Council archive · source document
26281_OW1 to SW1_Issue 9 · OPW19/0278.01
Attached to the e-mail Operational Works Minor Change Application OPW19/0278.01.
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 .5
1. 1.4
48
54
1.
1.
1.
1
1
1. 1
PP PP
59
1. .55
54
56
50
54
1
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
4
1.
6
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10
2
4 2 STOREY
7
1. BRICK UNITS
35.46
2 GTP395
9
67
5
630m²
1.
1.
6.09
72
3
66
1.
77
1.
1.
742m²
SHED
35.46
68
GTP156216
1.
18.36
DECK
IO
MH
LL: 1.53
CP
49
IL: 0.52
1.
65
0
47
5
1.
1.
1.
14.83 20.92
60
1.
2 STOREY 6 GTP671
SINGLE STOREY
4 RP72986 BLOCK & H'PLANK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
LOTS 2 & 3 ON RP 78252
Level Datum AHD
Ny Level Origin PM 56277, RL 1.635m
www.dialbeforeyoudig.com.au
SAY DIAL 1100
“Wy BEFORE YOU DIG
PROPOSED LOT 2 & 3 INSTALL DOMESTIC 25 Diam
BRANCH CONNECTION AND METERS FROM WATER MAIN
IN ACCORDANCE WITH UNITYWATER SPECIFICATIONS &
DETAILS. UNITYWATER APPROVAL TO BE OBTAINED
ALL WORKS BY UNITYWATER AT DEVELOPERS COST.
REFER TO HYDRAULIC CONSULTANTS DRAWINGS FOR
METER REQUIREMENTS.
NEW 256 DIAMETER
BRANCHES FROM WATER
MAIN
BM: NAIL IN KERB
= = % Ao A _KERB J ® RL A
NPP Ke N SX PRO -
E E = se QE EY > ¢ E — E 27 at
‘ x z
Ww =. w w Ww Ny 2 7 w—4 w 7 —_w w w
—_ ¥ a - EX. WW Ud pt _.
lr 20.92 ~ Le eo [<2 | 20.92 e
| | ~
POL \ Pod!
INTERNAL WATER SUPPLY, \ COMMON
RETICULATION BY HYDRAULICS ~
CONSULTANT. TYPICAL. >! & fl
& 7 \ sl
e\ Ly :
8252 3 Y 3
— UNIT 1 oY 13
= | FFL 2.70 4 2
I
\z UNIT 2 , 2st
| 4 \z FFL 2.70 \’ BRIC
/ \ /) g
( 8
\ © * 2 “ee L GTP395
Le © Bk
- 3 x 630m? S — - — - —
> eS | \g ww 3 “
\~* 742m?
SHED LO
Io
UNIT 4 | ID
2
FFL 2.70 | >
/| =
0, & 7 i UNIT 3 5 GTP1pt
© | FFL 2.70 a
o a
© a
~ 4 Oe
5
a
—_ 10) |
c | CP
£ I ao ——— = _ >
e 1488 — RP? BOUNDARY
SINGLE STOREY
SITE PLAN — WATER SUPPLY
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
4
RP72986
2 STOREY
BLOCK & H'PLANK
6 GTF
EXISTING PROPERTY
BRANCHES & METERS TO BE
CAPPED OFF & REMOVED.
TYPICAL.
sw
SW/EX
LEGEND
INDICATES EXISTING SURFACE
CONTOUR AND LEVEL TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES PROPOSED FINISHED
SURFACE LEVELS
INDICATES DIRECTION OF FALL
TO FINISHED SURFACES.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES PROPOSED SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN
PROPOSED AS NOTED MIN 1 IN
100 FALL UNLESS NOTED
OTHERWISE
INDICATES STORMWATER DRAIN
EXISTING AS NOTED MIN 1 IN 100
FALL UNLESS NOTED OTHERWISE
fany-——1_?——)_?'m1:100 © At
1:200 @ A3
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED 10 THE ENGINEER
IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE
THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED
CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY TO BE 125mm THK. EXCLUDING ANY
FINISHED TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB
DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WITH EVERY
2ND MESH WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE
EDGE OF CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED
PRIOR TO WORK COMMENCING
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER TO
ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION WITHIN. THE
ALLOTMENT BOUNDARY TO BE IN ACCORDANCE WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AUTHORITIES
HAVING JURISDICTION, AFTER OBTAINING ALL NECESSARY PERMITS AND
APPROVALS.
4, THE CONTRACTOR IS TO CONFIRM THE POSITION OF ALL EXISTING
SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS PRIOR TO
THE COMMENCING OF WORK.
5, STORMWATER DRAINAGE PIPES SHALL BE CLASS SH UPVC OR CLASS
2 R.CP RUBBER RING JOINTED PIPE AS NOTED LAID AT A MINIMUM
GRADE OF 1 IN 100 U.N.0. JOINS ARE TO BE CONSTRUCTED IN
ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS.
6. SEWERS 100MM DIAM. UPVC U.N.O. AND LAID AT A MINIMUM GRADE
OF 1 IN 60.
7. WATER SUPPLY PIPEWORK BELOW GROUND IS TO BE ;
63MM DIAM. OR LESS - HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO BE
TYPE B COPPER.
9. WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL
JOINS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB.
10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE INSTALLED IN
ACCORDANCE WITH AS2419.1. HOSE REELS ARE TO BE INSTALLED IN
ACCORDANCE WITH AS2441,
11. CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS SITUATED IN
VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED WITH EITHER
BRASS OR CAST-IRON COVERS.
12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED
CONCRETE PATH BOXES.
13. ALL WASTE PIPES AND WATER SERVICES PENETRATING SLABS TO BE
WRAPPED IN AN APPROVED FLEXIBLE JOINT JOINT WRAPPING.
14, THE TERM ’SERVICE’ REFERS TO THE MINIMUM INTERNAL PIPE
DIAMETER UNLESS NOTED OTHERWISE,
KEY
EX. SWPT EXISTING STORMWATER MANHOLE /PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. — REINFORCED CONCRETE HEADWALL
EX. SMH EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE
EX. WM EXISTING WATER METER
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
N.S.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
SV STOP VALVE
Cc. AMENDED FOR NEW ARCHITECTURALS | 09.04.17
B. SEWER/BRANCH EASEMENT RELOCATED] 08.11.17.
A. UNITY WATER REVISIONS TO WATER. 23.08.17.
Revision Description Date
Iss
"FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
az Unit 1/11 Project Ave,
Noosa Heads
SC G Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
ABN 40098 481 699
DEBUILD T/A
Title:
OPERATIONAL WORKS:
WATER SUPPLY
Project
Lots 2 & 3 RP/8252
Elizabeth St, NOOSAVILLE
Drawn
Pate: Nov 16 CSK
Checked: Drg No.
was 96 981-OWS C.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.