Original source · versioned page text
Bushfire Hazard Management Plan v3 - 27 Wilgee Ct Cooroy
Plans and drawings: the text below has words only, no drawings.
Bushfire Hazard Management Plan v3 NCES REF: J000662
Lot 101 on SP142407, Lot 140 on MCH978, Lot 3 on RP137375,
Lot 2 on RP852009 and Lot 8 on RP160703 - 27 Wilgee Court, Cooroy
Table 3 – Table 13.9 Bushfire Hazard Areas – Natural Hazards Overlay Code Noosa Plan 2006
SPECIFIC OUTCOMES PROBABLE SOLUTIONS PROPOSED SOLUTION
13.39 Reconfiguration of a Lot
General
O10 The safety of people and property are S10.1 The proposed lots are not located on PS10 – This Bushfire Hazard Assessment and
maintained by: land that is subject to Medium or High Bushfire Management Plan has been prepared to
Hazard on overlay maps OM1.4-OM9.4; maintain the safety of people and property
a) Locating house site areas and other
from the adverse impacts of bushfire. The
sensitive uses on that part of the land least OR
majority of building envelopes are sited on
affected by the bushfire hazard; and
land not encumbered by Medium or High
S10.2 The proposed lots are sited on land
b) fire mitigation methods are used that are Bushfire Hazard areas on overlay maps
determined as low bushfire risk by a site-
adequate for the Potential Bushfire Hazard OM1.4-OM9.4;
specific bushfire hazard assessment.
rating of the individual site, having regard to –
AND
i. vegetation type;
ii. slope; S10.3 Additional lots are not created where Post development the new road and individual
their only vehicular access route is through a allotment access routes are proposed to be
iii. aspect;
Medium or High Bushfire Hazard area shown flanked by cleared residential allotments
iv. on-site and off-site fire hazard implications on overlay maps OM1.4-OM9.4 hence the access routes will exhibit limited
of the development; risk of being constrained during a bushfire.
v. bushfire history;
vi. conservation values of the site; and
vii. ongoing maintenance.
Firebreaks and fire access tracks
O11 Firebreaks or fire access tracks S11.1 Firebreaks are provided by— PS11.1 Given the limited scale of hazardous
provide— vegetation identified adjacent to building
a) a cleared road reserve not less than 20m
envelopes within and adjacent to the site,
a) adequate access for fire fighting and other wide located around the perimeter of the
combined with the irregular topography