Council archive · source document
Attachment 3 Site Plans · OPW19/0177
Attached to the e-mail Operational Works Application OPW19-0177 34-36 Allambi Trc Noosa Heads.msg.
Plans and drawings: the text below has words only, no drawings.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
E B D
A B C WD.603 D WD.601 E WD.602 F G
6 125 2 600 1 400 2 390 5 130 6 530 2 650 3 350
POOL
WD.604
1 559
1 557
1.5m BACK SETBACK
1 2.0m BACK SETBACK 1
6.0m BACK SETBACK
RECREATION
COURT
below GYM/
6 085
6 085
POOL HOUSE
(below)
2 2
6.0m BACK SETBACK
3.0m BACK SETBACK
POOL
(below)
SPA DECK
8 535
8 535
SPA SPA
WD.604 (below) WD.604 (below)
RAFTER AWNING RAFTER AWNING RAFTER AWNING
(below) (below) (below)
3 3
ROOF ROOF
(below) POOL (below)
WD.604
5 550
5 550
H ROOF MASTER RETREAT ALFRESCO DECK
WD.702 line of wall under
(below)
under
(below) FG (below) ROOF
TER below (below)
under
G TER FG G
DP
WD.604 WD.604
line of wall under
1 130
o/h
under line of wall under
600
o/h
ROOF
4 GATE HOUSE ENTRY PATH
TER
(below) 600
4
DP 600
(below) (below) o/h
o/h
C MR1 5.0° MR1 5.0° C
WD.602 TER line of wall under WD.602
line of wall under
under
ENS FG FG
(below) BED 2
1 130 MASTER
TER TER
FG
o/h under FLUE to extend past roof by under
(below)
H BED 300mm within 3.60m of roof
6 300
6 300
6.0m BACK SETBACK
WD.702 to BCA 2019 part 3.10.7.3 under 5.0°
(below) flue
TER DP
5.0° 5.0° MR1
flashing around flue
MR1 MR1 DP
line of wall under 600
DP
o/h
600
o/h
valley gutter
<12º, refer eng. valley gutter
RUMPUS TER
y
PV
lle
<12º, refer eng.
va
under
(below)
va
5 5
lle
y
DP
flashing to parapet wall
ROOF BATH 600
F MASTER F
(below) o/h
2 470
2 470
WD.603 5.0° WD.603
(below) FG
ENTER
PW PV MR1 5.0° PV
flashing to parapet wall MR1 FG
(below)
line of wall under line of wall under
6 900
6
GAMES
6.0m BACK SETBACK
3.0m BACK SETBACK
o/h PV
DP
(below)
line of wall under MR1
5.0°
FG 5.0°
BED 3
A (below) A
WD.601 MR1
WD.601
TER
STUDY ROOF
under
(below)
6 680
6 680
MASTER (below)
DRIVEWAY CARPORT
ROBE
below below
(below) 5.0° MR1
FG
BED 4
DP (below) TER
MR1
600 under
flashing to parapet wall p'cpated to match roof sheet
5.0° MR1 5.0° o/h
900 FG line of wall under
7 o/h 900
o/h TER
DP
7
725
725
o/h
o/h
under
900
o/h
DP 2.0m BACK SETBACK DP
1.5m BACK SETBACK TER FG
3 055
3 055
DP DP
1 855 O.M.P.
FG TER under
under
1 500
OMP
line of wall under line of wall under
TER
WIN ATH
P
m)
SUN
7a
g(
in
Ris
Setting 5 pm
N Rising (6.30 am
ER H )
UMM PAT 6 125 2 600 1 400 2 390 5 130 6 530 2 650 3 350
S N
m
SU
0p
5 .3
E B D
A B C D E F G
i ng
tt
Se
WD.603 WD.601 WD.602
EXT. FINISHES LEGEND DP down pipe. MR1 metal roof - (no refers to type). WALL LEGEND GENERAL LEGEND FLOOR FINISH LEGEND BA3
issue
For Building Approval 3
issue / amendment
AC air conditioning EP epoxy flooring. NGL natural ground line. RC masonry blockwork
D04 denotes door number
FT1 FT2 31.07.19 ADG
Indicates extent of TILE
issue date drawn by
AS aluminium screen. FC fibre cement external cladding. PA pavers. W04 denotes window number
RC pool shell/off form concrete client
ASD aluminium sliding door FG fascia gutter. PB plasterboard RL 17.200 denotes finished floor level Deborah and Guy Woollard
C Indicates extent of CARPET
90MM ext. timber frame project
AL aluminium louvres, refer sched. FSC feature stone cladding. PEB pebblecrete pool coating + RL 17.700 denotes spot level Woollard Noosa Heads
location
70MM int. timber frame 50 step
ASD aluminium sliding door. FT1 internal floor tile (refer tile extents plan). PV photovoltic (solar) panel denotes change in level TF TD Indicates extent of TIMBER. 34-36 Allambi Tce Noosa Heads
AFW aluminium framed window. FT2 external floor tile (refer tile extents plan). PF compliant pool fencing brick ext. with timber frame denotes floor waste
ROOF PLAN
fw
denotes hard wired smoke GS DR Indicates extent CONCRETE
AT astro turf fill compacted fill. ref. engineer SAC side access concrete. Indicates extent of
alarm BCA 3.7.2 min Aboda Lee Foster • director Scott Falconer • director
chs shs structural posts - refer Design p - 0424 620 247 p - 0431 267 157
hwsa 300mm from wall
awn awning to detail. fire fireplace PW parapet wall. engineer.
Group e - [email protected] e - [email protected]
FINISH CODE LEGEND
the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
5° denotes direction of roof fall ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
BAL1 balustrade-(no refers to type). flue flue kit RC reinforced concrete. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
MR denotes roof material denotes additional 'extent' information
BLK masonry blockwork. GL gatic lid, ref. schedule REN render finish TD timber decking to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
SF structural footing, (xxxxxxxx)
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
brick feature brickwork HWS hot water service. RF rubber flooring. refer engineer. TS timber screening. DP denotes downpine denotes finish, refer 1000
XX
series drawings for schedule scale as shown @ A2 issue
chute laundry chute HR handrail. SAC service area concrete TER tapered exposed rafters. VER vergola. drawing no.
ROOF PLAN CUT site cut join joinery item SBJ silicone butt jointed glass. TF timber floor. VIN vinyl flooring. JXX
denotes item and number.
refer to Joiner for details
WD.204 BA3
SCALE 1:100 @ A2 DS driveway slab LPG LPG gas bottle. SP structural post, refer engineer. TIM timber cladding. WB weatherboard.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 3 Site Plans .pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file