                                                              FIRE MANAGEMENT REPORT FM 5601




       PO7                         AO.7
       Lot design and building     Each residential lot:
       siting minimises bushfire         (a) Includes a building          Complies
       hazard risk to people and             envelope, identified on
       property                              the plan of subdivision;
                                         (b) Is of sufficient size and    Access complies with “Fire
                                             shape to allow for           Hydrant and Vehicle Access
                                             efficient emergency          Guidelines for Residential,
                                             access to buildings for      Commercial and Industrial Lots”
                                             firefighting appliances      published by QFES and Qld
                                             (e.g., by avoiding battle-   Government.
                                             axe/hatchet lots and long
                                             narrow lots with long
                                             access driveways to
                                             buildings
                                         (c) Where more than              Complies
                                             2500m2 , achieves
                                             setbacks from hazardous
                                             vegetation in line with
                                             Bushfire Attack Level 29
                                             requirements as per AS
                                             3959; and
                                         (d) Is designed so that          Complies
                                             buildings and structures
                                             are sited in locations of
                                             lowest hazard within the
                                             lot and elements of the
                                             development least
                                             susceptible to fire are
                                             closest to the fire hazard
       PO8                         AO8.1
       Firebreaks and fire         Where development involves the         The site does not immediately
       access tracks provide:      creation of a new road and lots, a     adjoin threat vegetation with
            (a) Adequate           fire break is provided by providing    roads to the west and south
                access for         a cleared road reserve not less        providing access between
                firefighting and   than 20 metres wide and                adjoining site and threat
                other              maximum gradient of 12.5%              vegetation
                emergency          around the perimeter of the
                vehicles; and      subdivision, between the created
            (b) Adequate           lots and surrounding vegetated
                access for the     lands.
                evacuation of
                residents and      OR
                emergency
                personnel in an    AO8.2
                emergency          Fire access tracks are provided        N/A
                situation          between the created lots and           See comments above
                                   surrounding vegetated land that;
                                        (a) Have a cleared minimum
                                            width of 6m
                                        (b) Have a maximum
                                            gradient of 12.5%




ELDON BOTTCHER ARCHITECT PTY LTD                   ©             15/06/22                            42
Log in to download the original file

FMP 11C CHURCH STREET POMONA -1.pdf · 137 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.