MCU22-0051_Change Representations_v1.4_041223 · MCU22/0051

of 14

Text shows just the words. Original shows the document exactly as it was published.

Our ref: 102995-10

1.    Building height – operational and structural requirements

The proposed building height is based on Bunnings’ operational and workplace health and safety arrangements
(forklifts operate internally and require certain clearance). The proposed floor to ceiling heights are based on:
•     Bunning’s standard height for a trade centre is 7.75 metres from ground level to the top of parapet walls (i.e.
      where car parking is provided beside or in front at grade), however in this instance car parking is proposed at
      undercroft level.
•     Undercroft parking, including structure (suspended slab) and clearance for services, equates to approximately
      4.4 metres.
•     The typical 7.75 metre typical trade height (in this instance, the upper level) is needed in order to provide
      internal clearance for:
      –      Internal racking height of 4.4 metres.
      –      1200mm pallets that are placed on top of the racking.
      –      A clearance zone required for OH&S reasons (need clearance above the pallets to allow forklifts to lift the
             pallets on and off the top racks).
      –      Roof structure (rafters, purlins, sheeting and roof pitch)
Reduction of the height of any of elements will compromise the ability for the trade centre to function as intended
and to provide the services intended to local trades customers and construction industry. It will also compromise
workplace health and safety arrangements that require clearances for forklift operations and pallet storage. In
conditioning a lesser height, the development will not be able to function, denying Noosa this trade resource and
services that are needed to support the local construction industry.

2.    Building height – unreasonable to rely on the Maroochydore trade centre as a precedent

During Council’s General Meeting, reference was made to the Bunnings trade centre at 547 Maroochydore Road,
Kunda Park where the building sits at a height of below 10 metres. During discussions, the building was cited as a
precedent, justifying a 10 metre height limit for this development with mention that it was ‘down the road’ from the
Noosaville site.
We submit that using the Maroochydore trade centre as a basis to inform building height on the Noosaville trade
centre is invalid due to the following:
•     The Maroochydore trade centre is contained in an old building historically used for industrial or rural activities.
      It has been re-purposed in more recent years for the Trade Centre. The building was not purpose designed for
      Bunnings.
•     The Maroochydore trade centre is located on a much larger landholding, where car parking can be provided in
      the open air, beside the building. The Maroochydore trade centre does not require an undercroft car parking
      area.
•     The Maroochydore trade centre is approximately 40km and a 30-minute drive from the Noosaville site. This is
      a significant distance and does not represent built form of the ‘surrounding area’ of Noosaville, let alone the
      industrial precinct along Gateway Drive.
•     The Maroochydore trade centre is located within the Sunshine Coast Regional Council area. The building
      itself is historical (a longstanding building predating the current planning scheme). Development that occurred
      under Sunshine Coast Regional Council / former Maroochy Shire planning schemes should not be relied upon
      to determine outcomes for the Noosa Shire.
•     Council did not consider the differences in site conditions between the Maroochydore and Noosaville sites.
      The Maroochydore trade centre occupied an existing building which had car parking on ground level. Built
      form components such as height, parking and access did not need to be addressed as it was all existing. The
      Noosaville site is required to raise the building to respond to both topographic constraints and provide
      sufficient car parking, aspects the Maroochydore site did not need to address.
Accordingly, we request Council to disregard the Maroochydore trade centre when reviewing the proposed
amendment to Conditions 3 and 13.


RPS AAP Consulting Pty Ltd. Registered in Australia No. 97 117 883 173
rpsgroup.com                                                                                                Page 3

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

MCU22-0051_Change Representations_v1.4_041223.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.