Cover Letter - Response RFI
existing services,
c) The existing garage is to be removed.
Response 1.2:
a) Concept Plans show a shared driveway with widths and clearances in accordance with
PSP6.
b) Plans show the proposed driveway extents 300mm past the proposed access handle,
c) Plans show a typical crossection with standard minimum clearance to new services and
verge width suitable for screening,
d) Plans show indicative house sites with car turning circles allowing cars to park and reverse
inside the property to exit in a forward direction.
Issue 2: The development of the site (driveways and future dwellings and associated hardstand
areas) will significantly increase stormwater runoff from the site. No detail on how the stormwater
runoff will be controlled, collected and discharged has been provided.
Information required:
1. Provide a preliminary stormwater management plan for the proposed development. The plan
must be prepared by a suitably person, demonstrate compliance with the Water Quality and
Drainage Code of The Noosa Plan 2020 and include but not to be limited to:
a) the discharge point within each lot;
b) the discharge point for the runoff from the driveway,
c) the connection to Council’s existing drainage system, and
d) any necessary inter-lot drainage easements.
Response 2.1: Concept Plans have the proposed interlot drainage stormwater management system
adjacent to the combined driveway which will collect runoff from each lot and
driveway then discharge to the existing gully pit via a stormwater pipe network. The
plan shows that the system will be inside an interlot drainage easement.
Issue 3: It appears that the existing overhead power connections to the subject site and the adjoining
property (No 11A) cross over the adjoining properties.
Information required:
1. Provide detail on the location of the existing overhead services and the proposed connections
for the new lots.
Response 3.1: The Concept Plans show how the overhead power supply can be changed to
provide underground power to all three lots.
If you require any additional information or clarification please not hesitate to contact us.
Yours faithfully,
Callaghan & Toth
A D Toth BE Environmental RPEQ (Env) (civil) MIEAust CPEng NPER CPESC
Director
Please view www.callaghanandtoth.com.au for all information on our company profile and terms and conditions for services
rendered
\\ct-server01\D\D\JOBS\CT Projects in progress\2217 9 Crystal St\Correspondence\Applications\Response NC RFI.docx