AMENDMENT SCHEDULE
ISS DATE DESCRIPTION BY
A 30/06/23 RESPONSE TO 2ND RFI ZT
8 METRE BUILDING LIMIT
8 METRE BUILDING LIMIT 8 METRE BUILDING LIMIT
1464
1464
1464
PITCHING HEIGHT PITCHING HEIGHT PITCHING HEIGHT
FC MWC SS
FC
FC
2500
2500
2500
MWC
FC
AB AB FC MWC AB
AB AB
6964
6964
6964
FC
AB BAL1
LEVEL 1 LEVEL 1 LEVEL 1
SS
MWC FC
AB
3000
3000
3000
BAL1
MWC FC AB AB AB FC FC MWC AB
AB AB
BAL1
GROUND FLOOR GROUND FLOOR GROUND FLOOR
RWT
CABIN 8 & 9 ELEVATION A
1 CABIN 8 & 9 ELEVATION B
1 : 100 2 CABIN 8 & 9 ELEVATION C
1 : 100 3
1 : 100
8 METRE BUILDING LIMIT
1464
MRS
PITCHING HEIGHT
FC
33.00°
2500
MRS
AB
8 METRE BUILDING LIMIT AB
6964
LEVEL 1
AB FC
RL 12.414
3000
BAL1
AB
AB
5.00°
MRS
1213 GROUND FLOOR
1294
RWT
PITCHING HEIGHT
SS
CABIN 8 & 9 ELEVATION D
LIVING DINING KITCHEN
MRS
CABIN 9 4
2500
1 : 100
6794
LEVEL 1
SS
AB CABIN 8
3000
LIVING DINING KITCHEN
RL 5.450 BAL2
GROUND FLOOR
TOOWOOMBA | BRISBANE | MOOLOOLABA
www.aspectapm.net
ABN 96 071 786 948 ACN 071 786 948
RWT BOAQ 4487
EXISTING GROUND LINE
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
CABIN 8 & 9 SECTION CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
5 DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
1 : 50 PERMISSION OF ASPECT .
PROJECT
RACV NOOSA RESORT - ECO
RESORT
FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
CONCEPT DESIGN
@
LEGEND 142 NOOSA DRIVE, NOOSA HEADS
AB ALUMINIUM TIMBER LOOK BATTENS QLD 4567
BAL1 BALUSTRADE, TYPE 1 DRAWING TITLE
BAL2 BALUSTRADE, TYPE 2
FC FIBRE CEMENT SHEETING
MRS METAL ROOF SHEET
MWC METAL WALL CLADDING
RWT RAIN WATER TANK CABIN 8 & 9 ELEVATIONS
SS SUNSHADE DATE SCALE @ A1 DRAWN CHECKED
30/06/23 As indicated ZT TB
DRAWING No. ISSUE
21-0910_ AA30-05 A