NOTES:
1
Provide second stage treatment, first flush and
silt trap charnber, 61050 concrete as per detail.
Provide First stage treatment, baffled Gross
Pollutant trap (BGPT) Type; "FOX" or
>
Concrete ring
Precast
components
-
“CLEARMATE” with 300mm riser, as per detail.
Provide a 450mm wide trafficable grated drain
and discharge to BGPT above strainer basket.
Provide a new 1050 concrete standard SW
manhole over existing SW and connect a 6300
RCP. For details refer to Sunshine Coast
Regional Council stondard drawings.
Provide a stormwater harvesting tank with a
minimum volume of 15,000 litres.
600mm DIA cast iron cover
and frame. Refer Note 11
1050 nom
C>
Top of access chamber
100 above finish surface but
flush with pavements.
i
max
350
2000 max.
MH-1/1
SL15.800
1L14.600
See note—1
of i
1H 4150 ovat
A trom cer.
#300 FRC
BGPT SL15.900
OUTLET: IL15.300
See note-2
Detention and infiltration
chamber, standard, concrete
Precast, 91050 internal, depth
1350, with heavy duty lid
$L15.800 |
VY
=p
LT 4 9150
7 O
$225 21050 ey] | #300 RCP
1L15.000
\ 7 IL14.900
r / to SW Manhole \V/
IL14.600
plo Geotextile
Vv st eee
5 HI
| IQ
I | — 1L14.300 |S
(TS
%225 perforated PVC. Coarse gravel
wrapped in geotextile min size 80mm
STORMWATER ON SITE SILT TRAP, INFILTRATION & OVERFLOW SYSTEM SCALE: NTS
GROUND FLOOR & SITE
STORMWATER DRAINAGE
FOX BAFFLED GROSS POLLUTANT
COLLECTION TRAP DETAIL WITH RISER
ATTACHED TO 450mm_ TRENCH GRATE
NTS
Sw. Sw- sv
Levels subject to survey.
Saw cut at existing
Pavement refer pavement
Project documentation
for detail
50mm Asphaltic paving
Rot
S
Existing
pavement
Pavement Deep
lift asphaltic concrete
No fines concrete backfill
(8 parts 10mm NOM size
aggregcte to 1 part cement)
Coarse or
36
fine bedding
EXCAVATION, BEDDING AND BACKFILLING
OF STORMWATER DRAINAGE PIPES
SCALE 1:20
Notes:
1. Selected backfill in all cases shall be carried through to the wings and
continued 300 thick for the length and height of wings.
2. Bedding compaction (Compacted selected fill/sand bedding)
Cohesive material — 95% standard compaction
Non-cohesive material — density indes of 7Omin, refer AS1289.E5.1
Sand — compact by flooding and use of vibrators.
3. Backfill compaction
Compacted gravel (300mm) layer under road pavement 95% standard compaction
Compacted ordinary fili/CBR15 Gravel 90% standard compaction — below 300mm zone.
Compacted backfill — ot footpaths/private property 90% standard compaction.
MAX. densities determined by standard compaction tests to AS1289.5.1.1.
4. Type U & Type H1 to conform to AS3725.
5. Dimension A can be reduced to 150min for non mechanical
compaction of backfill.
DETAIL MH 1/2
Description Date
—
| |
L
—
Issue Notes Date
For Development Approval] x [ 20-3-08
For Building Approval |
For Tender
For Construction |
As Constructed t |
Construction Hydraulic
Bullding Service Engineers :
-
CLIENT : 4
contact: Reinhold Koenning MigAust RPEQ No wa |
PO Box 1176
Buddina QLD 4575
email: [email protected] PH: 5444 8645
www.conhyd.com FX: 5444 8224
ALTUM CONSTRUCTIONS
ARCHITECT :
\. SPARKS ARCHITECTS
PROJECT:
NEW DUPLEX RESIDENCE
8 EGRET STREET
PERIGIAN BEACH QLD
DRAWING TITLE:
SITE STORMWATER
DRAINAGE
Design| RK [checked | [pete [20-3-08 | Dwg. No.
SCALE : 1:100 on Ar uno] 2 oF 2 | 1901-2
RPD:— Lot 293 on plot 93112
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0170 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 756 KB (small file)
- File type
No other editions are linked here.