MCU22/0118 – DEVELOPMENT APPLICATION FOR A MATERIAL CHANGE OF USE – SHORT-TERM ACCOMMODATION AT 94 & 142 NOOSA DR, NOOSA HEADS (Referred from Planning & Environment Committee dated 7 November 2023 - Item 5.1) · ATTACHMENT 2 – PROPOSAL PLANS
Plans and drawings: the text below has words only, no drawings.
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
IMPORTANT:
ALL DRAWINGS MUST BE READ IN CONJUNCTION WITH
THE GENERAL NOTES SHEET
AMENDMENT SCHEDULE
5 5
A30-06 A30-06
ISS DATE DESCRIPTION BY
A 04/10/22 CABIN ELEVATIONS ZT
B 24/10/22 DA RFI ZT
C 28/10/22 DA RFI ZT
D 8/11/22 DA RFI ZT
E 30/06/23 RESPONSE TO 2ND RFI ZT
8 METRE BUILDING LIMIT
8 METRE BUILDING LIMIT
MRS
MRS
8 METRE BUILDING LIMIT
MRS
1596
1596
1596
MRS
FC MRS
PITCHING HEIGHT FC PITCHING HEIGHT PITCHING HEIGHT MRS
SS
FC AB
2500
2500
2500
MWC MWC MWC FC AB
7096
7096
7096
BAL1 BAL1
LEVEL 1 AB
LEVEL 1 LEVEL 1
SS
FC MWC
AB AB
AB
3000
3000
3000
MWC FC AB
MWC
AB
BAL1 BAL1
GROUND FLOOR GROUND FLOOR GROUND FLOOR
RWT
5
5
A30-06
A30-06
CABIN 10 & 11 ELEVATION A CABIN 10 & 11 ELEVATION B CABIN 10 & 11 ELEVATION C
1 2 3
1 : 100 1 : 100 1 : 100
MRS 8 METRE BUILDING LIMIT
1596
PITCHING HEIGHT FC
8 METRE BUILDING LIMIT
2500
AB AB MWC AB
7096
BAL1
MRS RL 12.296
5.00° LEVEL 1
1230
1596
3000
AB AB MWC AB
AB
BAL1
PITCHING HEIGHT GROUND FLOOR
RWT
2500
LIVING DINING KITCHEN ENTRY CABIN 10
AB
CABIN 10 & 11 ELEVATION D
7096
LEVEL 1 4
1 : 100
AB
3000
AB LIVING DINING KITCHEN ENTRY CABIN 11 TOOWOOMBA | BRISBANE | MOOLOOLABA
www.aspectapm.net
ABN 96 071 786 948 ACN 071 786 948
BOAQ 4487
GROUND FLOOR
BUILDING DESIGNERS
ASSOCIATION
GENERAL NOTES
RWT THIS PLAN HAS BEEN PREPARED IN ACCORDANCE WITH ALL
RELEVANT BUILDING CODES AND STANDARDS. NO AMENDMENTS
SHALL BE MADE WITHOUT THE APPROVAL FROM ASPECT AND/OR
RELEVANT LOCAL AUTHORITY.THESE DRAWINGS ARE SUPPLIED ON
THE CONDITION THAT, IN THE EVENT OF ERROR, ASPECTS' LIABILITY
IS LIMITED ONLY TO THE COST OF AMENDING THESE DRAWINGS.
CONTRACTORS ARE TO VERIFY ALL DIMENSIONS ON SITE BEFORE
COMMENCING ANY WORK OR PRODUCING SHOP DRAWINGS. THESE
DRAWINGS ARE PROTECTED BY THE LAWS OF COPYRIGHT AND MAY
NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN
PERMISSION OF ASPECT .
PROJECT
RACV NOOSA RESORT - ECO
RESORT
FOR
ROYAL AUTOMOBILE CLUB OF
VICTORIA
CONCEPT DESIGN
CABIN 10 & 11 SECTION
@
142 NOOSA DRIVE, NOOSA HEADS
5 LEGEND
QLD 4567
1 : 50 AB ALUMINIUM TIMBER LOOK BATTENS DRAWING TITLE
BAL1 BALUSTRADE, TYPE 1
FC FIBRE CEMENT SHEETING
MRS METAL ROOF SHEET
MWC METAL WALL CLADDING
RWT RAIN WATER TANK CABIN 10 & 11 ELEVATIONS
SS SUNSHADE DATE SCALE @ A1 DRAWN CHECKED
30/06/23 As indicated ZT TB
DRAWING No. ISSUE
21-0910_ AA30-06 E