Site Plan - New Jetty
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn drawing index
01 SITE PLAN
02 FLOOR PLAN, FLOOR FRAMING PLAN & TYPICAL SECTION
Project: NEW JETTY
Client: MARK STEINERT
N o 1 3 G O D W I N P L A C E . P E L I C A N W A T E R S . Q L D . 4551
Address: No. 48 MASTHEAD QUAY, NOOSAVILLE Q 4566 0409 612 231 | [email protected]
WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721
Lot 610 ON RP883864 DRAWING NAME REV DATE
COVER SHEET C 11/08/22
A3
DESIGNER PROJECT NO
SD KUNKEL 22.033
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 2 pages
Page 2
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
ary
d bound
Projecte 5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
5.079m
the Designer for confirmation. Contractor shall verify all
14090 from front
dimensions on site prior to construction.
property details
131°04
"
44°07'10
No. 48 Masthead Quay
9603
Noosaville QLD 4566
'10"
of revetment wa
42.121m
Noosa Shire Council
13.078m
Locality - Noosaville
13293
Lot 610 on RP883864
9112
ll to centre
Site Area - 893m²
Zone - Low Density Residential
of jetty at revetm
wm Precinct - N/A
wm Overlays - Acid Sulphate Soils
proposed - Flood Hazard
- Landslide Hazard
11.598m
ent wall
masthead
jetty
canal
quay
144°18'30"
ent wall
320°22'35"
8783
Existing stone stairway
jetty at revetm
fh
elec
157°33'0"
l to centre of
mh telstra
elec
revetment wal
NSC sewer main
16058
Existing revetment wall
nt of
40.562m
16860 from fro
251°07
'10"
13.078m
Projecte
d bo undary
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
N o 1 3 G O D W I N P L A C E . P E L I C A N W A T E R S . Q L D . 4551 SDK SDK N3 MARK STEINERT NEW JETTY SITE PLAN 01 C 22.033 A3
RTH
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NO
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
No. 48 MASTHEAD QUAY, NOOSAVILLE Q 4566 SHEETS IN SET SCALE
C 11/08/22 SDK CONSTRUCTION ISSUE Lot 610 ON RP883864 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Page 3
Property boundary
7500 750 750
250mm deep
420
750 420
Property boundary
kayak step
2540
5080
5080
Rigid handrail to 200x50x3mm aluminium
comply with Noosa floor joists @ 450mm crs max.
7000
Shire Council regulations
Composite decking over 2/152x62x8mm structural
'c' channel headstocks per pile
Do not fix jetty
2540
to revetment wall 250mm deep fascia
750
jetty
1500
420 750
420 750
250mm deep
420
kayak step
1500 6000 1500 Do not fix jetty 1000 2415 2420 2415 750 315 dia. pvc insitu piles
to revetment wall to engineers detail
9000 1500
Joists to butt into headstocks aluminium framing sizes to engineers
Existing stone stairway with site welded connection design & detail
Existing revetment wall floor plan Existing revetment wall floor framing & footing plan
1 1 : 100
2 1 : 100
7500
300 300 notes
1. Contractor to confirm exact siting and orientation
prior to construction setout.
70
300
10 dia. rod 2. All building setout & confirmation of setbacks &
height to be carried out by a Licensed Surveyor.
1000
32 chs polished stainless 3. Do not scale off drawings, use figured dimensions
steel handrail & posts only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
Composite decking over 4. Levels & services locations to be confirmed prior to
construction.
300mm deep composite
decking fascia 5. Termite protection to be provided in accordance with
Boundary line
clause 3.1.4 of the BCA (QLD variation) & AS3660.1.
200x50x3mm aluminium handrail detail Contractor to provide protection information for building
floor joists @ 450 crs max. 3 1 : 50
development application.
legend
- composite decking over
Do not fix jetty to Floor joists site welded to Denotes dimension to centre line
revetment wall headstocks to engineers detail 2/152x62x8mm structural Denotes dimension to outside face
'c' channel headstocks per pile
floor areas
300mm deep composite decking jetty area 21.8 m²
fascia to perimeter total area 21.8 m²
Existing revetment wall
Headstocks to piles to signatures
engineers detail owner/s
315 dia. pvc insitu piles
to engineers details
section builder
4 1 : 50
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
N o 1 3 G O D W I N P L A C E . P E L I C A N W A T E R S . Q L D . 4551 SDK SDK N3 MARK STEINERT NEW JETTY FLOOR PLAN, FLOOR FRAMING PLAN & 02 C 22.033 A3
RTH
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NO
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
No. 48 MASTHEAD QUAY, NOOSAVILLE Q 4566 TYPICAL SECTION SHEETS IN SET SCALE
C 11/08/22 SDK CONSTRUCTION ISSUE Lot 610 ON RP883864 2 As indicated
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies