Original source · versioned page text
Site Plan - New Jetty
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
ary
d bound
Projecte 5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
5.079m
the Designer for confirmation. Contractor shall verify all
14090 from front
dimensions on site prior to construction.
property details
131°04
"
44°07'10
No. 48 Masthead Quay
9603
Noosaville QLD 4566
'10"
of revetment wa
42.121m
Noosa Shire Council
13.078m
Locality - Noosaville
13293
Lot 610 on RP883864
9112
ll to centre
Site Area - 893m²
Zone - Low Density Residential
of jetty at revetm
wm Precinct - N/A
wm Overlays - Acid Sulphate Soils
proposed - Flood Hazard
- Landslide Hazard
11.598m
ent wall
masthead
jetty
canal
quay
144°18'30"
ent wall
320°22'35"
8783
Existing stone stairway
jetty at revetm
fh
elec
157°33'0"
l to centre of
mh telstra
elec
revetment wal
NSC sewer main
16058
Existing revetment wall
nt of
40.562m
16860 from fro
251°07
'10"
13.078m
Projecte
d bo undary
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
N o 1 3 G O D W I N P L A C E . P E L I C A N W A T E R S . Q L D . 4551 SDK SDK N3 MARK STEINERT NEW JETTY SITE PLAN 01 C 22.033 A3
RTH
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NO
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
No. 48 MASTHEAD QUAY, NOOSAVILLE Q 4566 SHEETS IN SET SCALE
C 11/08/22 SDK CONSTRUCTION ISSUE Lot 610 ON RP883864 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies