4 Pines Noosa                                                                                           Reference: #1869d1-A
81 Noosa Drive, Noosa Heads QLD                                                                        Date: 20 February 2025
Entertainment Noise Assessment

 The distance input was calculated using Queensland Government
 imagery, whereby the shortest distance between the closest outdoor
 area to each applicable RAP was calculated.

 The predicted sound pressure levels were converted to octave band
 spectra, utilising the ‘Raised’ voice spectra detailed in the AAAC
 Licensed Premises Guideline (V2).

 Patron noise levels were predicted at the CEMLs, RPLs and RAP
 measurement locations. The cumulative amplified entertainment and
 patron noise intrusive level at these locations was then calculated using
 decibel log addition. The results of the above equation were input into the
 Guideline 51 calculations (refer to Appendix B – Calculation Summaries)
 to provide an intrusive noise level due to amplified entertainment and
 patron noise.


 3.9 Instrumentation
 Table 5 below presents a list of noise survey instrumentation used for this                           G51 Check Item 45 ☐

 noise assessment.
                                           Table 5. Noise survey instrumentation
 Model                       Description                   Manufacturer           Serial #              NATA calibration date
 Nor139                      Sound level meter             Norsonic               1393046               09/10/2023
 CAL200                      Field calibrator              Larson Davis           23157                 10/07/2024




 3.9.1 Field calibration levels
 The noise logger was calibrated with a CAL200 calibrator at a sound                                   G51 Check Item 46 ☐

 pressure level of 94.0dBA at 1kHz before and after each set of
 measurements. Calibration drift was found to be within ±0.3dB and
 therefore considered acceptable. Provided below in Table 6 are the field
 calibration dates, times and levels.


                                                Table 6. Field calibration levels
 Date of field calibration     Time of field calibration      Sound level meter     Field calibrator      Field calibration
                                                                                                          levels, dBA
 23/01/2025                    8:28am                         Nor139                CAL200                94.0
                               10:23am                        Nor139                CAL200                94.0
 17/02/2025                    9:50pm                         Nor139                CAL200                94.0
                               10:40pm                        Nor139                CAL200                94.0
 17/02/2025                    12:56am                        Nor139                CAL200                94.0
                               1:40am                         Nor139                CAL200                94.0




Live It Acoustics | Controlled Document v1.0                                                                           Page 21
Log in to download the original file

Reference Documents - MCU24-0115 [As Published].pdf · 4.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.