26281_OW1 to SW1_Issue 9 · OPW19/0278.01
Attached to the e-mail Operational Works Minor Change Application OPW19/0278.01.
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 .5
1. 1.4
48
54
1.
1.
1.
1
1
1. 1
PP PP
59
1. .55
54
56
50
54
1
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
64
1.
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10
2
4 2 STOREY
7
1. BRICK UNITS
35.46
2 GTP395
59
67
630m²
1.
1.
6.09
72
1.73
3
66
1.
77
1.
1.
1.
742m²
SHED
35.46
68
GTP156216
1.
18.36
DECK
IO
MH
LL: 1.53
CP
49
IL: 0.52
1.
65
50
47
1.
1.
1.
14.83 20.92
60
1.
2 STOREY 6 GTP671
SINGLE STOREY
4 RP72986 BLOCK & H'PLANK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
LOTS 2 & 3 ON RP 78252
Level Datum AHD
Ny Level Origin PM 56277, RL 1.635m
EXISTING STRUCTURE /DWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER/CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR 10
COMMENCING WORKS.
Y Ground / U/)
pad Tevel
Vie UNSTABLE i; ae THIS FOOTING WITHOUT
| |
Va
THIS FOOTING IS FOUNDED | ee PIERS 1S FOUNDED
X ABOVE CRITICAL DEPTH
BELOW CRIICAL DEP oR UNE AND S UNSTABLE
LINE AND IS STABLE. STABLE COS
|
| LINE OF PROPOSED TRENCH
—— EXCAVATION. OR EXISTING
SERVICES TRENCH
PIERS OR UNDERPINNING FOUNDED \ 1B
BELOW THE CRITICAL DEPTH LINE NI
WOULD BE NEEDED 10 SUPPORT N
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE.
N\
‘N
Horizontal 30 Dedfess\
OTE:
CRITICAL DEPTH LINE. TH DETAL ALSO APPLIES TO EXISTNG FOUNDATIONS
ON NEIGHBOURING PROPERTIES. SHEET PILING MUST
BE INSTALLED WHERE EXISTING FOOTINGS WILL BE
FOUNDED ABOVE ANY EXCAVATION CRITICAL DEPTH
LINE
_—
RL 1.4 APPROX.
9350 CONCRETE SEWER PROTECTION
PIERS FOUNDED 300mm BELOW THE
HCB INVERT LEVELS AS SHOWN.
www.dialbeforeyoudig.com.au
SAY DIAL 1100
“Wy BEFORE YOU DIG
4/N12/FULL HT
EXISTING DRIVEWAY
(10 BE MODIFIED TO KERB)
PROVIDE ADDTIONAL 3/N16
BARS x 4500(L) IN TOP OF
RETAINING WALL FOOTING FOR
SEWER PROTECTION.
4 _ KERB ®
=
S
Hs
MAINTAIN MIN. 1.2myDISTANCE
BETWEEN STRUCTURES AND
SEWER LINE AS PER QDC
REQUIREMENTS.
co I
T we 2 20.02 &
POOL
UNIT 1
FFL 2.7
RiPso BOUNDARY
PIERING TO REYAINING WALL
ADJ NEW SEWER BRANCH /
/ LS
UNIT 2
D BOUNDARY
\\
_——
FFL 2.70
5 NUIGNE
SS
REFER SECTION a Y r
il @ (
2
630m?
( [RN
\
\ SP
é
LSS
SHED
UNIT 4 J 3
FFL 2.70
norsk REM
UNIT 3
// FFL 2.70
Tr
DECK
POOL
14.83
| go
COMMON
2ST
N- BRIC
GTP395
GTP1pt
R.P. BOUNDARYS2: 40
4
SINGLE STOREY
SITE PLAN — SEWER PROTECTION PLAN
Scale 1: 100
BLOCK RETAINING WALL
TO DESIGN AND DETAIL
BY THIS FIRM.
“wv a ee ee
1.2m MIN. 1.2m MIN.
0.3m
MIN
EXISTING UNITYWATER SEWER MAIN.
BUILDER TO CONFRIM PROIR TO
CONSTRUCTION AND ADJUST TO
WHAT IS ENCOUNTERED ON SITE.
(OR \HCB PROTECTION - BLOCK WALL
(7 TYPICAL SECTION
BLOCK RETAINING WALL
TO DESIGN AND DETAIL
BY THIS FIRM.
RL 1.4 APPROX. ae
EXISTING SEWER LINE.
2 STOREY
BLOCK & H'PLANK
RP72986
EXISTING HCB DECOMISSIONED
RL 2.3 APPROX. PAVEMENT
GTF
| DIAGRAM
FOOTING AND SLAB TO
DESIGN ANO\ DETAIL BY
THIS FIRM.
RETAINING
y RP. BOUNDARY
1.0m MAX.
—w Oo
(cONROLED FL
ON |
9350 CONCRETE SEWER PROTECTION
PIERS FOUNDED 300mm BELOW THE
Ly SEWER INVERT LEVELS AS SHOWN.
1.2m MIN. 4/N12/FULL HT
0.3m
MIN.
(BI \ REAR SEWER PROTECTION - BLOCK WALL
\/ TYPICAL SECTION
EXISTING UNITYWATER 1508 SEWER
MAIN. BUILDER TO CONFIRM PRIOR
WHAT IS ENCOUNTERED ON SITE.
EXISTING STRUCTURES IN NEIGBOURING
PROPERTIES TO BE PROTECTED AGAINST
6 UNDERMINING DURING TRENCHING .
WORKS, REFER CRITICAL DEPTH LINE FH.
TO CONSTRUCTION AND ADJUST TO
LEGEND
INDICATES EXISTING SURFACE
48.0 CONTOUR AND LEVEL TO AHD.
——— ————_ INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES PROPOSED SEWER LINE
——— w——— __INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR TO WORKS
——_1 ——_ INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR TO WORKS
——— sw————_ INDICATES STORMWATER DRAIN
PROPOSED AS NOTED MIN 1 IN
100 FALL UNLESS NOTED
OTHERWISE
INDICATES STORMWATER DRAIN
EXISTING AS NOTED MIN 1 IN 100
FALL UNLESS NOTED OTHERWISE
SW/EX
EX.
EX.
RC.
EX.
EX.
TIMBER RETAINING WALL
TO DESIGN AND DETAIL
BY THIS FIRM.
R.P. BOUNDARY
RL 2.40 APPROX. DESIGN FFL
“
eee
RL 1.7 APPROX. Oo SRE
DEEPEN POST PAD FOOTINGS AS
SHOWN TO PROTECT SEWER PROVIDE
4/N12 BARS FULL HT WHERE WALL
POST NOT EXTENDED TO BASE OF
FOOTING
1.2m MIN.
0.3m
MIN
(BD REAR SEWER PROTECTION - TIMBER WALL
(TYPICAL SECTION
fany-——1_?——)_?'m1:100 © At
1:200 @ A3
SWMH
E.0.B.
K&Cc
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED 10 THE ENGINEER
IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE
THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED
CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY
FINISHED TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB
DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY
2ND MESH WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE
EDGE OF CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED
PRIOR TO WORK COMMENCING
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER TO
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION WITHIN. THE
ALLOTMENT BOUNDARY TO BE IN ACCORDANCE WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, AFTER OBTAINING ALL NECESSARY PERMITS AND
APPROVALS.
4, THE CONTRACTOR IS TO CONFIRM THE POSITION OF ALL EXISTING
SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS PRIOR TO
THE COMMENCING OF WORK.
5, STORMWATER DRAINAGE PIPES SHALL BE CLASS SH UPVC OR CLASS
2 R.CP RUBBER RING JOINTED PIPE AS NOTED LAID AT A MINIMUM
GRADE OF 1 IN 100 U.N.0. JOINS ARE TO BE CONSTRUCTED IN
ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS.
6. SEWERS 100MM DIAM. UPVC U.N.O. AND LAID AT A MINIMUM GRADE
OF 1 IN 60.
7. WATER SUPPLY PIPEWORK BELOW GROUND IS TO BE ;
63MM DIAM. OR LESS - HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO BE
TYPE B COPPER.
9. WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL
JOINS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB.
10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE INSTALLED IN
ACCORDANCE WITH AS2419.1. HOSE REELS ARE TO BE INSTALLED IN
ACCORDANCE WITH AS2441,
11. CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS SITUATED IN
VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED WITH EITHER
BRASS OR CAST-IRON COVERS.
12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED
CONCRETE PATH BOXES.
13. ALL WASTE PIPES AND WATER SERVICES PENETRATING SLABS TO BE
WRAPPED IN AN APPROVED FLEXIBLE JOINT JOINT WRAPPING.
14, THE TERM ’SERVICE’ REFERS TO THE MINIMUM INTERNAL PIPE
DIAMETER UNLESS NOTED OTHERWISE,
KEY
SWPT EXISTING STORMWATER MANHOLE /PIT
SCP EXISTING SEWER CONNECTION POINT
HW. — REINFORCED CONCRETE HEADWALL
SMH — EXISTING SEWER MANHOLE
SWMH = EXISTING STORMWATER MANHOLE
NEW 1050 STORMWATER MANHOLE
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL POWER POLE
EXISTING KERBING
STOP VALVE
Cc RETAINING WALL AMENDED 11.02.20
B AMENDED FOR NEW ARCHITECTURALS | 06.09.18
A SEWER/BRANCH EASEMENT RELOCATED] 08.11.17.
Revision
Iss
Description Date
"FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
C) Ste
Title:
OPERATIONAL WORKS:
SEWER PROTECTION DETAILS
Lots 2 & 3 RP/8252
Elizabeth St, NOOSAVILLE
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
‘ABN 40 098 481 899,
DEBUILD T/A
Date: Nov 16 Drawn CSK
; Checked: Drg No. Rev
Fide NV |26281-OW4 | C.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
26281_OW1 to SW1_Issue 9.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.