Appendix 8. A drawing with turning paths will be provided showing a vehicle able to turn around using space 30. At the end of the blind aisle, the aisle is only extended 0.7m as opposed to the required 1.0m as per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking. However 0.7m is considered sufficient as the aisle is relatively wide at 6.9m allowing sufficient space for a vehicle to reverse out of the space, clear of the vehicle parked to its right, before needing to turn. This is shown to work with turning paths shown in Drawing C3694-004, Appendix B. 2.2.2 Response to Point 5.2 As per AS 2890.1:2004 Parking facilities, Part 1: Off-street car parking the minimum ramp widths on the straights should be 5.5m. On the curves lane widths should be 3.9m with a central median of 0.6m giving a total width of 8.4m. Ramp widths on the straight at the top of the ramp will be approximately 5.6-5.9m, which complies with the standards. However, due to the physical restraints of the site, the widths on the curve of the ramp will be approximately 6.5-7.3m without a central median. However, as shown on Drawing C3694-004, Appendix B, there is sufficient space for a B85 and B99 vehicle to pass without conflicts on the ramp, as per AS 2890. 1:2004 Parking facilities, Part 1: Off-street car parking, Section 2.5.2(c). As shown in Drawing C3694-004, there will be conflicts on the straights where vehicles need to use the full width to negotiate the ramp, however this is considered adequate, as there is full vision for oncoming vehicles. Although the site does not qualify as a domestic property, the basement will only be used by employees and their clients and will not be open to the general public. Therefore traffic entering and exiting will be low and conflicts on the ramp would be rare. We could expect 18 trips to and from the basement in the peak hours. Assuming a 60/40 % split for in and out would mean 12 vehicles entering (1 every 5 minutes) and 6 vehicles exiting (1 every 10 minutes) or vice versa. Therefore there would be a low chance of opposing vehicles being on the ramp at the same time. Measures will also be undertaken to ensure the chance of conflict to opposing vehicles it kept to a minimum. These are: - Mirrors will be provided on walls at the ramp curve to allow vehicles to see if there is another coming vehicle. - Signage will be provided saying "Watch for Oncoming Vehicles” and "Keep Left". - Centre line marking will also be provided on the ramp to keep traffic as far to the left as possible. Ramp grades discussed in Section 4.1.1. Repo No. 4530-0 VPM. BURCHILL VDM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/2689 - Response to request for further Information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 19.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.