Original source · versioned page text
Minor Change Existing Approval - MCU21 0158 02 (As Published)
Damage to Services and Assets
30. Any damage caused to existing services and assets as a result of the development works
must be repaired at no cost to the asset owner at the following times:
a. where the damage would cause a hazard to pedestrian or vehicle safety, immediately;
or
b. where otherwise, upon completion of the works associated with the development.
Any repair work which proposes to alter the alignment or level of existing services and assets
must first be referred to the relevant service authority for approval.
Stormwater Drainage
31. Stormwater runoff from the development must be disposed of on-site without causing scour
or damage to the subject site or any adjoining property.
Stormwater Quality
32. A stormwater quality treatment system must be provided for the development. The works
must be undertaken in accordance with an Operational Works approval and must include in
particular stormwater quality treatment devices of a size and location generally in accordance
with those shown in drawing Drawing Number C10, titled ‘Stormwater Drainage Plan’,
prepared by RECOR dated 08/11/2021.
33. All primary stormwater quality treatment devices must be routinely checked, serviced and
cleaned in accordance with the manufacturer’s recommendations. Records of all
maintenance activities undertaken must be kept and made available to Council upon request.
Flood Immunity
34. The minimum finished floor level of all buildings constructed on the site must be in
accordance with the Approved Plans.
Flood Resilience and Flood Storage
35. The building structures (apart from the carports) are to be provided as pole construction, with
the underside of the building set above the 1%AEP flood level at year 2100 (the DFE). The
building undercroft is to remain open and able to function to provide floodplain storage during
a flood event. All building components located below the DFE, such as the building piers and
stairs, are to be designed and constructed to be resilient to the effects of flood water and
minimise loss of floodplain storage. Fencing located below the DFE is to be designed to allow
the free passage of flood waters, with the design details provided with the development
application for Operational Works (Landscaping).
5. REFERRAL AGENCIES
Not applicable.
6. ADVISORY NOTES
The following notes are included for guidance and information purposes only and do not form part
of the assessment manager conditions:
PLANNING
Aboriginal Cultural Heritage Act 2003
1. There may be a requirement to establish a Cultural Heritage Management Plan and/or obtain
approvals pursuant to the Aboriginal Cultural Heritage Act 2003 (ACH Act).
The ACH Act establishes a cultural heritage duty of care which provides that: “A person who
carries out an activity must take all reasonable and practicable measures to ensure the
activity does not harm Aboriginal cultural heritage”. It is an offence to fail to comply with the
duty of care. Substantial monetary penalties may apply to individuals or corporations
breaching this duty of care. Injunctions may also be issued by the Land and Resources
Tribunal, and the Minister administering the ACH Act can also issue stop orders for an activity
Page 5 of 8
Document Set ID: 23927329
Version: 4, Version Date: 14/07/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.