Bushfire Hazard Assessment & Management Plan v2 - 30 Pottery St Pomona 2021
Bushfire Hazard Assessment & Management Plan v2 NCES REF: J000864 Lot 496 on MCH591 – 30 Pottery St, Pomona society will not accept this risk and measures are to be put in place to reduce risks to at least a tolerable level. Assessment Benchmark 4 of the SPP Bushfire 2019 references radiant heat flux exposure of <29kW/m² on any part of the building as generating an Acceptable to Tolerable level of risk. AS/NZS ISO 31000:2018 defines ‘Likelihood’ as the chance that something might happen. Likelihood can be defined, determined, or measured objectively or subjectively and can be expressed either qualitatively or quantitatively (using mathematics ). The following ‘likelihood’ categories for the probability of the assessed bushfire attack mechanisms impacting the assessment area have been adopted within this assessment: • Likely - Will probably occur • Unlikely - Could occur but doubtful The determination of whether a bushfire event is likely or unlikely to occur (i.e. impact the site) has been based on the relative position of hazardous vegetation to the site. Hazardous vegetation located upwind of the site under typical south-east Queensland (SEQ) seasonal fire winds from the north to north-west to west to south-west are deemed to be exposed to a ‘likely’ probability of impact. Hazardous vegetation located downwind of the site under typical SEQ seasonal fire winds are deemed to be exposed to an ‘unlikely’ probability of impact. 4.2 Risk from Identified Hazardous Vegetation The Plan of Development depicts the building envelope within proposed Lot 8 (Stage 1) and Lots 9 and 10 (Stage 2) as immediately flanking the identified hazardous vegetation to be retained within the west of the site. The likelihood of a fire approaching from the west is considered likely, given dominant regional fire weather winds are derived from the north-west to south-west. The degree of separation offered to the adjoining vegetation is the primary driver of the assigned level of risk and was determined with consideration to the Flamesol modelling output presented in Section 3.3. In the absence of an appropriate separation buffer to the adjacent vegetation, and implementation of relevant AS3959-2018 construction standards, the future dwellings on the site could be exposed to direct flame, severe radiant heat and ember attack during the modelled bushfire conditions resulting in total structure loss. The Plan of Development provides a dedicated Asset Protection Zone setback of 19m to VHC 9.1 open Eucalypt forest to the west of the Lot 8 - 10 building envelopes and includes a trafficable firebreak. >17.2m separation is the maximum separation required to ensure the proposed building envelopes on Lots 8-10 are exposed to <29kW/m² radiant heat flux as per the Flamesol modelling presented herein. The extent of proposed separation therefore facilitates an acceptable risk of radiant heat impact. Lots 1 – 6 are separated from the western VHC 9.1 by a minimum of approximately 50m including partial shielding offered by the future dwellings on Lots 8 -10. The likely risk of a fire front approach from the west would therefore expose the buildings within Lots 1 – 6 to an acceptable risk of radiant heat impact as they too are separated by >17.2m from the forest hazard. © 2021 20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.