. fength 3000 mm. Hot water pipework shall lagged. Hot water recirculating lines to be insulated with 20mm “Armaflex’ or similar. Provide tempering valves on hot water to personal hygiene fixtures. Underground copper pipework shall be "Kemlagged” or otherwise protected. Underground pipework not under concrete slab may be polypipe class PN20. one size larger than shown. Exposed pipework in amenities areas, sha!l be chrome plated, Where water meters are installed within tennancies, provide remote readout adjacent to Electrical meters, or in a position as indicated by the Architect. BACKFLOW PREVENTION Provide hose connection vacuum breakers to all hose cocks Provide RPZD to any irrigation connections. COVERS & FRAMES Covers subject to vehicular traffic to be 535 dia, cast iron, medium duty UNO. Covers in grassed or cone. creas to be 535 dia. cast iron, concrete infill light duty. Covers in paved areas to be 600 sq. Infill to match paving pattern. Covers in tiled areas to be as for paved areas with brass edging. Concrete infill covers to be stamped "SWD" or "SEW" as appropriate. Covers & Frames to be "Faston” or equal approved. GRATINGS Gratings for storm water to be “faston, Gatic” or approved equal. Duty to motch manufacturers recommendatians for loading condition. Trench grate to be transverse bar. Floor waste grates to be chrome plated brass LEGEND Non potable water ® Diameter Existing water €.0.8. Cleanout to surface Existing sewer Cd Capped junction Existing storm water cv Conroi valve Existing house drain cs ceoners, sink i i cw o later vont pe nose DAP Duct access panel Cold Water Ocv Double check valve Een Eccentric Enlarger Hot water Elev Dge Evevcted Drainage Storm Water Drainage Ent Enlarger Fire FC False ceiling agi Agi Drain FH Fire Hydront FHR Fire hose reel . FFL Finished floor level Cold Water Riser FU Fixture units Down Pipe GIT Grease Interceptor trap 5 GP Gully pit ) Stack CMH Gully Man Hote Vent Pipe gv Gate valve @) o HW Hot water GQ) Group vent HCB House connection branch Educt vent HD House drain @®) o HL High level @ Induct vent Ic ingpection Chamber Hot water riser re Invert Level ° i io Inspection opening Fire Dropper ios inspection Opening to Surface (8) o Fire Riser K&C Kerb & Channel CB) ° ; MH Manhole (6) Non potable riser NRV Non return valve a ( » _— PB Path box woter meter PLV Pressure fimiting vaive % PO Planter outiet v falve Cock RPB Real Property Boundary — ne ose Coc RPD Real Property description —_— een £ tri \ RPZD Reduce Pressure Zone device ecentric enlarger Rwo Rain water outlet eae en Enlorger RWH Rain woter head SD Sanitary Drcinage E) ORG Overflow Relief Gully SL Surface Level S Square — WC Water okt Safe Tray Closet SWD Storm water drain . t/td Trapped Tundish (45 sk Sink TG Test gate td Tundish UT Laundry tub Tous Trench grate transverse bor TOU) Trench grate longitudinal bar wm Washing T.MV, Thermostatic mixing valve Machine TV Tempering valve Fwo Floor Waste u/g Underground gully u/s Under slab . u.n.o. Unless noted otherwise Bn Basin WS Water supply Shower HWS Hot water system FHR Fire Hose Reel C) cs Cleaners Sk (J e S (7 }} bth Bath S<] ——— Shr Et CH (h SIRS Site 1083.8m? Roof 257.8m ? Driveway 274.1m? Landscape 551.9m? New impervious 531.9m? CATCHMENT AREAS Note: All kitchen, laundry & bathroom fittings and toilets to comply with the AAA Water Conservation Rating System as defined by AS/NZS6400. Provide flow restrictor valves where necessary to taps and shower roses. The flow shall not exceed a maximum of 9L/min Provide.-.a°@80 sub—soil drain at the base of retaining wall, as per structural engineers Specification and join to GP6 with #100 PVC. Sif Provide a #80 sub-soil drain at the base of retaining wall, as per structural engineers Specification “and join to GP6 with #100 PVC. TG 2 & os 5 Q a a aa ae Note: Do not scale from these drawings. Do not rely on these drawings for alignment and levels of all existing infrastructure. It is the obligation of the contractor and/or plumbing contractor to survey all existing services prior to construction LOCALITY PLAN Provide a #80 sub-—soil drain at the base of retaining wall, as per structural engineers Specification and join to GP6 with 100 PVC. | daybed media f teach shower fayhe BASEMENT STORMWATER DRAINAGE. 7” ~CP6 ~ ” ” ” 7 Provide a 980 sub-soil drain at “eo the base of retaining wall, as per ” structural engineers Specification “ ne and join to GP6 with #100 PVC. ae Lot 293 DRAWINGS 1901-1 - 1901-2 - Pollution Control iaqnagemen 1. To be responsibility of Managernent 2. To list all in flow filtering devices like leaf eaters at DP’s and other filters 3. To keep and maintain a log of cleaning 4. To clean devices including first flush storage tank —as to manufactures specification on PLOT—93112 GENERAL NOTES & LEGEND SITE STORMWATER DRAINAGE Plan (PCMP —minimum quarterly, but monthly in rainy season —after each major rainfall event 5. To inspect and clean tanks minimum once yearly 6. To install and maintain pump and fixtures for reuse/watering/irrigation as to manufactures specification X AERIAL PHOTO COUTESY NOOSA SHIRE COUNCIL Amd Description Dote —r- Issue LC Notes Date For Development Aosrowa| x betes For Building Approval For Tender | T For Construction jAs_Constructed contact: Reinhold Koenning MigAust RPEQ No 7023 PO Box 1176 Buddina QLD 4575 7 email: [email protected] www.conhyd.com PH: 5444 8645 FX: 5444 8224 CUENT : s ALTUM CONSTRUCTIONS ARCHITECT : SPARKS ARCHITECTS NEW DUPLEX RESIDENCE 8 EGRET STREET PERIGIAN BEACH QLD DRAWING TITLE: ~| PROJECT: i GENERAL NOTES, LEGEND ’ & STORM WATER DRAINAGE Design| RK [Checked [pete [20-3-08 | Dwg. No. 1 of 2 | 1901-1 Lot 293 on pilot 93112 SCALE : 1:100 ON At ULN.O. RPD:—
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0170 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 756 KB (small file)
- File type
No other editions are linked here.