Original source · versioned page text
Reference Documents - MCU24-0115 [As Published]
4 Pines Noosa Reference: #1869d1-A 81 Noosa Drive, Noosa Heads QLD Date: 20 February 2025 Entertainment Noise Assessment 4 Results and Discussion 4.1 Summary of findings No major acoustical issues were identified during testing. G51 Check Item 47 ☐ The calculated maximum allowable noise level associated with amplified entertainment (with the façade fully closed and entry only via the sound lock) is expected to be sufficient to host amplified entertainment at a “nightclub” level, during all approved operating times. With the façade fully open, the calculated maximum allowable noise level associated with amplified entertainment is expected to be sufficient for general background music during all approved operating times. Due to the amount of urban activity and extraneous noise from traffic, pedestrians etc. in the vicinity of the subject site, it may be difficult for the licensee to monitor compliance at the CEMLs. It is recommended that compliance be monitored primarily at the SPLA. 4.2 Recommended noise limits 4.2.1 Close External Monitoring Locations Presented below are the summarised noise limits at the CEMLs, based upon the calculations provided in Appendix B – Calculation Summaries. The limits presented indicate the calculated level limit for the venue operating configuration as described in Section 3.7. Measurements should be made at the CEML in either dBA (before 10:00PM) or dBC (after 10:00PM) using ‘Fast’ time weighting. Table 7. Calculated noise limits at the CEMLs Venue Configuration Close external Limiting Maximum noise limit at CEML monitoring location representative (CEML) [3] affected premises Before 6:00PM, Before After 10:00PM, dBA [1] 10:00PM, dBA dBC [2] [1] [a] Façade open CEML-1 RAP.3 88 -- -- RAP.3 -- 65 -- RAP.3 -- -- 65 CEML-2 RAP.6 68 n/a n/a Façade closed [b] CEML-1 RAP.1 n/a 61 71 CEML-2 -- n/a n/a n/a G51 Check Item 48 ☐ [a] Test configuration is shown in Figure 9 and described in detail in Section 3.7.1. [b] Test configuration is shown in Figure 10 and described in detail in Section 3.7.1. [1] Measured in dBA using a ‘Fast’ Time Weighting. [2] Measured in dBC or dBZ using a ‘Fast’ Time Weighting. [3] CEML locations are marked in Figure 6 and photos provided in Appendix D – Detailed Measurement Locations. Live It Acoustics | Controlled Document v1.0 Page 22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.