Minor Change Existing Approval - MCU21 0158 02 (As Published)

of 8

Page text shows just the words. Original shows the document exactly as it was published.

                      Fencing and Walls
               8.     Any street fencing must be set back an average of 50mm from the front property boundary.
                      Any fencing on the front boundary must either:
                      a.      not exceed a maximum height of 2m
                      b.      be of open construction.
               9.     The area of land between the fence and the front property boundary must be densely
                      landscaped to screen any fencing from the stree.t
                      Clothes Drying Areas
               10.    Each dwelling unit must be provided with access to an outdoor clothesline which is screened
                      from public view.
                      Building Height
               11.    The maximum height of the development must not exceed 8.7 meters (RL 10.07 AHD) above
                      the finished ground level and the natural ground level as detailed on Plan DA5307 Rev D.
               12.    Certification must be submitted to Council from a Licensed Surveyor which certifies that the
                      buildings do not exceed the maximum height requirement of this Decision Notice.
                      Performance Bond
               13.    Security in the form of a cash bond or trading bank guarantee to the sum of $10,000 must
                      be submitted to Council, to secure performance of all conditions of this approval, prior to the
                      issue of a Development Permit for Operational Works. The cash bond or trading bank
                      guarantee will be returned on performance of the conditions of approval less any costs
                      incurred by Council in respect of enforcing performance of this permit. Council reserves the
                      right to call upon the bond or guaranteed sum to effect compliance with conditions.
                      Landscaping Works
               14.    The development site must be landscaped. The works must be undertaken in accordance
                      with an Operational Works approval and the Noosa Plan 2020 in particular PSP2 -
                      Landscaping for that specific area and must include in particular:
                      14.1. the works shown on the Approved Plans;
                      14.2. landscape plantings along the rear boundary of the site
                      14.3. a 500mm landscaping buffer strip along side boundaries of the subject site adjacent to
                            the entrance deck and entry walkway in accordance with the approved plans and
                            conditions of approval for the duration of the use;
                              i. The buffer strip should include species that will provide an effective buffer for
                                 maintaining privacy of adjoining uses.
               15.    All landscape works must be established and maintained in accordance with the approved
                      design for the life of the development, and in a manner that ensures healthy, sustained and
                      vigorous plant growth. All plant material must be allowed to grow to full form and be
                      refurbished when its life expectancy is reached.
               16.    All landscape works must be maintained generally in accordance with the approved design
                      for the life of the development.
                      Water & Sewer Connections
               17.    An underground connection to reticulated water and sewerage must be provided to the
                      ddevelopment site in accordance with the standards and requirements of Northern SEQ
                      Distributor–Retailer Authority (Unitywater).
               18.    A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority (Unitywater)
                      must be submitted to Council that certifies an underground connection to reticulated water
                      and sewerage has been provided to the development site.



                                                                                                        Page 3 of 8
Document Set ID: 23927329
Version: 4, Version Date: 14/07/2025
Log in to download the original file

Minor Change Existing Approval - MCU21 0158 02 (As Published).pdf · 161 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.