EXT. FINISHES LEGEND 1 2 3 4 5 6 7
6 085 8 535 5 550 6 300 2 470 6 680
AC air conditioning.
DET-12 DET-15 DET-16 DET-15
AS aluminium screen. WD.705 WD.707 WD.707
parapet wall. p'coated DET-01
WD.707
WD.701
BOUNDARY
BOUNDARY
BOUNDARY
capping to match wall finish
AL aluminium louvres, refer sched.
FG PW MR1 BAL FG TER BAL FC MR1 AL flue WB TER FG FC brick NRG REN PW AFW brick PW FC TER FG AL MR1 AFW FC TER FG PW
AT astro turf.
ASD aluminium sliding door. 5.0°
5.0° 5.0°
AFW aluminium framed window.
awn awning to detail.
DP W43
BAL1 balustrade-(no refers to type). parapet wall to rake W26 W28
W27
BLK masonry blockwork.
with roof pitch
MASTER MASTER MASTER DP
DET-09
FG MR ASD ASD FG line of roof behind RETREAT AL ROBE STUDY
DP down pipe. WD.704
BED ENTRY painted hwd timber property pole
3°
EP epoxy flooring. DP
T.O.W R.L 39.510
TER 5.0°
FC fibre cement external cladding. DP +sprdr.
FFL 38.970 DP
SP brick brick SP brick FFL 38.970
FG fascia gutter. UPPER LEVEL TER DP UPPER LEVEL
10° 10°
FSC feature stone cladding. SP D01 T.O.W R.L 38.010
W12 W13 W14 W15 W16 W17 W18 W19 W20 W21 gate
FT1 internal floor tile (refer tile extents plan). T.O.W R.L 37.680 TFD DP D02 BLK REN
BLK SP
WB AL AL AL AL AL AL AL AL AL AL SP
dektite to DP
TER TER DET-08
ENTRY x2 capping to det. T.O.W R.L 37.200
FT2 external floor tile (refer tile extents plan). capping to det. DET-14
WD.704
OUTDOOR SITTING/SNUG FSC GARAGE AWN REN
AS
capping to det. DP WD.706 capping to det.
W22 BLK REN
T.O.W R.L 36.900
brick
T.O.W R.L 36.970
fill compacted fill. T.O.W R.L 36.740 GYM/ LOUNGE brick
DET-18
WD.707
T.O.W R.L 36.500
fire fireplace WB
POOL HOUSE WB
BLK REN ALFRESCO SP
AS AS
recessed meter box to energex req.
POOL T.O.W R.L 35.950
BLK REN BLK REN DS
flue kit BLK REN batter landscape as req'd
flue
T.O.W R.L 35.500 PF PF DECK capping to det. AS T.O.W R.L 36.970 DRIVEWAY
FFL 35.400 FFL 35.400
HWS hot water service. BLK REN BLK REN
MAIN LEVEL T.O.W R.L 33.900 MAIN LEVEL
HR handrail.
ARRIVAL BLK REN
T.O.W R.L 34.700 brick
join joinery item RECREATION brick POOL mailbox
BLK REN BLK REN DET-17 motorised entry gates. gate dock behind fixed
BLK REN
COURT (behind) WD.707 two seperate panels aluminium screen
LPG LPG gas bottle.
(behind) BLK REN
gate to det. intercom
MR1 metal roof - (no refers to type). BLK REN BLK REN DET-02
street signage WD.702
NGL natural ground line.
PA pavers.
PEB pebblecrete pool coating
PF compliant pool fencing
PW parapet wall.
RC reinforced concrete. WEST ELEVATION
RF rubber flooring. SCALE 1:100 @ A2
SAC side access concrete.
SBJ silicone butt jointed glass.
SP structural post, refer engineer.
SF structural footing, refer engineer.
TER tapered exposed rafters. refer det.
TF timber floor WEST ELEVATION
TIM timber cladding. 3D PERSPECTIVE
TS timber screening.
VER vergola.
WB weatherboard.
G F E D C B A
3 350 2 650 6 530 5 130 2 390 1 400 2 600 6 125
DET-15 DET-12 DET-12 DET-15
WD.707 WD.705 photovoltaic system location dektite flashing WD.705 WD.707
AWN MR1 FG TER WB BAL MR1 ASD FC MR1 FC TER SKY PV FG AS VER AL flue MR1 AL TER PW FC ASD MR1 BAL AWN WB TER FG
6M SETBACK
BOUNDARY
BOUNDARY
W45
5.0°
5.0°
5.0°
TOW to be 1800mm TER
above FGL to meet 1.8m
NCZ on pool side fence,
so not impacted by W37 W38 W39 W40 W42 W44
NORTH ELEVATION
adjoining lot. Fence not to BED 2 RUMPUS ENS MASTER
brick
3D PERSPECTIVE
exceed 2.0m above NGL DECK RETREAT MR1
where not covered by
AWN MR2
RAB relaxation DP +sprdr. DP +sprdr. 5.0° capping to det. DET-16 DET-02
5.0° DP +sprdr. WD.707 WD.702
FFL 38.970 TER
FFL 38.970
DP
UPPER LEVEL UPPER LEVEL
WB 10.0° 10.0° DP DP BA3 For Building Approval 3
DP partied h/d galv property pole issue issue / amendment
DET-14
DP
W10 ASD ASD DP
W11 WD.706 SP 31.07.19 ADG
DET-13 WB FC bulkhead CARPORT issue date drawn by
TER capping to det. client
DINING
WALL LEGEND GENERAL LEGEND
dektite to DP WD.706 capping to det. 2.0°
T.O.W R.L 36.960
DP
W25 DP dektite to DP SP
capping to det. ENTRY Deborah and Guy Woollard
flashing brick
FG
project
planting to det. flashing to det.
ALFRESCO ENTRY
alu. screen as compliant pool fence DP in column DET-05
OUTDOOR brick brick AS DP capping to det. RC masonry blockwork
D04 denotes door number Woollard Noosa Heads
brick WD.703 location
T.O.F R.L 36.000 WB TER AL MR1 FC WB FC FG
LOUNGE GATE W04 denotes window number 34-36 Allambi Tce Noosa Heads
DET-09 NGL+2
RC pool shell/off form concrete
capping to det.
RL 17.200 NORTH & WEST ELEVATION
PF HR
FFL 35.400 AS SAC PA
GYM/ WD.704
3
2 NGL+2 T.O.W R.L 35.300
FFL 35.400 denotes finished floor level
MAIN LEVEL MAIN LEVEL 90MM ext. timber frame
POOL HOUSE fence shown hidden for clarity 1
8 landing
DP brick
BLK REN NGL+2
+ RL 17.700 denotes spot level Aboda Lee Foster • director Scott Falconer • director
NGL pool tiled wet edge 7
6
T.O.W R.L 34.700 70MM int. timber frame 50 step
Design p - 0424 620 247
Group e - [email protected]
p - 0431 267 157
e - [email protected]
equipment BLK 5 STEPS 6
5
denotes change in level the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
3
BLK REN SAC POOL REN
4
3 RECREATION COURT STEPS 4
3 BLK REN brick BLK REN
sewer manhole
brick ext. with timber frame denotes floor waste
ABN 56 266 884 746
t/a aboda design group
Q. 4573. PO box 2449 Noosa Heads Q 4567
• BSA License -150580097 • www.aboda.com.au
2
RC tile NGL RC tile 2 2 planting T.O.W R.L 33.900 fw • This drawing is to be read in conjunction with engineers drawings & reports • Construction
1 R.170 AC NGL R.170 1 R.170 1
finished ground level denotes hard wired smoke to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
G.250 G.250 FGL R.L 33.490 G.250
REN
Indicates extent of
alarm BCA 3.7.2 min
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
NGL chs shs structural posts - refer site prior to commencement of any works • These drawings are not to be used for scaling.
300mm from wall
natural ground level fill 35m3 FILL NGL fill BLK engineer. hwsa scale as shown @ A2 issue
NORTH ELEVATION
SF SF NGL
natural ground level 5° denotes direction of roof fall drawing no.
SCALE 1:100 @ A2 SF SF structural footing,
TD timber See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 3 Site Plans .pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.